YS/T 1057-2015 English PDFUS$189.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YS/T 1057-2015: Methods for chemical analysis of cobaltosic oxide. Determination of magnetic Impurities content. Magnetic separation. Inductively coupled plasma atomic emission spectrometry Status: Valid
Basic dataStandard ID: YS/T 1057-2015 (YS/T1057-2015)Description (Translated English): Methods for chemical analysis of cobaltosic oxide. Determination of magnetic Impurities content. Magnetic separation. Inductively coupled plasma atomic emission spectrometry Sector / Industry: Nonferrous Metallurgy Industry Standard (Recommended) Classification of Chinese Standard: H13 Classification of International Standard: 77.120.70 Word Count Estimation: 8,834 Date of Issue: 2015-04-30 Date of Implementation: 2015-10-01 Quoted Standard: GB/T 1467; GB/T 6682; JY/T 015 Regulation (derived from): Ministry of Industry and Information Technology Announcement (2015 No. 28) Issuing agency(ies): Ministry of Industry and Information Technology Summary: This standard specifies the method for the determination of iron, nickel, zinc and chromium contents of magnetic foreign matter in cobalt tetroxide. This standard is applicable to the determination of iron, nickel, zinc and chromium in magnetite, which is in the range of 0.01g/t ~ 5.0g/t. YS/T 1057-2015: Methods for chemical analysis of cobaltosic oxide. Determination of magnetic Impurities content. Magnetic separation. Inductively coupled plasma atomic emission spectrometry---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Methods for chemical analysis of cobaltosic oxide. Determination of magnetic Impurities content. Magnetic separation. Inductively coupled plasma atomic emission spectrometry ICS 77.120.70 H13 People's Republic of China non-ferrous metal industry standards Cobalt tetroxide - Chemical analysis methods Magnetic foreign body content determination Magnetic Separation - Inductively Coupled Plasma Atomic Emission Spectrometry Methods for chemical analysis of cobaltalt oxide- 2015-04-30 release 2015-10-01 implementation Ministry of Industry and Information Technology of the People's Republic of China ForewordThis standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard is proposed and managed by the National Nonferrous Metal Standardization Technical Committee (SAC/TC243). This standard is drafted by. Jinchuan Group Co., Ltd., Zhejiang Huayou Cobalt Co., Ltd. This standard participates in the drafting unit. Yingde Jia satisfied Metal Technology Co., Ltd., Shenzhen Greenmei High-tech Co., Ltd., Tianjin Mao Alliance Technology Co., Ltd. The main drafters of this standard. Qiu Ping, Wang Xiaofen, Qi Shiqing, Zhang Meifen, Wu Chi Chun, Julie, Wu Yingchun, Zhao Furong, Xie Bohua, Luo Yueying, Tian Yu universe, Huang Xiuhua, had Xuelian. Cobalt tetroxide - Chemical analysis methods Magnetic foreign body content determination Magnetic Separation - Inductively Coupled Plasma Atomic Emission Spectrometry1 ScopeThis standard specifies the determination of cobalt oxide in magnetic foreign matter iron, nickel, zinc, chromium content. This standard is applicable to the determination of iron, nickel, zinc and chromium in the magnetic foreign body of cobalt tetroxide in the range of 0.01g/t ~ 5.0g/t.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB/T 1467 Metallurgical products - General principles for chemical analysis methods and general provisions GB/T 6682 analytical laboratory water specifications and test methods General principles of JY/T 015 inductively coupled plasma atomic emission spectrometry3 method summaryThe sample is slurried in water, and magnetic iron, nickel, zinc and chromium in the sample are enriched with magnetic particles, the enriched magnetic substance is dissolved in aqua regia, and then the electricity Determination of Iron, Nickel, Zinc and Chromium by Inductively Coupled Plasma Atomic Emission Spectrometry.4 reagentUnless otherwise indicated, the reagents used in this standard are of analytical grade, the water used are two water, the specific requirements should be consistent with GB/T 1467, GB/T 6682's provisions. 4.1 Nitric acid (p = 1.42 g/mL). 4.2 Hydrochloric acid (p = 1.19 g/mL). 4.3 iron standard storage solution Weigh 1.0000g metal iron [w (Fe) ≥ 99.99%] in a beaker, slowly added 40mL (11) nitrate Acid, cover the table, dissolved at low temperature, drive out nitrogen oxides, remove, cool, wash the table with water and glass wall, into the 1000mL volumetric flask, And dilute to the mark, shake well. 1 mL of this solution contains 1 mg of iron. 4.4 Nickel standard stock solution Weigh 1.0000g of metallic nickel [w (Ni) ≥99.99%] In a beaker, add (11) nitric acid to dissolve with 5% nitric acid (volume fraction) into 1000mL volumetric flask, and diluted to the mark, shake. 1 mL of this solution contains 1 mg of nickel. 4.5 Standard zinc storage solution Weigh 1.2446g of high purity zinc oxide (ZnO) calcined at 1000 ℃ to constant weight in a beaker, add 100mL Water and 20mL hydrochloric acid (4.2) dissolved, with 5% hydrochloric acid (volume fraction) into 1000mL volumetric flask, and diluted to the mark, shake. this 1mL solution containing 1mg zinc. 4.6 chromium standard stock solution Weigh 1.0000g of metallic chromium [w (Cr) ≥ 99.99%] in a beaker, add 5mL hydrochloric acid (4.2) dissolved with 5% hydrochloric acid (volume fraction) into 1000mL volumetric flask, and diluted to the mark, shake. 1 mL of this solution contains 1 mg chromium. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YS/T 1057-2015_English be delivered?Answer: Upon your order, we will start to translate YS/T 1057-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YS/T 1057-2015_English with my colleagues?Answer: Yes. The purchased PDF of YS/T 1057-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |