SN/T 2005.4-2006 English PDF

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
SN/T 2005.4-2006319 Add to Cart 3 days Determination of polybromobiphenyls and polybromobiphenyl ethers in electrical and electrical equipment. Part 4: GC/ECD method Obsolete

Similar standards

GB/T 4472   HG/T 3811   GB/T 3143   SN/T 5678   SN/T 5692   SN/T 5494   

Basic data

Standard ID: SN/T 2005.4-2006 (SN/T2005.4-2006)
Description (Translated English): Determination of polybromobiphenyls and polybromobiphenyl ethers in electrical and electrical equipment. Part 4: GC/ECD method
Sector / Industry: Commodity Inspection Standard (Recommended)
Classification of Chinese Standard: G04;L04
Classification of International Standard: 71.040; 31.020
Word Count Estimation: 8,842
Date of Issue: 2006-06-29
Date of Implementation: 2007-01-01
Issuing agency(ies): General Administration of Customs
Summary: This standard specifies the electrical and electronic products, polybrominated biphenyls and polybrominated diphenyl ethers by gas chromatography/electron capture detection (GC/ECD) method. This standard applies to electrical and electronic products, polybrominated biphenyls and polybrominated diphenyl ethers determination.

SN/T 2005.4-2006: Determination of polybromobiphenyls and polybromobiphenyl ethers in electrical and electrical equipment. Part 4: GC/ECD method


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Determination of polybromobiphenyls and polybromobiphenyl ethers in electrical and electrical equipment. Part 4. GC/ECD method Book of the People's Republic of China Entry and Exit Inspection and Quarantine Polybrominated biphenyls in electrical and electronic products And determination of polybrominated diphenyl ethers Part 4. Gas Chromatography/Electron Capture Detector Method Released on June 26,.2006 2007-01-01 implementation People's Republic The General Administration of Quality Supervision, Inspection and Quarantine issued

Foreword

This part is the fourth part of SN/T 2005. Appendix A and Appendix B of this section are informative annexes. This part is proposed and managed by the National Certification and Accreditation Administration. This part is drafted by the Jiangsu Entry-Exit Inspection and Quarantine Bureau. The main drafters of this section. Gu Gaolang, Lu Zhengqing, Zhu Weijuan, Yuan Ronggen, Ye Chunyan. This section is the first industry standard for entry-exit inspection and quarantine. Polybrominated biphenyls in electrical and electronic products And determination of polybrominated diphenyl ethers Part 4. Gas Chromatography/Electron Capture Detector Method

1 Scope

This section specifies gas chromatography/electron capture detectors (GC/ECD) for polybrominated biphenyls and polybrominated diphenyl ethers in electrical and electronic products. Method. This section applies to the determination of polybrominated biphenyls and polybrominated diphenyl ethers in electrical and electronic products.

2 Terms and definitions

The following terms and definitions apply to this section. 2.1 The structural formula of polybrominated biphenyl is shown in Figure 1. Figure 1 Structure of polybrominated biphenyl There are a total of 209 isomers of polybrominated biphenyls depending on the number and position of bromine atoms on the benzene ring. 2.2 The structural formula of PBDE is shown in Figure 2. Figure 2 Structure of polybrominated diether There are a total of 209 isomers of PBDEs depending on the number and position of bromine atoms on the benzene ring.

3 Method summary

The sample was extracted by Soxhlet using toluene as the extraction solvent. The extract was purified, separated by silica gel column, concentrated, and processed by GC/ECD. Line analysis.

4 reagents and materials

4.1 Toluene. chromatographically pure.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 2005.4-2006_English be delivered?

Answer: Upon your order, we will start to translate SN/T 2005.4-2006_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 2005.4-2006_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 2005.4-2006_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.