SN/T 1431.3-2011 English PDFUS$239.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 1431.3-2011: Rules for the inspection of low-voltage electrical apparatus for import and export. Part 3: Residual current cooperated circuit-breakers for household and similar uses Status: Valid SN/T 1431.3: Historical versions
Basic dataStandard ID: SN/T 1431.3-2011 (SN/T1431.3-2011)Description (Translated English): Rules for the inspection of low-voltage electrical apparatus for import and export. Part 3: Residual current cooperated circuit-breakers for household and similar uses Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: L24 Classification of International Standard: 29.120.30 Word Count Estimation: 9,935 Date of Issue: 2011-09-09 Date of Implementation: 2012-04-01 Older Standard (superseded by this standard): SN/T 0996-2001 Quoted Standard: GB/T 2828.1-2003; GB/T 2900.18-2008; GB 16916.1-2003; GB 16917.1-2003; SN/T 0002 Regulation (derived from): National-Quality-Inspection-accreditation (2011) 492; Industry Standard Filing Announcement 2012 No.4 (Total No.148) Issuing agency(ies): General Administration of Customs Summary: This standard specifies the import and export of household and similar sampling residual current operated circuit breaker, inspection and the results of the determination. This section applies to AC 50Hz (or 60Hz), voltage not exceeding 440V, rated current not exceeding 125A of the household or residual current operated circuit breaker testing purposes similar. This section does not apply to the following products test: The battery RCCB, for motor protection RCBO, setting current value by the user in the use of self-regulation of the RCBO. SN/T 1431.3-2011: Rules for the inspection of low-voltage electrical apparatus for import and export. Part 3: Residual current cooperated circuit-breakers for household and similar uses---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Rules for the inspection of low-voltage electrical apparatus for import and export.Part 3. Residual current cooperated circuit-breakers for household and similar uses People's Republic of China Entry-Exit Inspection and Quarantine Standards Instead of the SN/T 0996-2001 Low-voltage electrical inspection of import and export Part 3. Household and similar residual current operated breaker andexport-Part 3. Residualcurrentcooperatedcircuit-breakersfor Issued on. 2011-09-09 2012-04-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released ForewordSN/T 1431 "Importers and low-voltage electrical inspection procedures" series of standards is divided into five parts. --- Part 1. General requirements; --- Part 2. Household and similar circuit breakers for overcurrent protection; --- Part 3. Household and similar residual current operated circuit breaker; --- Part 4. Electromechanical contactors and motor starters; --- Part 5. low voltage fuses. This is Part 3 SN/T 1431 "Importers and low-voltage electrical inspection procedures" series of standards. This section based on GB/T 1.1-2009 write drafted. Some of this section may involve patents, this part of the release mechanism does not assume the responsibility to identify these patents. The partial replacement of SN/T 0996-2001, compared with the SN/T 0996-2001 The main changes are as follows. --- Examine the contents of the deleted original packaging procedures, shape and installation manual testing, electromagnetic compatibility test, delete, and modify some of the Visual inspection contents; --- Increasing the consistency test project, assembly quality inspection; --- Modify the flag checking the contents of the original dielectric strength test procedure to test dielectric properties, and to increase the inspection auxiliary circuit Seeking original statutes overcurrent protection characteristics test (if applicable) to modify the overcurrent tripping characteristic and increase its requirements in Table 3 Detailed description of the operating characteristics of the original statutes to Residual Current Operating Characteristic (no-load); --- Table 2. visual inspection of the surface of the product failed to Category B, over-current operating characteristics of substandard classification according to different projects Divided into Class A and Class B; --- Increased content inspection and supervision mode and test mode. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section drafted by. People's Republic of China Zhejiang Exit Inspection and Quarantine. The main drafters of this section. Yujin Jun, Xu comedy, Lu Yang, Wang Jianxin. This part of the standard replaces the previous editions are. --- SN/T 0996-2001.Introduction"Importers and low-voltage electrical inspection of" low-voltage electrical products import and export inspection work basis, import and export of low-voltage electrical products Inspection play a guiding and regulating. With China's accession to the World Trade Organization (WTO) and the revised "People's Republic of China Import and Export Commodity Inspection Law" Import and Export Commodity Inspection Test mode has undergone great change, to adapt to changes in the situation and to meet the actual needs of inspection and quarantine work, Inspection and Quarantine of the competent Inspection and quarantine departments to establish a standard system. This part belongs to the standard system of inspection and quarantine fourth floor --- personality standard that specifies the import and export of household and similar residual current operated Breaker inspection requirements. Low-voltage electrical inspection of import and export Part 3. Household and similar residual current operated breaker1 ScopeThis section provides a sample import and export of household and similar residual current operated circuit breaker, test results and determination. This section applies to AC 50Hz (or 60Hz), voltage does not exceed 440V, rated current not exceeding 125A household or similar purposes Inspection of residual current operated circuit breaker. This section does not apply to product testing. --- Using battery RCCB; --- For motor protection RCBO; --- Setting current value by the user in the use of self-regulation of RCBO.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 2828.1-2003 Sampling procedures for inspection - Part 1. Press to accept the quality limit (AQL) retrieval batch test sample Programme (ISO 2859-1.1999, IDT) GB/T 2900.18-2008 Electrotechnical term low-voltage electrical (RCCB) Part 1 GB 16916.1-2003 household and similar uses overcurrent protection for residual current operated circuit breaker Score. General rules (IEC 61008-1.1996, MOD) GB 16917.1-2003 household and similar uses overcurrent protection for residual current operated circuit breaker (RCBO) (IEC 61009-1.1996, MOD) The basic provisions of SN/T 0002 Electromechanical Import and Export Commodity Inspection procedures prepared3 Terms and DefinitionsGB/T 2828.1-2003, GB/T 2900.18-2008, GB 16916.1-2003, GB 16917.1-2003 and SN/T 0002 Defining the following terms and definitions apply to this document. 3.1 Sampling mode modeofsamplinginspection According to the mandatory requirements of national technical specifications, batch import and export commodities or pumping grant implementation sampling, testing and inspection of conformity assessment activities. 3.2 Type Test mode modeoftypetest According to a predetermined cycle based on the mandatory requirements of national technical specifications type testing, according to on-site inspection requirements for product pumping batch inspection Inspection, supervision and implementation of the conformity assessment activities of the enterprise quality management system. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 1431.3-2011_English be delivered?Answer: Upon your order, we will start to translate SN/T 1431.3-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 1431.3-2011_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 1431.3-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version SN/T 1431.3-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 1431.3-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |