Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 960-2012 English PDF

US$489.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 960-2012: Verification Regulation of Level Verification System
Status: Valid

JJG 960: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJG 960-2012489 Add to Cart 4 days Verification Regulation of Level Verification System Valid
JJG 960-2001559 Add to Cart 4 days Verification Regulation of Level Verification System Obsolete

Similar standards

JJG 818   JJG 1114   JJF 1126   JJG 658   JJG 601   JJG 952   

Basic data

Standard ID: JJG 960-2012 (JJG960-2012)
Description (Translated English): Verification Regulation of Level Verification System
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A52
Classification of International Standard: 17.040
Word Count Estimation: 21,228
Older Standard (superseded by this standard): JJG 960-2001
Regulation (derived from): State Administration of Quality Supervision, Inspection and Quarantine Notice 2012 No. 63;
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine
Summary: This standard applies to all kinds of water level verification device initial verification, testing and use of follow-up inspection.

JJG 960-2012: Verification Regulation of Level Verification System

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Level Verification System National Metrological Verification Regulation of the People's Republic of China Level Verification Device 2012-04-17 release 2012-10-17 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Verification procedure of level tester stem Replacing JJG 960-2001 Unit. National Geometric Length Measurement Technical Committee The main drafting unit. China Institute of Metrology Henan Institute of Metrology Participate in the drafting unit. National photoelectric range finder testing center Zhejiang Institute of Metrology This procedure is commissioned by the National Geometry Length Metrology Technical Committee to explain The main drafters of this procedure. Shen Ni (China Institute of Metrology) Wang Heyan (China Institute of Metrology) Zhang Weidong (Henan Institute of Metrology) Participate in the drafters. Zhai Qingbin (National Photoelectric Rangefinder Testing Center) Jin Ting (Zhejiang Institute of Metrology)

table of Contents

Introduction (II) 1 Scope (1) 2 Overview (1) 3 Measurement performance requirements (1) 3.1 i angle micrometer indication error (1) 3.2 flat panel microcomputer indication error (1) 3.3 micro tilting table indication error (1) 3.4 Horizontal line compensator compensation error (1) 3.5 Horizontal Alignment Deviation (2) 3.6 multi-target deviation from the line error (2) 4 General technical requirements (2) 4.1 Appearance (2) 4.2 Interaction of components (2) 5 Measuring instruments (2) 5.1 Test conditions (2) 5.2 Verification Project (3) 5.3 Verification method (3) 5.4 Processing of test results (8) 5.5 Test cycle (8) Appendix A Calculation Form (9) Appendix B Automatic Anping Level Verification Device Horizontal Alignment Deviation Method APPENDIX C INSPECTION CERTIFICATE AND QUALIFICATION RESULTS Notice Page Format (12) Appendix D Level Level Verification Device Horizontal Alignment Deviation Measurement Results Uncertainty Evaluation Report Example (13)

Introduction

JJG 425 "level", JJG 8 "level scale" and JJG 960 "level test device" together constitute a large Measures for the measurement of the leveling of instruments. JJG 960-2012 "Level Verification Device" is written in JJF1002-2010 "National Metrological Verification Regulation The JJG 960-2001 "Level Verification Device" is revised on the basis of the rules and basis. versus JJG 960-2001 "level test device" compared to the editorial changes in the main technical changes are as follows. --- JJG 425-1994 "Level" and JB/T 7399-1994 "Parallel light pipe" are cited in the literature. Metrological performance requirements increase the i-angle micrometer indication error requirements, easy to improve the accuracy of the test; Cancel the parallel light pipe focal length and scale instructions error requirements. - The range of measurement of the level calibrator has been modified in the procedure. - the calibration method, the level of deviation for the automatic Anping and self-collimation of these two devices were done Introduction. - In Appendix B, an automatic ampere-type verification device is introduced for the use of the device itself. Number, only the level of the pedal to complete the test method. Level Verification Device

1 Scope

This procedure applies to all types of level test device of the first test, follow-up inspection and use of inspection.

2 Overview

Level measuring device is a kind of measuring device which can produce a horizontal line and can realize multi-target Mainly used for level calibration or calibration. According to the structure it can be divided into automatic Anping (see Figure 1) and self-collimation (see Figure 2), according to the level of deviation of its accuracy can be divided into 1, 2 and 3. Figure 1 Schematic diagram of automatic Anping level tester 1 - automatic Anping parallel light tube; 2 - was seized level Figure 2 from the collimation level level test device diagram 1 - parallel light tube; 2 - seized level

3 Measurement performance requirements

3.1 i angle micrometer indication error i angle micrometer indication error requirements in Table 1. 3.2 flat panel microcomputer indication error Flat plate microcomputer indication error requirements in Table 1. 3.3 micro tilting table indication error Micro tilting table indication error requirements see Table 1. 3.4 Horizontal alignment compensator compensation error Horizontal line compensator compensation error requirements in Table 1.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 960-2012_English be delivered?

Answer: Upon your order, we will start to translate JJG 960-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 960-2012_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 960-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 960-2012?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 960-2012 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.