SN/T 0065.3-2011 English PDFUS$159.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. SN/T 0065.3-2011: Method for determination of europium-rich, yttrium-rich, Sm-Eu-Gd oxides for import and export. Part 3: Determination of total rare earth oxides content Status: Valid SN/T 0065.3: Historical versions
Basic dataStandard ID: SN/T 0065.3-2011 (SN/T0065.3-2011)Description (Translated English): Method for determination of europium-rich, yttrium-rich, Sm-Eu-Gd oxides for import and export. Part 3: Determination of total rare earth oxides content Sector / Industry: Commodity Inspection Standard (Recommended) Classification of Chinese Standard: D41 Classification of International Standard: 73.060.99 Word Count Estimation: 6,626 Date of Issue: 2011-02-25 Date of Implementation: 2011-07-01 Older Standard (superseded by this standard): SN 0065.3-1992 Quoted Standard: GB/T 6379.2 Regulation (derived from): ?AQSIQ-Inspection [2011] 90 Issuing agency(ies): General Administration of Customs Summary: This standard specifies the import and export of rich europium, determination of europium, gadolinium and samarium, yttrium -rich oxides of total rare earth oxides. This section applies to the import and export rich europium, determination of yttrium and samarium -rich rare earth oxides of europium, gadolinium oxide in total. Measuring range: 85% to 99%. SN/T 0065.3-2011: Method for determination of europium-rich, yttrium-rich, Sm-Eu-Gd oxides for import and export. Part 3: Determination of total rare earth oxides content---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Method for determination of europium-rich, yttrium-rich, Sm-Eu-Gd oxides for import and export Part 3. Determination of total rare earth oxides content People's Republic of China Entry-Exit Inspection and Quarantine Standards Replacing SN 0065.3-1992 Importers and rich europium, yttrium-rich, samarium, europium, gadolinium oxide determination Part 3. Determination of total rare earth oxides Methodfordeterminationofeuropium-rich, yttrium-rich, Sm-Eu-Gd Part 3. Determinationoftotalrareearthoxidescontent Issued on. 2011-02-25 2011-07-01 implementation People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine released ForewordSN/T 0065 "Importers rich europium, yttrium-rich, samarium, europium, gadolinium oxide measurement method" standard series is divided into three parts. --- Part 1. Determination of moisture --- Part 2. Determination of loss on ignition --- Part 3. Determination of total rare earth oxides This section SN/T Section 30065 of. This Part replaces SN 0065.3-1992 "Importers rich europium, yttrium-rich, oxygen measuring samarium rare earth europium, gadolinium oxide measurement method --- gravimetric method The total amount of compounds. " ". Chemical analysis methods - Part 4 standard writing rules" provisions of this section in accordance with SN 0065.3-1992 GB/T 20001.4 Be revised. This section compared with SN 0065.3-1992 main changes are as follows. --- Add a description of the preamble; --- Delete the obsolete GB 4471 "between Chemical test method precision laboratory tests to determine the repeatability and reproducibility"; --- Given precision repeatability limit, the reproducibility of the method has been covered limit measurement range, delete the original standard "8.2 critical difference calculation" Terms. This section proposed and managed by the National Certification and Accreditation Administration Committee. This section was drafted by. People's Republic of China Guangdong Entry-Exit Inspection and Quarantine of Liaoning People's Republic of China Bureau, People's Republic of China Foshan Entry-Exit Inspection and Quarantine Jiangmen People's Republic of China, People's Republic of China Zhanjiang CIQ. The main drafters of this section. Zhong Zhiguang, Cao Xiaoyan, of Interferon Gu Changsheng Tian Qiong, Zhong Pei Yu, Huang Wenxian, sails, Lu Zhenguo, Zhangzhen Kun, Peng-speed standard, Zheng Jianguo, Li Jinxing. This part of the standard replaces the previous editions are. --- SN 0065.3-1992. Importers and rich europium, yttrium-rich, samarium, europium, gadolinium oxide determination Part 3. Determination of total rare earth oxides1 ScopeSN/T 0065 provisions of this part of the determination of the total import and export rich rare earth oxides of europium, samarium and europium yttrium-rich gadolinium oxide. This section applies to the import and export rich europium, Determination of total rare earth oxides of yttrium and rich europium, gadolinium, samarium oxide. Measuring range. 85% to 99%.2 Normative referencesThe following documents for the application of this document is essential. For dated references, only the dated version suitable for use herein Member. For undated references, the latest edition (including any amendments) applies to this document. GB/T 6379.2 measurement methods and results of Accuracy (trueness and precision) - Part 2. Determine the standard measurement method to repeat Of the basic methods of reproduction3 Method summarySample nitric acid - perchloric acid was dissolved and dehydrated, and insolubles were removed by filtration silicon. The filtrate was precipitated with ammonia rare, adding gelatin Cohesion rare, rare earth and calcium, magnesium, titanium separation. RE oxalic acid precipitation, and further separation of iron, aluminum and other non-rare earth impurities. The precipitate was filtered, Ash and burning, rare earth oxides in the form of weighing.4 ReagentsUnless otherwise indicated in the analysis using only recognized as analytical grade reagents and distilled or deionized water. 4.1 perchloric acid (ρ1.67g/mL). Nitrate 4.2 (ρ1.42g/mL). 4.3 hydrochloride (ρ1.19g/mL). Hydrochloride 4.4 (volume fraction 149). 4.5 Hydrogen peroxide (ρ1.10g/mL). 4.6 gelatin (10g/L). Weigh 1g gelatin dissolved in 100mL hot water preparation today. 4.7 Ammonia (ρ0.9g/mL). 4.8 aqueous ammonia (volume fraction 11). 4.9 ammonia - ammonium chloride bath. Weigh 2g of ammonium chloride dissolved in 90mL water, 10mL plus ammonia (see 4.7), pH≥9.2. 4.10 oxalic acid solution (90g/L). Weigh 90g of oxalic acid dissolved in 1000mL water. 4.11 oxalic acid lotion (20g/L). Weigh 20g of oxalic acid dissolved in 1000mL water. 4.12 cresol red indicator (1g/L). Weigh cresol red 0.1g, plus ethanol 20mL dissolved, diluted with water to 100mL, and mix.5 Instruments5.1 Analysis of balance. a sense of the amount of 0.1mg. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of SN/T 0065.3-2011_English be delivered?Answer: Upon your order, we will start to translate SN/T 0065.3-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of SN/T 0065.3-2011_English with my colleagues?Answer: Yes. The purchased PDF of SN/T 0065.3-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version SN/T 0065.3-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version SN/T 0065.3-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |