YS/T 227.4-2010 English PDFUS$209.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 227.4-2010: Methods for chemical analysis of tellurium. Part 4: Determination of iron content. Phenanthroline spectrophotometry YS/T 227.4: Historical versions
Basic dataStandard ID: YS/T 227.4-2010 (YS/T227.4-2010)Description (Translated English): Methods for chemical analysis of tellurium. Part 4: Determination of iron content. Phenanthroline spectrophotometry Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.120.99 Word Count Estimation: 6,651 Date of Issue: 2010-11-22 Date of Implementation: 2011-03-01 Older Standard (superseded by this standard): YS/T 227.4-1994 Regulation (derived from): MIIT (2010) No. 126 Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the tellurium Determination of iron content. This standard applies to the determination of tellurium in iron content. Measuring range: 0. 0005% to 0. 006% YS/T 227.4-2010: Methods for chemical analysis of tellurium. Part 4: Determination of iron content. Phenanthroline spectrophotometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of tellurium.Part 4. Determination of iron content.Phenanthroline spectrophotometry ICS 77.120.99 H13 People's Republic of China Nonferrous Metals Industry Standard Replacing YS/T 227.4-1994 Methods for chemical analysis of tellurium Part 4. Determination of iron content Phenanthroline spectrophotometry Part 4. Determinationofironcontent- Issued on. 2010-11-22 2011-03-01 implementation Ministry of Industry and Information Technology of the People's Republic of China released ForewordYS/T 227 "tellurium chemical analysis methods," a total of 12 parts. --- Part 1. Determination of bismuth content hydride generation - atomic fluorescence spectrometry; --- Part 2. Determination of aluminum content Chromazurol S- bromo cylpyridinium micellar solubilization spectrophotometry; --- Part 3. Determination of lead content by flame atomic absorption spectrometry; --- Part 4. Determination of iron content - Phenanthroline spectrophotometric method; --- Part 5. determination of selenium content of 2,3-diaminonaphthalene spectrophotometry; --- Part 6. Determination of copper content of solid-liquid separation - flame atomic absorption spectrometry; --- Part 7. Determination of sulfur content by inductively coupled plasma atomic emission spectrometry; --- Part 8. magnesium, sodium content - Flame atomic absorption spectrometry; --- Part 9. Determination of tellurium content of potassium dichromate - ammonium ferrous sulfate volumetric method; --- Part 10. Determination of arsenic content by hydride generation - atomic fluorescence spectrometry; --- Part 11. Determination of silicon content of n-butanol silicon molybdenum blue spectrophotometric method; --- Part 12. bismuth, aluminum, lead, iron, selenium, copper, magnesium, sodium, arsenic content - Inductively coupled plasma atomic emission spectrometry. This is Part 4. This section drafted in accordance with GB/T 1.1-2009 given rules. The partial replacement of YS/T 227.4-1994 "Tellurium Determination of iron content (phenanthroline photometric method)." And YS/T 227.4-1994 Compared to the main part of the following changes. --- Complements the precision, quality assurance and control provisions; --- Complements the "test report" requirement. The non-ferrous metal part by the National Standardization Technical Committee (SAC/TC243) centralized. This section is responsible for drafting unit. Zhuzhou Smelter Group Co., Ltd. This section is drafted. Sichuan Apollo Solar Energy Technology Co., Ltd. It participated in the drafting of this section. MCC Huludao Nonferrous Metals Group Co., Ltd., Henan Yuguang Gold & Lead Co., Ltd. The main drafters of this section. Liu Li, Yan Ge, Liu Limin, Li Dongmei, Zhou Junling. This part of the standard replaces the previous editions are. --- YS/T 227.4-1994; --- GB/T 2140-1980. Methods for chemical analysis of tellurium Part 4. Determination of iron content Phenanthroline spectrophotometry Warning. Use of this standard shall have a person experiences regular laboratory work. This standard does not point out all possible security issues. Users have the responsibility to take appropriate safety and health practices and to ensure compliance with the conditions relevant national regulations.1 ScopeThis section YS/T 227 specifies the method for determination of tellurium in iron content. This section applies to the determination of iron content in tellurium. Measurement range. 0.0005% to 0.006%.2 principle of the methodSamples with hydrochloric acid, nitric acid dissolved in hydrochloric acid medium, sulfite reduction tellurite to tellurium acid precipitation to remove the matrix, iron and phenanthroline formed Colored complex in a spectrophotometer at a wavelength of 510nm absorbance measurement of iron. Calculate the amount of iron by standard curve method.3 ReagentsUnless otherwise indicated in the analysis using only recognized as an analytical reagent and water. Are used in the test vessel with dilute aqua regia (11) After soaking, wash thoroughly with a water. Nitrate 3.1 (ρ1.42g/mL), ultra-pure. 3.2 hydrochloride (ρ1.19g/mL), ultra-pure. 3.3 Ammonia (ρ0.90g/mL), ultra-pure. 3.4 sulfurous acid (sulfur dioxide containing not less than 6.0%). 3.5 hydrochloride (11). 3.6 Disodium ethylenediaminetetraacetate solution (100g/L). 3.7 tartaric acid solution (200g/L). 3.8 hydroxylamine hydrochloride solution (100g/L). 3.9 phenanthroline solution (5g/L). Weigh 0.50g phen, was dissolved in 20mL of ethanol, diluted with water to 100mL. 3.10 iron standard stock solution. Weigh 0.1000g iron (≥99.95%), placed in 100mL beaker, add 10mL of hydrochloric acid (3.2), 1mL of nitric acid (3.1), the solution was heated to boil, get rid of nitrogen oxides, is removed, cooled to room temperature, transferred to 1000mL volumetric flask, washed with water Dilute to the mark. This solution 1mL containing 100μg iron. 3.11 Iron standard solution. Pipette 10.00mL iron standard stock solution (3.10), placed in 200mL volumetric flask, dilute to the mark, Shake well. This solution 1mL containing 5μg iron.4 InstrumentSpectrophotometer. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 227.4-2010_English be delivered?Answer: Upon your order, we will start to translate YS/T 227.4-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 227.4-2010_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 227.4-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YS/T 227.4-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YS/T 227.4-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |