Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 514.9-2024 English PDF

YS/T 514.9: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 514.9-2024RFQ ASK 3 days (Chemical analysis methods for high titanium slag and rutile - Part 9: Impurity elements content Determination of the content of impurities - Inductively coupled plasma atomic emission spectrometry) Valid
YS/T 514.9-2009279 Add to Cart 3 days Methods for chemical analysis of high-titanium slag and rutile. Part 9: Determination of clacium oxide, magnesium oxide, manganese monoxide, phosphorus, chromic oxide and vanadium pentoxide content. Inductively coupled plasma atomic emission spectromerty Obsolete
YS/T 514.9-2006199 Add to Cart 2 days Methods for chemical analysis of high-titanium slag and rutile The persulfate oxidation-arsenite volumetric method for the determination of manganous monoxide content Obsolete


Basic data

Standard ID: YS/T 514.9-2024 (YS/T514.9-2024)
Description (Translated English): (Chemical analysis methods for high titanium slag and rutile - Part 9: Impurity elements content Determination of the content of impurities - Inductively coupled plasma atomic emission spectrometry)
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H14
Classification of International Standard: 77.120.50
Date of Issue: 2024-10-24
Date of Implementation: 2025-05-01
Older Standard (superseded by this standard): YS/T 514.9-2009
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This standard specifies the method for determining the content of impurity elements in high-titanium slag and rutile by inductively coupled plasma atomic emission spectrometry. This standard is applicable to the determination of impurity element content in high-titanium slag and rutile.

YS/T 514.9-2009: Methods for chemical analysis of high-titanium slag and rutile. Part 9: Determination of clacium oxide, magnesium oxide, manganese monoxide, phosphorus, chromic oxide and vanadium pentoxide content. Inductively coupled plasma atomic emission spectromerty



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Methods for chemical analysis of high-titanium slag and rutile.Part 9. Determination of clacium oxide, magnesium oxide, manganese monoxide, phosphorus, chromic oxide and vanadium pentoxide content.Inductively coupled plasma atomic emission spectromerty ICS 77.120.90 H14 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 514.10 ~ 514.11-2006 High titanium slag and rutile chemical analysis Part 9. calcium oxide, magnesium oxide, manganese oxide, phosphorus, Determination of chromium oxide and vanadium pentoxide amount Inductively Coupled Plasma Atomic Emission Spectrometry Posted 2009-12-04 2010-06-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 514 "high titanium slag and rutile chemical analysis method" is divided into 10 parts. --- Part 1. Determination of titanium dioxide content of ammonium ferric sulfate titration; --- Part 2. Determination of total iron content of dichromate method; --- Part 3. Determination of sulfur content of high frequency infrared absorption method; --- Part 4. Determination of the amount of silica weighing method, the molybdenum blue spectrophotometric method; --- Part 5. aluminum oxide content - EDTA titration; --- Part 6. Determination of a manganese oxide content by flame atomic absorption spectrometry; --- Part 7. calcium oxide, magnesium oxide content - Flame atomic absorption spectrometry; --- Part 8. Determination of the amount of phosphorus antimony molybdenum blue spectrophotometric method; --- Part 9. calcium oxide, magnesium oxide, manganese oxide, phosphorus, chromium oxide and vanadium pentoxide content - Inductively coupled plasma Daughters emission spectrometry; --- Part 10. Determination of the amount of carbon frequency infrared absorption method. This section YS/T Section 9514 of. The partial replacement of YS/T 514.10-2006 "high titanium slag and rutile chemical analysis of carbon diphenyl acid dihydrazide spectrophotometric determination of ozone The amount of chromium ", YS/T 514.11-2006" high titanium slag and rutile chemical analysis of benzoyl phenylhydroxylamine extraction spectrophotometric determination pentoxide Vanadium content. " This portion of YS/T 514.10 ~ 514.11-2006 compared to the main changes are as follows. --- By inductively coupled plasma (ICP-AES method) simultaneous determination of high titanium slag and rutile in the calcium oxide, magnesium oxide, Manganese, phosphorus, chromium oxide and vanadium pentoxide amount; --- Platinum crucible sand bath plus hydrofluoric acid, perchloric acid dissolved titanium slag samples; microwave digestion dissolve rutile samples; --- Increasing the repeatability limit and quality assurance and control provisions. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This section is responsible for drafting unit. Zunyi Titanium Co., Ltd., China Nonferrous Metals Industry Standards and Metrology Institute for Quality. Participated in the drafting of this section. Jinchuan Group Co., Ltd. Fushun Titanium. The main drafters of this section. Qu Wei Xin, Yang Xue new to London strong, Yu Shengjie, Zhuang Jun, Ma Yuping. This part of the standard replaces the previous editions are. --- GB/T 4102.10-1983, GB/T 4102.11-1983; --- YS/T 514.10-2006, YS/T 514.11-2006. High titanium slag and rutile chemical analysis Part 9. calcium oxide, magnesium oxide, manganese oxide, phosphorus, Determination of chromium oxide and vanadium pentoxide amount Inductively Coupled Plasma Atomic Emission Spectrometry

1 Scope

YS/T 514 This part provides high titanium slag and rutile calcium oxide, magnesium oxide, manganese oxide, phosphorus, chromium trioxide and pentoxide Determination of vanadium content. This section applies to high titanium slag, calcium oxide, magnesium oxide manganese, phosphorus, chromium oxide and vanadium pentoxide measured amount of rutile. Measurement range. calcium oxide. 0.10% to 5.0%; MgO. 0.10% to 5.0%; a manganese oxide. 0.10% ~ 5.0%; P. 0.001% ~ 0.30%; chromium oxide. 0.01% to 1.5%; vanadium pentoxide. 0.01% to 1.5%.

2 Method summary

High titanium slag sample in a platinum crucible with perchloric acid, hydrofluoric acid to dissolve and heated to take strong perchlorate smoke. Removed, acid-soluble salt coolish Solutions of salts. Rutile sample to digestion tank with nitric acid, hydrofluoric acid dissolved and diluted to volume. Under certain conditions, Inductively Coupled Plasma emission spectrometer, at the recommended analytical line emission intensity measured at a wavelength of Ca, Mg, Mn, P, Cr, V and other elements, according to the working curve Calculation sample amount of calcium oxide, magnesium oxide, manganese oxide, phosphorus, chromium oxide and vanadium pentoxide, mass fraction shows the measurement results.

3 Reagents

Unless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water or equivalent purity. 3.1 hydrofluoric acid (ρ about 1.15g/mL). 3.2 perchloric acid (ρ about 1.76g/mL). 3.3 hydrochloric acid (ρ about 1.19g/mL). 3.4 nitric acid (ρ about 1.40g/mL). 3.5 sulfate (1 + 1). 3.6 Sodium hydroxide solution (100g/L). 3.7 HCl (1 + 1). 3.8 Calcium standard stock solution. Weigh 0.2497g of calcium carbonate (GR, pre-bake at 105 ℃ 1h after cooling to room temperature) was placed in 300mL burn Cup, add water 20mL, was added dropwise hydrochloric acid (3.3) until completely dissolved, then the excess 10mL, boiled to remove CO2, cooling capacity is transferred to 100mL Bottle diluted with water to the mark. This solution 1mL containing 1.0mg of calcium. 3.9 Magnesium standard stock solution. Weigh 0.1000g of magnesium (mass fraction ≥99.99%), dissolved in 20mL hydrochloric acid (3.7). Moved 100mL volumetric flask. Dilute with water to volume, and mix. This solution 1mL containing 1.0mg of magnesium. 3.10 Manganese standard stock solution. Weigh 0.1000g of manganese metal (mass fraction ≥99.99%), (3.5) dissolved in sulfuric acid 50mL, transferred 100mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 1.0mg of manganese. 3.11 P standard stock solution. Weigh 0.43937g reference reagent potassium dihydrogen phosphate (previously at 105 ℃ ~ 110 ℃ drying 2h, and placed Dryer cooling to room temperature), placed in 200mL beaker, add water, dissolved and transferred to 100mL volumetric flask, dilute to the mark with water, mix uniform. This solution 1mL containing 1.0mg phosphorus. 3.12 chromium standard stock solution. Weigh 0.2829g reference reagent potassium dichromate (pre-bake at 150 ℃ 1h, adding to constant weight) to an aqueous After the solution transferred to 100mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 1.0mg of chromium.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 514.9-2024_English be delivered?

Answer: Upon your order, we will start to translate YS/T 514.9-2024_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 514.9-2024_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 514.9-2024_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YS/T 514.9-2024?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 514.9-2024 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.