Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

SN/T 0067-2012 English PDF

US$1479.00 · In stock
Delivery: <= 8 days. True-PDF full-copy in English will be manually translated and delivered via email.
SN/T 0067-2012: Mechanical method for sampling and sample preparation of coal for import and export
Status: Valid

SN/T 0067: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
SN/T 0067-20121479 Add to Cart 8 days Mechanical method for sampling and sample preparation of coal for import and export Valid
SN 0067-1992RFQ ASK 9 days Mechanical method for sampling and samplepreparation of coal for export Obsolete

Similar standards

MT/T 199   MT 209   HAD 002/02   

Basic data

Standard ID: SN/T 0067-2012 (SN/T0067-2012)
Description (Translated English): Mechanical method for sampling and sample preparation of coal for import and export
Sector / Industry: Commodity Inspection Standard (Recommended)
Classification of Chinese Standard: D98
Word Count Estimation: 60,682
Older Standard (superseded by this standard): SN 0067-1992
Quoted Standard: GB 475; GB/T 3715
Adopted Standard: ISO 13909-1-2001, NEQ; ISO 13909-2-2001, NEQ; ISO 13909-4-2001, NEQ; ISO 13909-7-2001, NEQ; ISO 13909-8-2001, NEQ
Regulation (derived from): National Quality Inspection (2012) 643; industry standard filing Notice 2013 No. 1 (No. 157 overall)
Issuing agency(ies): General Administration of Customs
Summary: This standard specifies the terms and definitions of mechanized coal import and export Sampling methods, develop sampling programs, sampling, sample preparation, packaging and labeling of coal samples, Sampling design of mechanical systems and so on. This

SN/T 0067-2012: Mechanical method for sampling and sample preparation of coal for import and export


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Mechanical method for sampling and sample preparation of coal for import and export People's Republic of China Entry-Exit Inspection and Quarantine Standards Replacing SN 0067-1992 Import and export of coal mechanization sampling sample preparation method Issued on. 2012-10-23 2013-05-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released

Table of Contents

Introduction Ⅲ 1 Scope 1 2 Normative references 1 3 Terms and definitions Sampling scheme to develop 44 5 Sampling Method 8 6 sample preparation method 10 7 coal sample labeling and marking 18 Mechanical Sampling System Design 8 of 18 Technical guidance to Appendix A (informative) Mechanical Sampling System operation 26 Appendix B (normative) to determine the primary sub-sample variance with multiple sampling methods and verification precision approach 27 Verification method Appendix C (normative) sample preparation error 32 Annex D (normative) Test Method 41 bias

Foreword

This standard was drafted in accordance with GB/T 1.1-2009 given rules. This standard replaces SN 0067-1992 "export coal mechanical sampling sample preparation method." This standard compared with SN 0067-1992, the main technical changes are as follows. --- All terms and definitions have been updated; --- Adjust the original standard narrative structure; --- Deleted the original standard application look-up table, change the formula method; --- Original standard part of the narratives of editorial changes to the text. The reference standard ISO 13909-1.2001 "coal and coke - Mechanical sampling - Part 1. Introduction", ISO 13909-2.2001 "Hard coal and coke - Mechanical sampling - Part 2. Mobile coal flow sampling", ISO 13909-4.2001 "mechanized mining coal and coke Comp - Part 4. Sample Preparation ", ISO 13909-7.2001" coal and coke - Mechanical sampling - Part 7. Sampling, sample preparation and testing Precision measurement method ", ISO 13909-8.2001" coal and coke - Mechanical sampling - Part 8. Test methods for bias, "the main internal Yung. This standard is consistent with the aforementioned standard non-equivalent, the main differences are as follows. --- To maintain the original structure and SN standard level; --- Remove the belt and the flow of coal flow sampling irrelevant content. This standard is proposed and managed by the National Certification and Accreditation Administration Committee. This standard was drafted. People's Republic of China Exit Inspection and Quarantine of Hebei, People's Republic of China Guangdong Entry-Exit Inspection and Quarantine Bureau. The main drafters of this standard. Dong Feng, Tian Hao, Zhong Zhiguang. This standard replaces the standards previously issued as follows. --- SN 0067-1992. Import and export of coal mechanization sampling sample preparation method

1 Scope

This standard specifies the terms and definitions developed mechanized coal import and export Sampling methods, sampling programs, sampling, sample preparation, coal Packaging and labeling, and other mechanical design Sampling System. This standard applies to the import and export of coal coal samples taken from the transport belt of coal flow.

2 Normative references

The following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB 475 coal samples of goods taken by artificial methods GB/T 3715 coal quality and coal analysis related terms

3 Terms and Definitions

GB/T 3715 defined by the following terms and definitions apply to this document. 3.1 Coal coalsample In order to determine certain characteristics of the coal taken from a representative portion of the coal. 3.2 Test coal testsampleofcoal To meet the coal requirements of a particular test sample was prepared. 3.3 Total coal sample commonsampleofcoal For a variety of tests taken by coal. 3.4 Particle size analysis of coal samples sizeanalysissampleofcoal For particle size analysis of coal samples taken specifically. 3.5 Total moisture coal moisturesampleofcoal Specifically for the determination of total moisture in coal sample taken. 3.6 General analysis test sample general-analysistestsampleofcoal coal According to the method prescribed crushed to a particle size of less than 0.2mm and reach the air-dried state for determination of physical and chemical characteristics of coal samples. 3.7 Sampling sampling Take a representative part of the process of coal from a large coal.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of SN/T 0067-2012_English be delivered?

Answer: Upon your order, we will start to translate SN/T 0067-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 5 ~ 8 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of SN/T 0067-2012_English with my colleagues?

Answer: Yes. The purchased PDF of SN/T 0067-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version SN/T 0067-2012?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 0067-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.