YS/T 3000-2010 English PDFUS$259.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 3000-2010: Activated carbon regenerator technical specification Status: Valid
Basic dataStandard ID: YS/T 3000-2010 (YS/T3000-2010)Description (Translated English): Activated carbon regenerator technical specification Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H90 Classification of International Standard: 77.180 Word Count Estimation: 10,125 Date of Issue: 2010-11-10 Date of Implementation: 2011-03-01 Quoted Standard: GB/T 191; GB/T 3797; GB/T 4064; GB/T 6388; GB 9078; GB/T 12496.22; GB/T 13306; GB/T 16618; GB/T 17195; JB/T 4711 Regulation (derived from): MIIT (2010) No. 126; industry standard filing Notice 2012 No. 5 (No. 149 overall) Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the technical performance of activated carbon regeneration furnace, process, technical requirements, test methods, inspection rules and signs, quality guarantee period, packaging, transport and storage. This standard applies to activated carbon regeneration furnace (hereinafter referred to as regenerative furnaces). YS/T 3000-2010: Activated carbon regenerator technical specification---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Activated carbon regenerator technical specification ICS 77.180 H90 People's Republic of China Gold Industry Standards Activated carbon regeneration furnace technical specifications Issued on. 2010-11-10 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordThe standard proposed by China Gold Association. This standard by the National Gold Standardization Technical Committee (SAC/TC379) centralized. This standard was drafted. Changchun Gold Research Institute. Drafters of this standard. Wu Ling, left Yuming, Xue Lixian, Li Zhehao Long the Serve Li Yanji, Zhang Wei, Zhu Zhang, Pei Zhang Hong, Fu Ximing, Tian Baoguo, down toward the positive. Activated carbon regeneration furnace technical specifications1 ScopeThis standard specifies the technical properties of activated carbon regeneration furnace, process, technical requirements, test methods, inspection rules and signs, quality assurance SFC, packaging, transport and storage. This standard applies to activated carbon regeneration furnace (hereinafter referred to as regenerators).2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 191 Packaging - Pictorial signs GB/T 3797 Electric Control Equipment GB/T 4064 electrical equipment safety design guidelines GB/T 6388 transport package shipping mark GB 9078 industrial furnace air pollutant emission standards GB/T 12496.22 wooden activated carbon testing methods for determination of strength GB/T 13306 product label GB/T 16618 General technical insulation of industrial furnaces GB/T 17195 Industrial Furnace Terminology JB/T 4711 Pressure vessel coated with transport packaging3 Terms and DefinitionsGB/T 17195 and defined by the following terms and definitions apply to this standard. 3.1 Activated carbon regeneration regenerationofactivatedcarbon The used adsorption capacity of less than granular activated carbon process requirements for processing, to restore its adsorption process activity. 3.2 Adsorption capacity adsorptioncapacity Activated carbon adsorption unit weight of dry matter specific maximum amount. 3.3 Adsorption capacity recovery rate recoveryrateofadsorptioncapacity Adsorption capacity recovery rate after regeneration carbon adsorption capacity and adsorption capacity of the new carbon ratio. which is. Adsorption Capacity recovery rate = Carbon adsorption capacity after regeneration The new carbon absorption capacity × 100% 3.4 Regeneration temperature regenerationtemperature Activated carbon regeneration operating temperature. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 3000-2010_English be delivered?Answer: Upon your order, we will start to translate YS/T 3000-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 3000-2010_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 3000-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |