Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YS/T 229.4-2013 English PDF

US$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YS/T 229.4-2013: Chemical analysis methods for high purity lead. Part 4: Determination of trace impurity elements content. Glow discharge mass spectrometry
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YS/T 229.4-2013189 Add to Cart 3 days Chemical analysis methods for high purity lead. Part 4: Determination of trace impurity elements content. Glow discharge mass spectrometry Valid

Similar standards

GB/T 3884.2   GB/T 3884.1   YS/T 252.1   YS/T 229.2   YS/T 229.3   YS/T 229.1   

Basic data

Standard ID: YS/T 229.4-2013 (YS/T229.4-2013)
Description (Translated English): Chemical analysis methods for high purity lead. Part 4: Determination of trace impurity elements content. Glow discharge mass spectrometry
Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended)
Classification of Chinese Standard: H13
Classification of International Standard: 77.120.60
Word Count Estimation: 7,724
Regulation (derived from): Ministry of Industry and Information Technology Bulletin No. 52, 2013; industry standard for filing Notice No. 1 of 2014 (No. 169 overall)
Issuing agency(ies): Ministry of Industry and Information Technology
Summary: This standard specifies the method for the determination of trace elements in high purity lead content. This standard applies to the determination of trace elements in high purity lead content. Determination of the elements as follows: sulfur, selenium me

YS/T 229.4-2013: Chemical analysis methods for high purity lead. Part 4: Determination of trace impurity elements content. Glow discharge mass spectrometry


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis methods for high purity lead Part 4. Determination of trace impurity elements content Glow discharge mass spectrometry ICS 77.120.60 H13 People's Republic of China Nonferrous Metals Industry Standard Methods for chemical analysis of high purity lead Part 4. Determination of trace element contents Glow Discharge Mass Spectrometry Part 4. Determinationoftraceimpurityelementscontent- Issued on. 2013-10-17 2014-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released

Foreword

YS/T 229-2013 "high purity chemical analysis of lead" is divided into four parts. --- Part 1. silver, copper, bismuth, aluminum, nickel, tin, magnesium, and iron - Determination of chemical spectroscopy; --- Part 2. Determination of arsenic content by atomic fluorescence spectrometry; --- Part 3. Determination of antimony content - Atomic Fluorescence Spectrometry; --- Part 4. Determination of trace element contents of glow discharge mass spectrometry. This is Part 4 YS/T 229's. This section drafted in accordance with GB/T 1.1-2009 given rules. This standard by the national non-ferrous metals Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Dongfang Electric Group Emei Semiconductor Materials Research Institute. Participated in the drafting of this section. Beijing Nonferrous Metal Research Institute, New Material Technology Co., Ltd. Jinchuan. The main drafters of this section. Wang Panfeng, Wenying, Sun Ping, Liu, Qiu Ping, Xu Shunbo. Methods for chemical analysis of high purity lead Part 4. Determination of trace element contents Glow Discharge Mass Spectrometry

1 Scope

This section YS/T 229 specifies the method for determination of trace elements in high purity lead content, the determination of elements in Table 1. This section applies to the determination of trace elements in high purity lead content. Determination of the elements as follows. measurement range of sulfur and selenium for 100μg/kg ~ 5000μg/kg, the remaining elements of the measurement range of 1μg/kg ~ 5000μg/kg.

2 principle of the method

Sample as a cathode glow discharge, the surface atoms to be sputtered from the sample and enters the glow discharge plasma, the plasma Ionized and then introduced into the mass spectrometer. In each element isotope mass number punishable by default scan points and the integration time of the peak corresponding plot Min, the resulting area is the peak intensity. When semi-quantitative analysis, computer software instrument based on "typical relative sensitivity factor" Auto Calculate the mass content of each element; when quantitative analysis is required by the sample in the same assay conditions, the structure of the ion source and measure Under standard test conditions for independent samples was determined by the relative sensitivity factors, the application of the relative sensitivity factor to calculate the mass of each element content.

3 Reagents and materials

Unless otherwise indicated, the reagents used in the tests were excellent pure; the water used is deionized water, the resistivity required to achieve 18.2MΩ/cm. 3.1 Nitrogen (φ≥99.99%). 3.2 nitric acid (11). 3.3 lead standard samples, the measured element mass content of between 50μg/kg ~ 500μg/kg. 3.4 lead blank sample, the element content is less than the requirements of the test sample under test element content more than 10 times.

4 Instrument

4.1 high resolution glow discharge mass spectrometer, under the resolution mode resolution of up to 3000 to 4000, high-resolution mode resolution Rate of up to 9,000 to 10,000. 4.2 machining equipment, the sample can be prepared as desired geometry (block or rod), the sample to be analyzed surface should be flat and smooth. 4.3 Determination of Isotopic and resolution shown in Table 1, the requirements of 208Pb isotope peak intensity spectrum measured is not less than 5 × 109cps, peak pictogram Together resolution requirements.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YS/T 229.4-2013_English be delivered?

Answer: Upon your order, we will start to translate YS/T 229.4-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YS/T 229.4-2013_English with my colleagues?

Answer: Yes. The purchased PDF of YS/T 229.4-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.