Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

YBB 0008-2005 English PDF

US$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
YBB 0008-2005: Caps made of aluminium for Injection
Status: Obsolete

YBB 0008: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
YBB 0008-2005279 Add to Cart 3 days Caps made of aluminium for Injection Obsolete
YBB 0008-2004239 Add to Cart 2 days Bromobutyl rubber plungers for prefilled syringes Obsolete
YBB 0008-200390 Add to Cart Auto, < 3 mins Tests for Gas Transmission Obsolete
YBB 0008-2002199 Add to Cart 2 days PP Bottles Oral Liquid Preparation Obsolete

Similar standards

YBB 6006   YBB 2027   YBB 00012003   YBB 00012002   YBB000   

Basic data

Standard ID: YBB 0008-2005 (YBB0008-2005)
Description (Translated English): Zhushejipingyong Lugai Caps made of aluminium for Injection
Sector / Industry: Medical & Pharmaceutical Packaging Industry Standard
Classification of Chinese Standard: C08
Classification of International Standard: 11.020
Word Count Estimation: 7,731
Date of Issue: 2/21/2006
Date of Implementation: 2006-06-01
Regulation (derived from): State Administration of Food and Drug Administration Announcement No. 164 of 2015
Summary: This standard applies to injection bottles with aluminum cover.
YBB00082003 (YBB 0008-2003) YBB National Drugs Packing Containers (Materials) Standards YBB00082003 Tests for Gas Transmission (on trial) China Food and Drug Administration China Food and Drug Administration National Drugs Packing Containers (Materials) Standards YBB00082003 Tests for Gas Transmission (on trial) Gas transmission quantity is, under constant temperature and unit pressure, the gas volume that transmits stably through per unit area of the sample in per unit time. It is expressed as the value of volume under standard temperature and pressure with the unit. cm3/ (m2·24h·0.1Mpa). Gas transmission coefficient is, under constant temperature and unit pressure difference, the gas volume that transmits stably through per unit thickness and unit area of the sample in per unit time. It is expressed as the value of volume under standard temperature and pressure with the unit. cm3·cm/ (m2·S·Pa). Testing environment. temperature. (23±2)°C, relative humidity. (50±5) %. First method. Pressure-difference method Use medicinal membrane or sheet to separate low pressure chamber from high pressure chamber. The volume of low pressure chamber is known; then inflate about 0.1Mpa test gas into high pressure chamber. After sealing, use the vacuum pump to evacuate the gas in low pressure chamber until approaching zero value. Use manometer to measure the rise of pressure in low pressure chamber. Thus, the gas volume transmits through sample from high pressure chamber to low pressure chamber based on time function will be determined. However, the initial phase of transmission velocity that changes over time shall be excluded. Apparatus The meters and equipment for testing gas transmission quantity are as bellows. Vent chamber. it is consisted of two parts. When sample is installed, the upper part is high pressure chamber used for storing test gas, and the lower part is low pressure chamber used for storing the transmitted gas and measuring the pressure difference during transmission. Both parts are equipped with injection pipes for test gas. valve of high-pressure chamber; start to evacuate the vacuum until the pressure is lower than 27Kpa; then keep degassing. After degassing, open test gas cylinder; turn on gas-source valve; inflate the test gas into high-pressure chamber. The gas flow per minute is 100ml. Gas pressure of high-pressure chamber shall be kept within (1.0~1.1) ×105Pa. Close the vent valves of high- pressure and low-pressure chambers; start the transmission test. In order to exclude the nonlinearity phase in the beginning, 10 minutes pre-transmission is required. When the changes of pressure difference over certain time intervals are gradually constant, stable transmission is accomplished. Gas transmission quantity (Qg) shall be calculated according to formula (1). Formula (1). Where. Qg — Gas transmission quantity, cm3/ (m2·24h·0.1Mpa); ΔP/Δt — Arithmetic mean value of pressure changes of low pressure chamber in unit time during stable transmission, Pa/h; V — Volume of low pressure chamber, cm3; S — Test area of sample, m2; T — Test temperature, K; P1-P2 — Pressure difference on sample’s both sides, Pa; T0, P0 — Temperature (273.15K) and pressure (1.0133×105Pa) under standard state. Test result is expressed as the arithmetic mean value of three samples. The difference between determined value of each sample and arithmetic mean value shall not be greater than ±10%. Gas transmission coefficient (Pg) shall be calculated according to formula (2). Formula (2). ......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of YBB 0008-2005_English be delivered?

Answer: Upon your order, we will start to translate YBB 0008-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of YBB 0008-2005_English with my colleagues?

Answer: Yes. The purchased PDF of YBB 0008-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version YBB 0008-2005?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YBB 0008-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.