YS/T 519.2-2009 English PDFUS$169.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 519.2-2009: Methods for chemical analysis of arsenic. Part 2: Determination of antimony content. Malachite green spectrophotometric method Status: Valid YS/T 519.2: Historical versions
Basic dataStandard ID: YS/T 519.2-2009 (YS/T519.2-2009)Description (Translated English): Methods for chemical analysis of arsenic. Part 2: Determination of antimony content. Malachite green spectrophotometric method Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H17 Classification of International Standard: 77.120.99 Word Count Estimation: 6,655 Date of Issue: 2009-12-04 Date of Implementation: 2010-06-01 Older Standard (superseded by this standard): YS/T 519.2-2006 Regulation (derived from): MIIT [2009] No. 66 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the amount of antimony arsenic determination. This standard applies to the determination of the amount of antimony arsenic. Measuring range: 0. 01% to 0. 45%. YS/T 519.2-2009: Methods for chemical analysis of arsenic. Part 2: Determination of antimony content. Malachite green spectrophotometric method---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of arsenic.Part 2. Determination of antimony content.Malachite green spectrophotometric method ICS 77.120.99 H17 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 519.2-2006 Methods for chemical analysis of arsenic Part 2. Determination of antimony content Malachite Green Spectrophotometry Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 519-2009 "chemical analysis of arsenic" is divided into four parts. --- Part 1. Determination of arsenic content potassium bromate titration; --- Part 2. Determination of antimony content - Malachite green spectrophotometry; --- Part 3. Determination of sulfur content of barium sulfate gravimetric method; --- Part 4. bismuth, antimony, sulfur content - Inductively coupled plasma atomic emission spectrometry. This section YS/T 519 Part 2. The partial replacement of YS/T 519.2-2006 (formerly GB/T 4373.2-1984) "Methods for chemical analysis of arsenic malachite green spectrophotometry Determination of antimony content. " Compared with YS/T 519.2-2006, this section has the following changes. --- Sample size proposed new requirements, the specimen shall be subject to an 80-mesh sieve, diameter of not more than 2mm, to sample all through 0.84mm sieve, and then 0.42mm sieve; --- Symmetry like proportions were modified by the press on the screen and under the screen ratio of 3 Weigh, modify according to the actual proportion sieve weighed; --- Text format has been modified; --- Complements the precision, quality assurance and control provisions. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This section is responsible for drafting unit. Hunan Nonferrous Metals Group Co., Ltd. Shuikoushan. Participated in the drafting of this section. Zhuzhou Smelter Group Co., Ltd., Hunan Nonferrous Metal Research Institute. The main drafters of this section. Tanping Sheng, Tan Qian, Lu Chunyan, Ling were dry, Binbin, Cai Jun, Liu Yan, Pang Wenlin, John Doe red. This part of the standard replaces the previous editions are. --- GB/T 4373.2-1984; --- YS/T 519.2-2006. Methods for chemical analysis of arsenic Part 2. Determination of antimony content Malachite Green Spectrophotometry Warning. Arsenic and its compounds are toxic substances, disposal of contact and need special care.1 ScopeYS/T 519 This part specifies the determination of arsenic in antimony content. This section applies to the determination of arsenic in antimony content. Measuring range. 0.01 to 0.45%.2 Method summaryThe sample was dissolved by heating with sulfuric acid after evaporation to near dryness, dissolved in hydrochloric acid and transferred to a volumetric flask, pipette part test solution in a separating funnel, first with chlorine Stannous reduction, then sodium nitrite oxidation to pentavalent antimony at about 1.5mol/L hydrochloric acid solution was added malachite green, extracted with benzene, The organic phase was measured in a spectrophotometer at a wavelength of 625nm absorbance obtained antimony content.3 ReagentsAnalysis process unless otherwise specified, all reagents and analytical use distilled water or water of equivalent purity. 3.1 sulfuric acid. Hydrochloride 3.2 (2 + 1). 3.3 sodium nitrite solution (100g/L). 3.4 urea solution (500g/L). 3.5 stannous chloride solution (100g/L). Weigh 10g of stannous chloride, 250mL beaker is placed, was added 67mL of hydrochloric acid (ρ1.19g / mL) dissolved and transferred to 100mL dropper bottle, dilute with water to 100mL, and mix (available in one to two weeks). 3.6 malachite green solution (1g/L). Weigh 0.10g malachite green, placed in 150mL beaker, was added 50mL of ethanol, 50mL water to dissolve Solution, filtered in a brown bottle, and mix. 3.7 Antimony standard stock solution. Weigh 0.5000g metal antimony (Sb≥99.99%), placed in 250mL beaker, add 10mL sulfuric acid (3.1), cover the surface of the dish, the heating furnace is set to dissolve completely, and heating continued to take fuming sulfuric acid and the solution was evaporated to a volume of about 2mL, remove the cold To room temperature, add a small amount of hydrochloric acid (3.2) dissolved salts and into 1000mL volumetric flask with hydrochloric acid (3.2) and Beibi purged dish surface, incorporated Volumetric flask, diluted with hydrochloric acid (3.2) to the mark, and mix the solution 1mL containing 0.5mg antimony. 3.8 Antimony standard solution (0.004mg/mL). Pipette 4.00mL antimony standard stock solution (3.7) in 500mL volumetric flask, hydrochloride (3.2) diluted to the mark, mix 1mL solution containing 4μg antimony. 3.9 benzene.4 InstrumentSpectrophotometer.5 SampleThe sample was processed into all over the 0.84mm sieve-like crumbs, and then 0.42mm sieve, the sample points sieve, sieve, respectively, into grinding mouth Bottle, sealed with paraffin. Processing should prevent overheating oxidation. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 519.2-2009_English be delivered?Answer: Upon your order, we will start to translate YS/T 519.2-2009_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 519.2-2009_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 519.2-2009_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 519.2-2009?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 519.2-2009 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |