WS 506-2016 English PDFUS$419.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. WS 506-2016: Regulation for disinfection and sterilization technique of dental instruments Status: Valid
Basic dataStandard ID: WS 506-2016 (WS506-2016)Description (Translated English): Regulation for disinfection and sterilization technique of dental instruments Sector / Industry: Health Industry Standard Classification of Chinese Standard: C05 Word Count Estimation: 18,140 Date of Issue: 2016-12-27 Date of Implementation: 2017-06-01 Quoted Standard: GB 15982; GB/T 19633; WS 310.2; WS 310.3; WS/T 367; YY 0646 Regulation (derived from): State-Health-Communication (2016) No.23 Issuing agency(ies): National Health and Family Planning Commission of the People's Republic of China Summary: This standard specifies the management requirements, basic principles, operational procedures, sterilization monitoring, sterilization and release requirements of sterilization products for oral instruments. This standard applies to all levels of various types of oral disease prevention, diagnosis, treatment services, medical institutions. Has been achieved disinfection supply center centralized supply, the disposal of oral instruments can refer to the implementation of this standard. WS 506-2016: Regulation for disinfection and sterilization technique of dental instruments---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Regulation for disinfection and sterilization technique of dental instruments ICS 11.020 C05 People's Republic of China health industry standards Dental sterilization equipment sterilization techniques and specifications 2016-12-27 release 2017-06-01 Implementation People's Republic of China National Health and Family Planning Commission released Directory Preface Ⅰ 1 Scope 1 2 Normative references 1 3 Terms and definitions 1 4 Management Requirements 2 5 basic principles of oral appliance treatment 3 6 oral device processing operation flow 3 7 monitoring requirements 5 8 disinfection and sterilization items release 5 9 equipment storage 5 Appendix A (Normative) Training content and management requirements 6 Appendix B (Normative) Classification and disinfection of oral appliances, sterilization, storage requirements 7 Appendix C (Normative) instruments, appliances and articles cleaning method of operation 8 Appendix D (normative) dental handpiece cleaning and maintenance methods 10 Appendix E (Normative) Small sterilizer sterilization and monitoring requirements 13 Appendix F (Informative) Sterilizer sterilization cycle operation record table 15 ForewordThis standard 4.2.2d), 4.3.3,4.4.3,6.1.2a) and c), 6.2.2,6.2.3,6.2.4,6.3,6.6.2,6.6.3,6.7.2, 7.1.3 is recommended Sexual terms, the rest is mandatory terms. This standard is formulated in accordance with Law of the People's Republic of China on Prevention and Treatment of Infectious Diseases and Measures for the Management of Nosocomial Infections. This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard was drafted. Stomatological Hospital of Peking University, Beijing Stomatological Hospital Affiliated to Capital Medical University, Tianjin Nankai University Stomatology Hospital, Stomatological Hospital of Jilin University, Affiliated Stomatological Hospital of Sun Yat-sen University, China Center for Disease Control and Prevention, Peking University First Hospital. The main drafters of this standard. Shen Shuming, Liu Cuimei, Yu Guangyan, Su Jing, Ding Xiaofang, Liu Dongling, Zhang small slow, Bahai group, Li six hundred million, Wang Chunli, Li Xiu E. Dental sterilization equipment sterilization techniques and specifications1 ScopeThis standard specifies the disinfection and sterilization of oral equipment management requirements, basic principles, procedures, sterilization monitoring, release of sterile items and equipment Storage requirements. This standard applies to all levels of various types of oral disease prevention, diagnosis and treatment services to medical institutions. Has achieved disinfection supply center Supplied, the disposal of oral instruments can refer to the implementation of this standard.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version applies to this article Pieces. For undated references, the latest edition (including all amendments) applies to this document. GB 15982 hospital disinfection health standards GB/T 19633 Packaging of final sterilized medical devices WS 310.2 Hospital Disinfection Supply Center - Part 2. Code of Practice for Cleaning, Disinfection and Sterilization WS 310.3 Hospital Disinfection Supply Center Part 3. Cleaning and disinfection and sterilization effect monitoring standards WS/T 367 medical institutions disinfection specifications YY0646 small steam sterilizer automatic control type3 Terms and definitionsThe following terms and definitions apply to this document. 3.1 Dental instruments dentaldevices Reusable instruments, appliances and articles for the prevention, diagnosis, treatment of oral disorders and oral health. 3.2 Dental small instruments smaldentaldevices Smaller specifications of dental equipment, such as various types of car needles, root canal equipment. 3.3 Dental handpiece Handheld tool holder for delivering energy (with or without conversion) to a dental tool or appliance. 3.4 Root canal device root-canalinstruments Instruments used to probe, penetrate, prepare or fill the root canal, such as root canal files, root canal expanders, and root canal stitches. 3.5 Teeth scaler Specially designed and/or hand or powered dental instruments for removing tartar on tooth surfaces. 3.6 Highly dangerous dental instruments criticaldentalinstruments Penetrating soft tissue, touching the bone, access to or in contact with blood or other sterile tissue. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of WS 506-2016_English be delivered?Answer: Upon your order, we will start to translate WS 506-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of WS 506-2016_English with my colleagues?Answer: Yes. The purchased PDF of WS 506-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |