Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 244.5-2008 English PDF

US$249.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 244.5-2008: Chemical analysis methods of high purity aluminium. Part 5: Determination of copper, zinc and lead content by anodic spripping voltammetric method
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 244.5-2008249 Add to Cart 3 days Chemical analysis methods of high purity aluminium. Part 5: Determination of copper, zinc and lead content by anodic spripping voltammetric method  

Similar standards

GB/T 7999   YS/T 600   GB/T 14849.2   YS/T 872   YS/T 420   YS/T 739.4   

Basic data

Standard ID: YS/T 244.5-2008 (YS/T244.5-2008)
Description (Translated English): Chemical analysis methods of high purity aluminium. Part 5: Determination of copper, zinc and lead content by anodic spripping voltammetric method
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H12
Classification of International Standard: 77.040.30
Word Count Estimation: 7,771
Date of Issue: 2008-03-12
Date of Implementation: 2008-09-01
Older Standard (superseded by this standard): YS/T 244.5-1994
Regulation (derived from): NDRC Notice No. 25 of 2008
Issuing agency(ies): National Development and Reform Commission
Summary: This standard provides high purity copper, zinc and lead content determination method. This standard applies to high purity copper, zinc and lead content. Measuring range: Copper: 0. 00005% 0. 00050%, Zinc: 0. 00002% 0. 00050%, Lead: ~ 0. 000060% 0. 000003%.

YS/T 244.5-2008: Chemical analysis methods of high purity aluminium. Part 5: Determination of copper, zinc and lead content by anodic spripping voltammetric method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis methods of high purity aluminium.Part 5. Determination of copper, zinc and lead content by anodic spripping voltammetric method ICS 77.040.30 H12 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 244.5-1994 Chemical analysis methods of high purity aluminum Part 5. anodic stripping voltammetry Determination of copper, zinc and lead content Posted 2008-03-12 2008-09-01 implementation National Development and Reform Commission issued

Foreword

YS/T 244 "Chemical analysis methods of high purity aluminum" is divided into nine sections. --- Part 1. phenanthroline - thiocyanate spectrophotometric determination of iron content; --- Part 2. molybdenum blue extraction and spectrophotometric determination of silicon content; --- Part 3. Two-antipyrine DAM - spectrophotometric determination of titanium content thiocyanate; --- Part 4. Butyl Rhodamine B spectrophotometric determination of gallium content; --- Part 5. Determination of copper, zinc and lead content anodic stripping voltammetry; --- Part 6. Catalytic manganese - sulfuric acid system through the determination of silver content; --- Part 7. dithizone extraction and spectrophotometric determination of cadmium content; --- Part 8. crystal violet extraction and spectrophotometric determination of indium content; --- Part 9. Determination of impurities by inductively coupled plasma mass spectrometry. This is Part 5. The partial replacement of YS/T 244.5-1994 "Chemical analysis methods of high purity aluminum anodes - Determination of copper, zinc and lead content stripping voltammetry." This part is YS/T 244.5-1994 revision. Compared with YS/T 244.5-1994, the main changes are as follows. --- Added "repeatability" clause; --- Increase the "quality assurance and control" clause. The non-ferrous metal part by the National Standardization Technical Committee and centralized. This part of the Fushun Aluminum Co., Ltd., China Nonferrous Metals Industry Institute of Standards Metrology and Quality is responsible for drafting. This part of the Fushun Aluminum Co. drafted. The main drafters of this section. Yang Yuhong, original Jianchang, Yang Limei. This part of the standard replaces the previous editions are. --- YS/T 244.5-1994. Chemical analysis methods of high purity aluminum Part 5. anodic stripping voltammetry Determination of copper, zinc and lead content

1 Scope

This section provides high purity determination of copper, zinc and lead content. This section applies to the determination of high purity copper, zinc and lead content. Measurement range. Copper. 0.00005% - 0.00050%; zinc. 0.00002% - 0.00050%; Lead. ~ 0.000003% 0.000060%.

2 Method summary

Sample was dissolved in nitric acid and hydrochloric acid, heating evaporation, acidity about pH = 3, the measured voltammetry using platinum ball silver Mercury Film Electrode Anodic Stripping Fixed copper and zinc; determination of lead glass carbon electrode by anodic stripping voltammetry. High purity aluminum impurities present not interfere with the determination.

3 Reagents

Reagent preparation and analysis of water are deionized water and then purified by distillation quartz distiller. 3.1 ethanol, pure class distinctions. 3.2 argon (99.99%). Nitrate 3.3 (ρ1.42g/mL), of high purity. 3.4 nitric acid (1 + 1), of high purity. 3.5 hydrochloric acid (1 + 1), high purity or purified by gas balance. Hydrochloride 3.6 (1 + 3), of high purity. 3.7 mercuric chloride stock solution. Weigh 0.5000g mercuric chloride, placed in 200mL beaker, add 50mL water, 1mL hydrochloric acid (3.5) stir Mix until completely dissolved. Transferred to 100mL volumetric flask, dilute with water to volume, and mix. 1mL solution containing 5mg of mercury chloride. 3.8 mercuric chloride solution. Pipette 10.80mL mercuric chloride stock solution (3.7) in 100mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 0.54mg of mercury chloride. 3.9 copper standard stock solution. Weigh 0.5000g copper (99.99%), placed in 200mL beaker, add 20mL of nitric acid (3.4), dissolved by heating on a hot plate, and evaporated to near a paste. Added 10mL of hydrochloric acid (3.5) and heated to a volume of about 2mL, remove the cold However, wash the cup wall and transferred to 500mL volumetric flask, dilute with water to volume, and mix. 1mL solution containing 1mg of copper. 3.10 Copper standard solution. Pipette 25.0mL copper standard stock solution (3.9) in 250mL volumetric flask, dilute with water to volume, and mix. again From this solution Pipette 20.0mL, placed in 200mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 10μg copper. 3.11 standard zinc stock solution. Weigh 0.5000g zinc (99.99%), placed in 200mL beaker, add 10mL hydrochloric acid (3.5), on a hot plate heated to dissolve completely, remove cooling, wash the cup wall and transferred to 500mL volumetric flask, dilute to the mark with water, mix uniform. 1mL solution containing 1mg zinc. 3.12 Zinc standard solution. Pipette 25.0mL zinc standard solution (3.11) in 250mL volumetric flask, dilute with water to volume, and mix. again From this solution Pipette 10.0mL in 200mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 5μg zinc. 3.13 lead standard stock solution. Weigh 0.5000g metallic lead (99.99%), placed in 200mL beaker, add 20mL of nitric acid (3.4), dissolved by heating on a hot plate, and evaporated to near a paste. Added 10mL of hydrochloric acid (3.5), heated to distill to a volume of about 2mL, remove the cold However, wash the cup wall and transferred to 500mL volumetric flask, dilute with water to volume, and mix. 1mL solution containing 1mg lead. 3.14 Lead standard solution. Pipette 25.0mL lead standard stock solution (3.13) in 250mL volumetric flask, dilute with water to volume, and mix. Then from this solution Pipette 10.0mL in 200mL volumetric flask, dilute with water to volume, and mix. This solution 1mL containing 5μg lead.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 244.5-2008_English be delivered?

Answer: Upon your order, we will start to translate YS/T 244.5-2008_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 244.5-2008_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 244.5-2008_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.