Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

SN/T 2263-2017 English PDF

SN/T 2263: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
SN/T 2263-2017319 Add to Cart 3 days Determination of arsenic, bromine and iodine in coal and coke - Inductively coupled plasma mass spectrometry(ICP-MS) Obsolete
SN/T 2263-2009319 Add to Cart 3 days Determination of arsenic, bromine and iodine in coal and coke. Inductively coupled plasma mass spectrometry(ICP-MS) Obsolete

Similar standards

DL/T 2296   GB/T 2565   SN/T 2697   SN/T 2087.2   SN/T 5576   SN/T 5304   

Basic data

Standard ID: SN/T 2263-2017 (SN/T2263-2017)
Description (Translated English): Determination of arsenic, bromine and iodine in coal and coke - Inductively coupled plasma mass spectrometry(ICP-MS)
Sector / Industry: Commodity Inspection Standard (Recommended)
Classification of Chinese Standard: D21
Classification of International Standard: 73.040
Word Count Estimation: 8,822
Date of Issue: 2017-07-21
Date of Implementation: 2018-03-01
Older Standard (superseded by this standard): SN/T 2263-2009
Quoted Standard: GB/T 474; GB/T 19494.2
Regulation (derived from): National Quality Inspection (2017) No. 337
Issuing agency(ies): General Administration of Customs
Summary: This standard specifies methods for the determination of arsenic, bromine and iodine in coal or coke samples by inductively coupled plasma mass spectrometry. This standard applies to the determination of arsenic, bromine and iodine in coal or coke by inductively coupled plasma mass spectrometry. The measurement range is: arsenic is 0.30mg/kg~200mg/kg; bromine is 50mg/kg~300mg/kg; iodine is 10mg/kg~200mg/kg.

SN/T 2263-2017: Determination of arsenic, bromine and iodine in coal and coke - Inductively coupled plasma mass spectrometry(ICP-MS)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of arsenic, bromine and iodine in coal and coke - Inductively coupled plasma mass spectrometry (ICP-MS) People's Republic of China entry and exit inspection and quarantine industry standards Replace SN/T 2263-2009 Determination of arsenic, bromine and iodine in coal or coke Inductively coupled plasma mass spectrometry Released on.2017-07-21 2018-03-01 implementation People's Republic The General Administration of Quality Supervision, Inspection and Quarantine issued

Foreword

This standard was drafted in accordance with the rules given in GB/T 1.1-2009. This standard replaces SN/T 2263-2009 "Inductively Coupled Plasma Mass Spectrometry for the Determination of Arsenic, Bromine and Iodine in Coal or Coke". versus Compared with SN/T 2263-2009, the main technical changes except editorial changes are as follows. --- Redefined the measurement range of bromine and iodine in the standard; --- Modified "4 reagents and materials" and added "4.4 ammonia"; --- Modified "4 reagents and materials", the cleaning solution was modified to "take 5mL ammonia (4.4), placed in a 500mL plastic volumetric flask, add water Mix" --- Modified "5 instruments" and added "5.4 plastic volumetric flasks, 100mL"; --- Revised "7.4 standard solution working curve drawing", the standard solution concentration was modified to "standard 1.15, 30, 15, 10; standard 2.30, 60, 30, 10; standard 3. 100,.200, 100, 10". This standard is proposed and managed by the National Certification and Accreditation Administration. This standard was drafted. Shanghai Entry-Exit Inspection and Quarantine Bureau of the People's Republic of China. The main drafters of this standard. Zhang Linlin, Xu Jie, Wang Bing, Zhou Haiming, Zhu Zhixiu, Sun Mingxing. The previous versions of the standards replaced by this standard are. ---SN/T 2263-2009. Determination of arsenic, bromine and iodine in coal or coke Inductively coupled plasma mass spectrometry

1 Scope

This standard specifies methods for the determination of arsenic, bromine and iodine in coal or coke samples by inductively coupled plasma mass spectrometry. This standard applies to the determination of arsenic, bromine, and iodine in coal or coke by inductively coupled plasma mass spectrometry. Its measurement range. arsenic 0.30mg/kg~200mg/kg; bromine is 50mg/kg~300mg/kg; iodine is 10mg/kg~200mg/kg.

2 Normative references

The following documents are indispensable for the application of this document. For dated references, only the dated version applies to this article. Pieces. For undated references, the latest edition (including all amendments) applies to this document. Preparation method of GB/T 474 coal sample GB/T 19494.2 Mechanized sampling of coal - Part 2. Preparation of coal

3 method summary

The sample is pre-digested by nitric acid, then subjected to high temperature pressure microwave sealing digestion---mixed acid solution treatment, and then stabilized by the oxidant, diluted After constant volume determination, indium was used as an internal standard for ICP-MS determination. The quantitative relationship between mass-to-charge ratio intensity and its elemental concentration was used to determine arsenic, bromine and iodine in the sample. content.

4 reagents and materials

Unless otherwise stated, this standard uses only analytically pure and above reagents, water is double distilled water or water of comparable purity. If there is a A sub-boiling distilled water can be used. 4.1 Nitric acid (excellent grade, ρ = 1.42g/mL). 4.2 Hydrofluoric acid (analytically pure, HF ≥ 40%). 4.3 Hydrogen peroxide (analytically pure, H2O2 ≥ 30%). 4.4 Ammonia. 4.5 Boric acid. 4.6 Nitric acid (1 1). 4.7 Nitric acid (1/9). 4.8 Tetrafluoroboric acid, 50% (mass fraction). 4.9 sodium persulfate, 10% (mass fraction). Accurately weigh 10 g of sodium persulfate dissolved in 90 mL of water in a beaker and store in a brown reagent bottle. In the middle, the current use is now available. 4.10 Standard storage solution of arsenic. The mass concentration of arsenic is 1000 μg/mL. Direct purchase of a standard substance certificate and within the validity period Elemental standard solution. 4.11 Bromine element standard stock solution. The mass concentration of bromine is 1000μg/mL. Direct purchase of a standard substance certificate and within the validity period Elemental standard solution.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 2263-2017_English be delivered?

Answer: Upon your order, we will start to translate SN/T 2263-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 2263-2017_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 2263-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version SN/T 2263-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 2263-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.