MT 62-1997 English PDFUS$239.00 · In stock
Delivery: <= 2 days. True-PDF full-copy in English will be manually translated and delivered via email. MT 62-1997: Test method and judge rules of safety of permissible electric detonator for coal mining in firedamp Status: Obsolete MT 62: Historical versions
Basic dataStandard ID: MT 62-1997 (MT62-1997)Description (Translated English): Test method and judge rules of safety of permissible electric detonator for coal mining in firedamp Sector / Industry: Coal Industry Standard Classification of Chinese Standard: G89 Classification of International Standard: 71.100.30 Word Count Estimation: 6,624 Date of Issue: 12/12/1997 Date of Implementation: 2/1/1998 Older Standard (superseded by this standard): MT 62-1982 Quoted Standard: GB/T 8031-1987 Regulation (derived from): State Administration of Work Safety & Supervision Notice 2014 No. 7 Summary: This standard specifies the coal mine gas Xu electricity detonator safety test instruments, equipment, test conditions, test procedures and decision rules. This standard applies to electrical detonator mines promise. MT62:---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Test method and judge rules of safety of permissible electric detonator for coal mining in firedamp ICS 71.100.30 G89 People's Republic of China Coal Industry Standard MT/T 62-1997 Underground Combustible Gas Safety of Permissible Electric Detonator in Coal Mine Test methods and judgment rules Test method and judge rules of safety of permissible electric detonator for coal mining in firedamp 1997-12-12 Released.1998-02-01 implemented Issued by the Ministry of Coal Industry of the People's Republic of China ContentsForeword Ⅱ 1 Scope 1 2 Normative references 1 3 Method summary 1 4 Instruments, equipment and materials 1 5 Test conditions 2 6 Test step 2 7 Judgment Rule 2 MT/T 62-1997ForewordThis standard is a standard for the coal industry MT 62-82 Amendments to the "Regulations on the Safety of Coal Mine Permissible Electric Detonators and Their Inspection Methods". This standard will replace MT from the effective date 62-82. This standard is proposed by the Department of Science, Technology and Education of the Ministry of Coal Industry. This standard is under the jurisdiction of the Coal Mine Safety Standardization Technical Committee of the Ministry of Coal Industry. This standard was drafted. Fushun Branch of China Coal Research Institute. Drafters of this standard. Fu Baocan, Cui Yingzhang, Ma Bingtian, Liu Guohua, Han Bin. This standard entrusts Fushun Branch of the General Research Institute of Coal Science to be responsible for interpretation. MT/T 62-1997 Underground Combustible Gas Safety of Permissible Electric Detonator in Coal Mine Test methods and judgment rules1 ScopeThis standard specifies the instruments, equipment, test conditions, test procedures and judgments for coal mine allowable electric detonators for underground gas safety testing. rule. This standard applies to electric detonators permitted in coal mines.2 Reference standardsThe following standards contain provisions that, through reference in this standard, constitute provisions of this standard. When this standard was published, the editions shown were all Is effective. All standards will be revised, and all parties using this standard should explore the possibility of using the latest versions of the following standards. GB/T 8031-87 Industrial Electric Detonator3 Method summaryDetonate the electric detonator under test in a specific device filled with a downhole combustible gas-air mixture to detonate the gas mixture The number indicates the safety of the electric detonator to combustible gas. 4 Instruments, equipment and materials 4.1 The explosion box is rolled from steel. Diameter 560 mm, length 1200 mm. One end is closed with a steel plate, and gas mixing pipes on both sides, The air inlet and methane detection port are shown in Figure 1. 1- explosion box; 2- thermometer; 3- methane detection port; 4- fixed detonator bracket; 5- sealing gasket; 6-sealed door; 7-handle; 8-intake valve; 9-exhaust valve; 10-fan; 11-gas mixing pipeline; 12-manual valve; 13-combustible gas inlet valve; 14-air inlet1 Schematic diagram of underground gas safety test device4.2 Methane detector. The division value should not be greater than 0.02%. MT/T 62-1997 4.3 Thermometer. The division value should not be greater than 1 ℃. 4.4 Detonation power. The power supply time should not exceed 4 ms. 4.5 Downhole flammable gas for test. Must use the downhole flammable gas approved by the Ministry of Coal Industry. When testing, when the methane concentration is At 9.0%, the total content of other combustible gases should be no more than 0.3%, and the total content of carbon dioxide and excess nitrogen should be no more than 1.0%.5 Test conditions5.1 The methane concentration in the combustible gas-air mixed gas in the explosion chamber is (9.0 ± 0.3)%. 5.2 The temperature in the explosion box is (20 ± 10) ℃, and the relative humidity should not be greater than 80%. 5.3 Permissible electric detonators in the tested coal mine shall comply with GB/T Only after the specifications, quality and explosive performance indicators specified in the 8031 standard can the underground be carried out Flammable safety test.6 Test steps6.1 Connect the gas inlet of the explosion box to a hose and connect it to a steel cylinder filled with downhole gas. 6.2 Connect the methane detector to the methane detection port. 6.3 Prior to the test, the test sample should be tested with a pyrotechnic tip or an unallowable electric detonator to verify that the test system is normal. 6.4 The first detonator to be tested is horizontally fixed in the center of the explosion box fixing bracket, with the bottom of the tube facing the mouth of the box. 6.5 The open end of the explosion box is closed with kraft paper or plastic film. 6.6 Open the flammable gas inlet valve and the methane detection port valve to fill the downhole flammable gas in the explosion box, and at the same time, start the fan to mix to make the explosion The methane content in the fryer has reached the required concentration. 6.7 Close the valves at 3, 8, 9, 12, and 13 in Figure 1. 6.8 Immediately detonate the detonator under test with an initiating power source. According to the explosion sound or other parameters, determine whether the detonator detonates the gas-air Compound and make a record.7 Decision rules7.1 There are 25 rounds of samples in each group, and the detonation frequency is not more than 1/25 to be qualified. If the detonation frequency is 2/25, add 25 trials, and the total detonation frequency No more than 2/50 is still qualified. 7.2 Coal mine allowable millisecond extension of electric detonators, each section as a group for testing. MT/T 62-1997 ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of MT 62-1997_English be delivered?Answer: Upon your order, we will start to translate MT 62-1997_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 2 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of MT 62-1997_English with my colleagues?Answer: Yes. The purchased PDF of MT 62-1997_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version MT 62-1997?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version MT 62-1997 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |