YS/T 520.6-2007 English PDFUS$199.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 520.6-2007: Chemical analysis of gallium. Part 6: Determination of tin content. The salicylfluorone cetylrimethylammonium bromide spectrophotometric method Status: Valid YS/T 520.6: Historical versions
Basic dataStandard ID: YS/T 520.6-2007 (YS/T520.6-2007)Description (Translated English): Chemical analysis of gallium. Part 6: Determination of tin content. The salicylfluorone cetylrimethylammonium bromide spectrophotometric method Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H14 Classification of International Standard: 77.120.70 Word Count Estimation: 6,677 Date of Issue: 2007-11-14 Date of Implementation: 2008-05-01 Older Standard (superseded by this standard): YS/T 520.6-2006 Regulation (derived from): NDRC Notice No. 77 of 2007 Issuing agency(ies): National Development and Reform Commission Summary: This standard specifies the gallium Determination of tin content. This standard applies to the determination of tin in gallium. Measuring range: 0. 00005% to 0. 020% YS/T 520.6-2007: Chemical analysis of gallium. Part 6: Determination of tin content. The salicylfluorone cetylrimethylammonium bromide spectrophotometric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Chemical analysis of gallium.Part 6. Determination of tin content.The salicylfluorone cetylrimethylammonium bromide spectrophotometric method ICS 77.120.70 H14 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 520.6-2006 Chemical analysis of gallium Determination of tin content. Part 6 Salicylfluorone - cetyl trimethyl ammonium bromide Posted 2007-11-14 2008-05-01 implementation National Development and Reform Commission issued ForewordYS/T 520-2007 "Chemical analysis of gallium" Is the YS/T 520-2006 (formerly GB/T 4375-1984) amendments, divided into Part 12. --- Part 1. Determination of copper content of 2,9-dimethyl-4,7-diphenyl-1,10-phenanthroline spectrophotometry --- Part 2. Determination of lead content of 4- (2-pyridyl) - resorcinol spectrophotometry --- Part 3. Determination of aluminum content Chromazurol S- tetradecyl pyridine bromide spectrophotometric method --- Part 4. Determination of iron content of 4,7-diphenyl-1,10-phenanthroline spectrophotometry --- Part 5. Determination of calcium content nitrous oxide - acetylene flame atomic absorption spectrometry --- Part 6. Determination of tin content salicylfluorone - cetyl trimethyl ammonium bromide, spectrophotometry --- Part 7. Determination of silicon content extraction - molybdenum blue spectrophotometric method --- Part 8. Determination of indium content of ethyl violet spectrophotometry --- Part 9. Determination of germanium content Phenylfluorone - polyethylene glycol octyl phenyl ether extraction spectrophotometric method --- Part 10. Determination of zinc content atomic absorption spectrometry --- Part 11. Determination of mercury content of the cold atomic absorption spectrometry --- Part 12. lead, copper, nickel, aluminum, indium and zinc Determination of chemical spectroscopy Part is divided into 6 sections. The partial replacement of YS/T 520.6-2006 (formerly GB/T 4375.6-1984). This part is YS/T 520.6-2006 "Chemical analysis of gallium - Part 6. Determination of tin content salicylfluorone - bromide Cetyl trimethyl ammonium spectrophotometry "editorial finishing. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This standard by the Aluminum Corporation of China Shandong branch responsible for drafting. Drafters of this section. Chen Jianli, Wang Li set, Qi Yanli, Tian Rui. The non-ferrous metal part by the National Standardization Technical Committee responsible for the interpretation. This part of the standard replaces the previous editions are. --- YS/T 520.6-2006 (formerly GB/T 4375.6-1984). Chemical analysis of gallium Determination of tin content. Part 6 Salicylfluorone - cetyl trimethyl ammonium bromide Spectrophotometry1 ScopeThis section provides the determination of tin content in gallium. This section applies to the determination of tin content in gallium. Measurement range. 0.00005% to 0.020%.2 Method summarySample with nitric acid, sulfuric acid dissolution. Potassium iodide in 8mol/L sulfuric acid medium, to extract tin benzene, back-extracted with dilute sulfuric acid. Anti Ascorbic acid reduction of free iodine in 2mol/L sulfuric acid solution, tartaric acid as the catalyst, tin and salicylfluorone - cetyltrimethylammonium Ammonium form a yellow complex. 509nm wavelength spectrophotometer measured absorbance.3 Reagents3.1 benzene. 3.2 nitrate (ρ1.42g/cm 3), pure class distinctions. 3.3 sulfate (ρ1.84g/cm 3), pure class distinctions. 3.4 sulfuric acid (1 + 1), pure class distinctions. 3.5 sulfuric acid (1 + 4), pure class distinctions. 3.6 sulfuric acid (1 + 24), pure class distinctions. 3.7 sulfuric acid (1 + 49), pure class distinctions. 3.8 potassium iodide solution (500g/L). 3.9 ascorbic acid solution (100g/L). 3.10 tartaric acid solution (200g/L). 3.11 salicylfluorone solution (0.3g/L). Weigh 0.09g salicylfluorone dissolved in 180mL of ethanol and 0.5mL of sulfuric acid (3.4), diluted with water to 300mL, stored in a brown bottle and set aside. 3.12 cetyl trimethyl ammonium bromide solution. Weigh 1.82g cetyl trimethyl ammonium bromide, dissolved in water and diluted to 500mL. 3.13 Storage tin standard solution. Weigh 1.0000g pure tin [(Sn) ≥99.99%], placed in 300mL beaker, add 50mL sulfur Acid (3.3), dissolved by heating and cooling. With sulfuric acid (3.5) and the solution was transferred to 1000mL volumetric flask and dilute to volume, and mix. This solution 1mL containing 1.0mg tin. 3.14 tin standard solution. Pipette 25.00mL tin standard stock solution (3.13) was placed in 250mL volumetric flask, dilute sulfuric acid (3.7) to Volume, and mix. This solution 1mL containing 100μg tin. 3.15 tin standard solution. Pipette 25.00mL tin standard solution (3.14) into 250mL volumetric flask, dilute to the mark with sulfuric acid (3.7) Degree, and mix. 1mL containing 10μg solution tin.4 InstrumentSpectrophotometer. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 520.6-2007_English be delivered?Answer: Upon your order, we will start to translate YS/T 520.6-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 520.6-2007_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 520.6-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 520.6-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 520.6-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |