JJG 962-2010 English PDFUS$329.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 962-2010: Verification regulation of personal dose equivalent rate warning devices for X and γ radiation Status: Valid JJG 962: Historical versions
Basic dataStandard ID: JJG 962-2010 (JJG962-2010)Description (Translated English): Verification regulation of personal dose equivalent rate warning devices for X and �� radiation Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A58 Classification of International Standard: 17.240 Word Count Estimation: 14,147 Date of Issue: 2010-09-06 Date of Implementation: 2011-03-06 Older Standard (superseded by this standard): JJG 962-2001 Quoted Standard: GB/T 14323-1993; IEC 61344-1996; IEC 61526-2005; ICRU REPORT 47-1992; GB/T 12162.1-2000; GB/T 12162.2-2004; GB/T 12162.3-2004 Regulation (derived from): AQSIQ Announcement No. 100 of 2010 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to worn on the torso using a stereo or sound and light style strongly penetrating X, �� radiation personal dose equivalent rate alarm device initial verification, testing and use of follow-up inspection. X, �� radiation energy range of 50keV ~ 1. 5MeV. If the alarm device intended for measurement of higher energy (up to 10MeV) photon dose equivalent rate generated, you must determine the appropriate energy on its response. This procedure does not apply to weakly penetrating X, �� radiation personal dose equivalent rate Hp (0. 07) of the instrument with alarm verification. This procedure does not apply to individual neutrons and �� radiation alarm device testing. JJG 962-2010: Verification regulation of personal dose equivalent rate warning devices for X and γ radiation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Verification regulation of personal dose equivalent rate warning devices for X and γ radiation State verification procedures People's Republic of China X, γ radiation personal dose equivalent rate alarm Issued on. 2010-09-06 2011-03-06 implementation The State Administration of Quality Supervision, Inspection and Quarantine released X, γ radiation personal dose equivalent rate alarm Verification Regulation Radiation Replacing JJG 962-2001 The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on September 6, 2010, and from From March 6, 2011 into effect. Focal point. the National Technical Committee of ionizing radiation metrology Drafting. Shanghai Institute of Measurement and Testing This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The drafters of the regulations. Chen Jianxin (Shanghai Institute of Measurement and Testing) Liyan Fei (Shanghai Institute of Measurement and Testing) table of Contents1 Scope (1) 2. Referenced Documents (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (2) 4 Overview (2) 5 metering performance requirements (3) 6 General Requirements (3) 6.1 Appearance (3) 6.2 General Requirements (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 Verification Project (5) 7.3 Verification Methods (5) 7.4 Verification Results Processing (6) 7.5 test cycle (6) Appendix AX reference radiation characteristics and the Conditions (7) Appendix B calibration certificate and test results in the notice page format (8) X, γ radiation personal dose equivalent rate alarm Verification Regulation1 ScopeThe order applies to wear stereo sound on the torso or the use of light intensity through the formula X, γ radiation personal dose equivalent Alarm volume ratio of initial verification, subsequent verification and in-service inspection. X, γ radiation energy range of 50keV ~ 1.5MeV. If the alarm device intended for measuring higher energy Dose equivalent rate (up to 10MeV) photons generated, it must determine the response on the appropriate energy. This procedure does not apply to weakly penetrating X, γ radiation personal dose equivalent rate H P (0.07) of the alarm verification. This procedure does not apply to neutron radiation and β personal alarm verification.2 CitationsThe regulations cited in the following documents. GB/T 14323-1993 X, γ radiation personal alarm device IEC 61344-1996. Radiationprotectioninstrumentation-Monitoringequipment- PersonalwarningdevicesforXandgammaradiations (radiation protection monitoring equipment --- --- instrument Personal alarm devices for X and γ radiation) (1996) IEC 61526-2005. Radiationprotectioninstrumentation-Measurementofpersonal doseequivalentHP (10) andHP (0.07) forX, gamma, neutronandbetaradiation-Di- rectreadingpersonaldoseequivalentmetersandmonitors (radiation protection instruments --- for X, Personal γ, neutrons and β radiation measurement equivalent HP (10) and HP (0.07) measurement --- Direct reading personal measurement when Meter and monitor) ICRU Report47. Measurementofdoseequivalentfrom externalphotonand electronradiations (external beam photon and electron radiation measurement equivalents measure) (1992) X and γ GB/T 12162.1-2000 for calibrating dosemeters and dose rate meters and for determining their response parameters Test radiation - Part 1. Radiation characteristics and production methods X and γ GB/T 12162.2-2004 for calibrating dosemeters and dose rate meters and for determining their response parameters Test - Radiation - Part 2. Radiation protection over the energy range 8keV ~ 1.3MeV and 4MeV ~ 9MeV of Reference radiation dosimetry X and γ GB/T 12162.3-2004 for calibrating dosemeters and dose rate meters and for determining their response parameters Determination place dosimeters and personal dosimeters calibrated response and its energy and angular response. test - Radiation - Part 3 When using this procedure, it should pay attention to the current valid version of the above-mentioned documents.3 terminology and units of measurement3.1 Terms ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 962-2010_English be delivered?Answer: Upon your order, we will start to translate JJG 962-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 962-2010_English with my colleagues?Answer: Yes. The purchased PDF of JJG 962-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 962-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 962-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |