JJG 981-2014: Standard Blocks for Abbe Refractometers
Status: Valid

JJG 981: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJG 981-2014489 Add to Cart 4 days Standard Blocks for Abbe Refractometers Valid
JJG 981-2003759 Add to Cart 5 days Verification Regulation of Standard Blocks for Abbe Refractometers Obsolete

Similar standards

JJG 879   JJF 1106   JJG 810   JJG 452   JJG 512   JJG 211   

Basic data

Standard ID: JJG 981-2014 (JJG981-2014)
Description (Translated English): Standard Blocks for Abbe Refractometers
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A60
Classification of International Standard: 17.180
Word Count Estimation: 21,286
Date of Issue: 2/14/2014
Date of Implementation: 8/14/2014
Older Standard (superseded by this standard): JJG 981-2003
Quoted Standard: JJG 625-2001; JJG 863-2005; GB 7962.1-2010; GB/T 26397-2011
Regulation (derived from): AQSIQ Announcement No. 17 of 2014
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard specifies the initial verification Abbe refractometer standard block, subsequent verification and the use of checks.

JJG 981-2014: Standard Blocks for Abbe Refractometers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Standard Blocks for Abbe Refractometers State verification procedures People's Republic of China Abbe refractometer Standard Blocks Issued on. 2014-02-14 2014-08-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Abbe refractometer standard block verification procedures Replacing JJG 981-2003 Focal point. the National Technical Committee on Optical metrology The main drafting units. China Institute of Metrology Participated in the drafting unit. China Testing Technology Research Institute Changchun City Jinlong Optoelectronics Technology Co., Ltd. This procedure committee commissioned by the National Optical measurement technology is responsible for interpreting The main drafters of this procedure. Liu Wenli (China Institute of Metrology) Yang Lei (China Institute of Metrology) Drafters participate. Li Fei (China Institute of Metrology) Li Xiaobin (China Testing Technology Research Institute) Xuwen lei (Changchun Jinlong Optoelectronics Technology Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Terms (1) Refractive index of 3.1 (1) 3.2 Dispersion (1) 3.3 Abbe number (1) 3.4 Abbe refractometer (1) 3.5 V prism refractometer (2) 4 Overview (2) 5 metering performance requirements (2) 5.1 standard block refractive index value (2) 5.2 standard block average dispersion value (3) 6 General Requirements (3) 6.1 Appearance (3) 6.2 Maintenance (3) Geometry 6.3 (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 Verification Project (4) 7.3 Verification Methods (4) 7.4 Verification Results Processing (6) 7.5 test cycle (6) Appendix A common method of preparation and the refractive index of refraction of the liquid (7) Appendix B Abbe refractometer calibration standard block format recommended by the original record (8) Appendix C Abbe refractometer standard block calibration certificate, test results notice (inside) recommended format (10) Appendix D refractive index (nD) Measurement of Uncertainty Evaluation (11) Appendix E average dispersion (nF-nC) Measurement of Uncertainty Evaluation (14)

Introduction

This procedure is based on the JJG 981-2003 reference JJF1002-2010 "national verification procedures compiled Write Rules "re-revised. Compared with JJG 981-2003, except in accordance with section JJF1002-2010 made constitution And modify the formatting on the outside, the main technical changes are as follows. --- Increasing the reference document (see Chapter 2); --- Increasing the term (see Chapter 3); --- Increase the measuring instruments in control of "the refractive index of the glass material standard block" requirements (see 7.1.1.4); --- Modify the measurement sequence verification method (see 7.3.3); --- Increase the verification process reads the V prism refractometer real time correction value d requirements (see 7.3.3.5); --- Modify the original record test recommended format (see Appendix B); --- Adjustment Appendix order. The previous versions of this Recommendation published case. --- JJG 981-2003. Abbe refractometer standard block verification procedures

1 Scope

The order applies to the standard blocks Abbe refractometer initial verification, use and subsequent verification check. 2. References This procedure references the following documents. JJG 625-2001 Abbe refractometer JJG 863-2005 V prism refractometer GB 7962.1-2010 Colourless optical glass test methods - Part 1. refractive index and Abbe number GB/T 26397-2011 Ophthalmic optics terminology For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.

3 Terms

The following terms and definitions apply to this procedure. 3.1 refractive index n (λ) refractiveindex Electromagnetic wave velocity in a vacuum with a monochromatic radiation of different wavelengths in the medium than the corresponding speed. Note. A practical application, the air velocity in a vacuum instead of speed. Helium is usually a refractive index of the yellow line d 2 of the optical material (wavelength λ of 587.56) or refractive index nd mercury green line e (wavelength λ As 546.07nm) refractive index to represent. 3.2 Dispersion dispersion Monochromatic radiation of different wavelengths in the refractive index of the medium changes due to the different wavelengths of the phenomenon. 3.3 Abbe number vd Abbenumber Also known as chromatic dispersion coefficient is a mathematical expression characterizing optical material dispersion phenomena, usually with vd = nd-1nF-nC Or ve = ne-1nF'-nC ' To represent. Note. 1 nd helium yellow line d (wavelength λ is 587.56nm) refractive index; nF hydrogen blue line F (wavelength λ is 486.13nm) of nC hydrogen red line C (wavelength λ is 656.27nm) refractive index; refractive index. ne mercury green line e (λ is the wavelength 546.07nm) refractive index; nF 'cadmium blue line F' (λ is the wavelength 479.99nm) refractive index; nC 'mercury red line C' (Wavelength λ of 643.85nm) of the refractive index. 2 (nF-nC) called average dispersion, also called the central dispersion. 3.4 Abbe refractometer Abberefractometer Using the principle of total reflection critical angle, measured transparent, translucent liquid or solid refractive index (nD) and average Dispersion (nF-nC) of the instrument. Equipped with a calibration sample block is called work sample block. Note. nD sodium yellow line D (wavelength λ is 598.30nm) index of refraction.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 981-2014_English be delivered?

Answer: Upon your order, we will start to translate JJG 981-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 981-2014_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 981-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 981-2014?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 981-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.