YBB 0008-2005 English PDFUS$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. YBB 0008-2005: Caps made of aluminium for Injection Status: Obsolete YBB 0008: Historical versions
Basic dataStandard ID: YBB 0008-2005 (YBB0008-2005)Description (Translated English): Zhushejipingyong Lugai Caps made of aluminium for Injection Sector / Industry: Medical & Pharmaceutical Packaging Industry Standard Classification of Chinese Standard: C08 Classification of International Standard: 11.020 Word Count Estimation: 7,731 Date of Issue: 2/21/2006 Date of Implementation: 2006-06-01 Regulation (derived from): State Administration of Food and Drug Administration Announcement No. 164 of 2015 Summary: This standard applies to injection bottles with aluminum cover. YBB00082003 (YBB 0008-2003)
YBB
National Drugs Packing Containers (Materials) Standards
YBB00082003
Tests for Gas Transmission (on trial)
China Food and Drug Administration
China Food and Drug Administration
National Drugs Packing Containers (Materials) Standards
YBB00082003
Tests for Gas Transmission (on trial)
Gas transmission quantity is, under constant temperature and unit pressure,
the gas volume that transmits stably through per unit area of the sample in per
unit time. It is expressed as the value of volume under standard temperature
and pressure with the unit. cm3/ (m2·24h·0.1Mpa).
Gas transmission coefficient is, under constant temperature and unit pressure
difference, the gas volume that transmits stably through per unit thickness and
unit area of the sample in per unit time. It is expressed as the value of volume
under standard temperature and pressure with the unit. cm3·cm/ (m2·S·Pa).
Testing environment. temperature. (23±2)°C, relative humidity. (50±5) %.
First method. Pressure-difference method
Use medicinal membrane or sheet to separate low pressure chamber from high
pressure chamber. The volume of low pressure chamber is known; then inflate
about 0.1Mpa test gas into high pressure chamber. After sealing, use the
vacuum pump to evacuate the gas in low pressure chamber until approaching
zero value. Use manometer to measure the rise of pressure in low pressure
chamber. Thus, the gas volume transmits through sample from high pressure
chamber to low pressure chamber based on time function will be determined.
However, the initial phase of transmission velocity that changes over time shall
be excluded.
Apparatus
The meters and equipment for testing gas transmission quantity are as bellows.
Vent chamber. it is consisted of two parts. When sample is installed, the upper
part is high pressure chamber used for storing test gas, and the lower part is
low pressure chamber used for storing the transmitted gas and measuring the
pressure difference during transmission. Both parts are equipped with injection
pipes for test gas.
valve of high-pressure chamber; start to evacuate the vacuum until the pressure
is lower than 27Kpa; then keep degassing. After degassing, open test gas
cylinder; turn on gas-source valve; inflate the test gas into high-pressure
chamber. The gas flow per minute is 100ml. Gas pressure of high-pressure
chamber shall be kept within (1.0~1.1) ×105Pa. Close the vent valves of high-
pressure and low-pressure chambers; start the transmission test. In order to
exclude the nonlinearity phase in the beginning, 10 minutes pre-transmission is
required. When the changes of pressure difference over certain time intervals
are gradually constant, stable transmission is accomplished. Gas transmission
quantity (Qg) shall be calculated according to formula (1).
Formula (1).
Where.
Qg — Gas transmission quantity, cm3/ (m2·24h·0.1Mpa);
ΔP/Δt — Arithmetic mean value of pressure changes of low pressure
chamber in unit time during stable transmission, Pa/h;
V — Volume of low pressure chamber, cm3;
S — Test area of sample, m2;
T — Test temperature, K;
P1-P2 — Pressure difference on sample’s both sides, Pa;
T0, P0 — Temperature (273.15K) and pressure (1.0133×105Pa) under
standard state.
Test result is expressed as the arithmetic mean value of three samples. The
difference between determined value of each sample and arithmetic mean
value shall not be greater than ±10%.
Gas transmission coefficient (Pg) shall be calculated according to formula (2).
Formula (2).
......
Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of YBB 0008-2005_English be delivered?Answer: Upon your order, we will start to translate YBB 0008-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of YBB 0008-2005_English with my colleagues?Answer: Yes. The purchased PDF of YBB 0008-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version YBB 0008-2005?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version YBB 0008-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |