Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
SN/T 4501.1-2016169 Add to Cart 3 days Chemical analysis of nickel concentrate--Part 1: Determination of nickel, cobalt, copper, manganese, magnesium, calcium content--Inductively coupled plasma atomic emission spectrometry Valid

Similar standards

GB/T 3884.1   GB/T 3884.2   GB/T 4103.14   SN/T 5625   SN/T 4501.3   SN/T 4501.2   

Basic data

Standard ID: SN/T 4501.1-2016 (SN/T4501.1-2016)
Description (Translated English): Chemical analysis of nickel concentrate--Part 1: Determination of nickel, cobalt, copper, manganese, magnesium, calcium content--Inductively coupled plasma atomic emission spectrometry
Sector / Industry: Commodity Inspection Standard (Recommended)
Classification of Chinese Standard: H13
Word Count Estimation: 7,769
Date of Issue: 2016-06-28
Date of Implementation: 2017-02-01
Regulation (derived from): State-Quality-Inspection-Accredidation [2016] No.318
Issuing agency(ies): General Administration of Customs

SN/T 4501.1-2016: Chemical analysis of nickel concentrate--Part 1: Determination of nickel, cobalt, copper, manganese, magnesium, calcium content--Inductively coupled plasma atomic emission spectrometry



---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Chemical analysis of nickel concentrate - Part 1. Determination of nickel, cobalt, copper, manganese, magnesium, calcium content - Inductively coupled plasma production emission spectrometry People's Republic of China Entry - Exit Inspection and Quarantine Industry Standard Methods for chemical analysis of nickel concentrates - Part 1. Nickel, cobalt, Copper, Manganese, Magnesium, Calcium Content Determination Inductively Coupled Plasma atomic emission spectrometry Chemicalanalysisofnickelconcentrate-Part 1. Determination of nickel, cobalt, copper, manganese, magnesium, calciumcontent- 2016-06-28 released 2017-02-01 implementation People's Republic of China State Administration of Quality Supervision, Inspection and Quarantine issued

Foreword

SN/T 4501 is divided into several parts. This part is part 1 of SN/T 4501. This part is drafted in accordance with the rules given in GB/T 1.1-2009. This part of the State Certification and Accreditation Administration Committee proposed and centralized. This part of the main drafting unit. the People's Republic of China Jiangsu Entry - Exit Inspection and Quarantine Bureau. This part of the main drafters. Qin Lijun, Jiang Yu, Zheng Guangyu, Wang Heng, Bian Guanghong, Qiao Zhu, Feng Yahui, Shi Hui, Liu Yajun, Zheng Jianming, Zhu Shengpei, Xia Xinyuan, Zhang Mei, Xue Feng. Methods for chemical analysis of nickel concentrates - Part 1. Nickel, cobalt, Copper, Manganese, Magnesium, Calcium Content Determination Inductively Coupled Plasma atomic emission spectrometry WARNING - Personnel using this standard should have practical experience in formal laboratory work. This standard does not indicate all possible safety issues, It is the user's responsibility to take appropriate safety and health measures and to ensure compliance with the conditions set forth in the relevant national laws and regulations.

1 Scope

This part of SN/T 4501 specifies the determination of nickel, cobalt, copper, manganese, and nickel in nickel concentrates using inductively coupled plasma atomic emission spectrometry, Magnesium, calcium content of the method. This part is applicable to the determination of nickel, cobalt, copper, manganese, magnesium and calcium in nickel concentrates. The measurement range (mass fraction) is shown in Table 1. Table 1 Measurement range% (mass fraction) Element determination range Ni 3.0 to 12.0 Co 0.1 to 0.5 Cu 1.0 to 6.0 Mn 0.01 to 0.1 Mg 0.5 to 6.5 Ca 0.5 to 3.0

2 normative reference documents

The following documents are indispensable for the application of this document. For dated references, only the dated edition applies to this article Pieces. For undated references, the latest edition (including all modifications) applies to this document. GB/T 602 Preparation of standard solutions for the determination of impurities in chemical reagents GB/T 6379.2 Accuracy of measurement methods and results (accuracy and precision) - Part 2. Determination of standard measurement methods The basic method of sex and reproducibility GB/T 6682 Analytical laboratory water specifications and test methods GB/T 25952 Sampling and sample preparation method for bulk flotation of nickel concentrates

3 method summary

The sample was decomposed with hydrochloric acid, nitric acid, hydrofluoric acid and perchloric acid, and the salt was dissolved with hydrochloric acid to prepare a sample analysis solution into an inductively coupled plasma The contents of nickel, cobalt, copper, manganese, magnesium and calcium were determined by atomic emission spectrometry.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 4501.1-2016_English be delivered?

Answer: Upon your order, we will start to translate SN/T 4501.1-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 4501.1-2016_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 4501.1-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.