Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 509.4-2008 PDF English

US$150.00 · In stock · Download in 9 seconds
YS/T 509.4-2008: Methods for chemical analysis of spodumene and lepidolite concentrates. Determination of aluminium oxide content. EDTA compleximetric method
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure

YS/T 509.4: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
YS/T 509.4-2008150 Add to Cart Auto, 9 seconds. Methods for chemical analysis of spodumene and lepidolite concentrates. Determination of aluminium oxide content. EDTA compleximetric method  
YS/T 509.4-2006199 Add to Cart 2 days Methods for chemical analysis of spodumenite and lepidolite concentrates The EDTA volumetric method for the determination of aluminum oxide content Obsolete

Similar standards

GB/T 2524   GB/T 3620.1   YS/T 509.11   

YS/T 509.4-2008: Methods for chemical analysis of spodumene and lepidolite concentrates. Determination of aluminium oxide content. EDTA compleximetric method


---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/YST509.4-2008
YS NONFERROUS METALS INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA ICS 77.120.99 H 64 Replacing YS/T 509.4-2006 Methods for chemical analysis of spodumene and lepidolite concentrates - Determination of aluminum oxide content - EDTA compleximetric method ISSUED ON: MARCH 12, 2008 IMPLEMENTED ON: SEPTEMBER 1, 2008 Issued by: National Development and Reform Commission of China

Table of Contents

Foreword ... 3 1 Scope ... 5 2 Method summary ... 5 3 Reagents ... 5 4 Specimen ... 7 5 Analysis steps ... 7 6 Calculation of analysis result ... 8 7 Precision ... 9 8 Quality assurance and control ... 9

Foreword

YS/T 509 "Methods for chemical analysis of spodumene and lepidolite concentrates" consists of the following 11 parts: - Part 1: Determination of lithium oxide sodium oxide and potassium oxide contents - Flame atomic absorption spectrometric method; - Part 2: Determination of rubidium oxide and caesium oxide contents - Flame atomic absorption spectrometric method; - Part 3: Determination of silicon dioxide content - Gravimetric- molybdenum blue photometric method; - Part 4: Determination of aluminum oxide content - EDTA compleximetric method; - Part 5: Determination of ferric oxide content - O-phenanthroline photometric method and EDTA compleximetric method; - Part 6: Determination of phosphorus pentoxide content - The molybdenum blue photometric method; - Part 7: Determination of beryllium oxide content – Chromazurol S and cetyltrimethyl ammonium bromide spectrophotometric met; - Part 8: Determination of calcium oxide and magnesium oxide content - Flame atomic absorption spectrometric method; - Part 9: Determination of fluorine content - lon selective electrode method; - Part 10: Determination of manganous oxide content-Persulfate oxidation photometric method; - Part 11: Determination of loss on ignition - Gravimetric method. This Part is Part 4. This Part replaces YS/T 509.4-2006 "Methods for chemical analysis of spodumenite and lepidolite concentrates The EDTA volumetric method for the determination of aluminum oxide content" (previous edition is GB/T 3885.4- 1983). Compared with YS/T 509.4-2006, the main changes in this Part are as follows: - modified the titer (T) of lead standard solution and aluminum oxide to the concentration of the substance; Methods for chemical analysis of spodumene and lepidolite concentrates - Determination of aluminum oxide content - EDTA compleximetric method

1 Scope

This Part specifies the determination methods for aluminum oxide content in spodumene, lepidolite concentrates. This Part is applicable to the determination of aluminum oxide content in spodumene, lepidolite concentrates. Determination range: 10.00%~30.00%.

2 Method summary

The test material is melted with potassium hydroxide. Use water to leach. Pipette part of the solution. Add excessive EDTA. Boil complexed aluminum at pH5~pH6. Excessive EDTA uses xylenol orange as indicator. Use lead standard solution to back drip. Add fluoride. Use lead standard solution to titrate the released EDTA. Calculate the amount of aluminum oxide from the volume of lead standard solution consumed.

3 Reagents

Unless otherwise stated, only the confirmed analytically-pure reagents and distilled water or water of comparable purity are used in the analysis. 3.1 Potassium hydroxide. 3.2 Ammonium fluoride. 3.3 Absolute ethanol. 3.4 Hydrochloric acid (ρ1.19g/mL). 3.5 Ammonium hydroxide (1+1). 3.6 Ammonium hydroxide (1+19). 3.7 Buffer solution (pH5.5): Dissolve 120.5g of anhydrous sodium acetate in water. Add 10mL of glacial acetic acid. Transfer to a 1000mL volumetric flask. V1 - Volume of lead standard solution (3.10) consumed to titrate aluminum oxide, in milliliters (mL); V0 - Volume of lead standard solution (3.10) consumed to titrate blank solution, in milliliters (mL); 0.05098 - Amount of aluminum oxide equivalent to 1.00mL of lead standard solution [c(Pb)=1.0000mol/L], in grams per mole (g/mol). Conduct parallel calibration in triplicate. The extreme deviation value of the consumed lead standard solution (3.10) shall not exceed 0.05mL. Take the average value. Otherwise, recalibrate. 3.11 Bromophenol blue solution (1g/L). 3.12 Xylenol orange ethanol (1+1) solution (5g/L): Prepare when used.

4 Specimen

4.1 Spodumene concentrate shall pass through a sieve with an aperture of 0.074mm. Lepidolite concentrate shall pass through a sieve with an aperture of 0.105mm. 4.2 The specimen is pre-baked at 105°C~110°C for 2h. Place in a desiccator to cool to room temperature.

5 Analysis steps

5.1 Test material Weigh 0.25g of specimen, to the nearest of 0.0001g. 5.2 Number of determinations Make parallel determinations of two test materials. Take the average value. 5.3 Blank test Conduct blank test with test material. 5.4 Determination 5.4.1 Place the test material (5.1) in a 30mL silver crucible. Add 5 drops of absolute ethanol (3.3) to moisten. Add 4g of potassium hydroxide (3.1). Put the lid on the crucible and leave a little gap. Remove moisture on an electric stove. Place in 600°C~650°C high temperature furnace to melt for 10min~15min. Take ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of YS/T 509.4-2008 be delivered?Answer: The full copy PDF of English version of YS/T 509.4-2008 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of YS/T 509.4-2008_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 509.4-2008_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- YS/T 509.4-2008 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version YS/T 509.4-2008?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 509.4-2008 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of YS/T 509.4-2008?

A step-by-step guide to download PDF of YS/T 509.4-2008_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "YS/T 509.4-2008".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9