YS/T 539.13-2009 English PDFYS/T 539.13: Historical versions
Basic dataStandard ID: YS/T 539.13-2009 (YS/T539.13-2009)Description (Translated English): Methods for chemical analysis of nickel base alloy powder. Part 13: Determination of oxygen content. The pulse heating inert gas fusion-infrared absorption method Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H71 Classification of International Standard: 77.120.40 Word Count Estimation: 4,456 Date of Issue: 2009-12-04 Date of Implementation: 2010-06-01 Older Standard (superseded by this standard): YS/T 539.13-2006 Regulation (derived from): MIIT [2009] No. 66 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies: Determination of oxygen content nickel-base alloy powder. This standard applies to the oxygen content of the nickel -base alloy powder measurement, measuring range: 0. 005% to 0. 2 %. YS/T 539.13-2009: Methods for chemical analysis of nickel base alloy powder. Part 13: Determination of oxygen content. The pulse heating inert gas fusion-infrared absorption method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of nickel base alloy powder.Part 13. Determination of oxygen content.The pulse heating inert gas fusion-infrared absorption method ICS 77.120.40 H71 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 539.13-2006 Nickel-based alloy powder chemical analysis Determination of oxygen. Part 13 The pulse heating inert gas fusion - infrared absorption method Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 539 "nickel-based alloy powder chemical analysis method" is divided into 13 parts as follows. --- Part 1. Determination of the amount of boron in the titration; --- Part 2. Determination of the amount of chrome aluminum Azure S Spectrophotometry; --- Part 3. Determination of silicon content of perchloric acid dehydration gravimetric method; --- Part 4. Determination of chromium content of ammonium persulfate oxidation titration; --- Part 5. Determination of manganese content of sodium periodate (K) oxidation spectrophotometry; --- Part 6. Determination of iron content of titanium trichloride - potassium dichromate titration; --- Part 7. Determination of cobalt content nitroso R salt spectrophotometric method; --- Part 8. Determination of copper content Neocuproine - chloroform extraction spectrophotometric method; --- Part 9. Determination of copper content of sodium thiosulfate iodometry; --- Part 10. Determination of molybdenum content - Thiocyanate spectrophotometric method; --- Part 11. Determination of cinchonine gravimetric method tungsten content; --- Part 12. Determination of phosphorus content of n-butyl alcohol - chloroform extraction spectrophotometric method; --- Part 13. Determination of oxygen pulse heating inert gas fusion - infrared absorption method. This section is YS/T Part 13 539. The partial replacement of YS/T 539.13-2006 "nickel-based alloy powder chemical analysis of pulse heating inert gas fusion coulometric titration Determination of oxygen. " This portion of YS/T 539.13-2006 phase comparator major changes are as follows. --- The coulometric titration method to the infrared absorption method; --- Increasing the foreword; --- Complements the repeatability limit. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This section is responsible for drafting unit. Beijing Nonferrous Metal Research Institute, China Nonferrous Metals Industry Institute of Standards and Metrology and Quality. This section is drafted. Beijing Nonferrous Metal Research Institute, Steel Research Institute. The main drafters of this section. Zhou Hai income, Wang Hongbin, Song Xiao force. This part of the standard replaces the previous editions are. --- GB/T 8638.13-1988; --- YS/T 539.13-2006. Nickel-based alloy powder chemical analysis Determination of oxygen. Part 13 The pulse heating inert gas fusion - infrared absorption method1 ScopeYS/T 539 This part specifies the method for determination of nickel-base alloy powder oxygen content. This section applies to the determination of nickel-base alloy powder oxygen content measurement range. 0.005% to 0.2%.2 Method summaryUnder an inert atmosphere, the graphite crucible sample is heated and melted by the pulse and oxygen in a sample in the form of carbon monoxide precipitation, precipitation CO contained in the inert gas taken off, copper oxide by oxidation of carbon monoxide to carbon dioxide will be produced, enters the infrared detector to measure the oxygen content.3 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 Metal foil. nickel foil (Ni≥99.9%) or tin capsules (Sn≥99.9%), oxygen content (O≤0.0050%); nickel foil before use applications CTC dip cotton scrub, cut the same size, the size quite small, dry and set aside. 3.2 CTC. 3.3 Helium (volume fraction ≥99.99%). 3.4 graphite crucible. sets of spectral pure graphite crucible. 3.5 Sample. choose between standard steel 0.0050% to 0.20% oxygen mass fraction. 3.6 magnesium perchlorate and alkali asbestos (chemically pure).4 InstrumentPulse heating infrared analyzer. --- Pulse furnace. temperature greater than 2000 ℃; --- Detector sensitivity. 0.01μg/g. Step 5 Analysis 5.1 Sample When the content of oxygen in the sample O≤0.02%, a sample was weighed 0.15g ~ 0.25g, accurate to 0.001g; when the content of oxygen in the sample O > At 0.02%, a sample was weighed 0.10g ~ 0.20g, accurate to 0.001g. Sample with 1.0g (accurate to 0.001g) metal foil (3.1) package. 5.2 Determination of the number of Independent of the two measurements, the mean value. 5.3 warmed up Required equipment specification, switch on the instrument, and preheating system checks. 5.4 Calibration Blank 5.4.1 Open pulse furnace, the crucible (3.4) placed under electrodes, 1.0g (accurate to 0.0001g) metal foil (3.1), placed in sample loading Inside. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 539.13-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 539.13-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 539.13-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 539.13-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 539.13-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 539.13-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |