JJG 919-2023 English PDFUS$419.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 919-2023: Verification Meters for pH Meters Status: Valid JJG 919: Historical versions
Basic dataStandard ID: JJG 919-2023 (JJG919-2023)Description (Translated English): Verification Meters for pH Meters Sector / Industry: Metrology & Measurement Industry Standard Word Count Estimation: 19,196 Date of Issue: 2023-03-15 Date of Implementation: 2023-09-15 Issuing agency(ies): State Administration for Market Regulation JJG 919-2023: Verification Meters for pH Meters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.National Metrology Verification Regulations of the People's Republic of China JJG 919-2023 pH meter calibrator Released on 2023-03-15 2023-09-15 Implementation Released by the State Administration for Market Regulation Verification Regulations for pH Meter Calibration Instrument Replace JJG 919-2008 Responsible Unit: National Technical Committee of Physical and Chemical Metrology Main drafting unit: China Institute of Metrology Inner Mongolia Autonomous Region Institute of Metrology and Testing Participating in the drafting unit: Shaanxi Institute of Metrology National Defense Science, Technology and Industry Commission Chemometrics Level 1 Station China Institute of Testing Technology Hunan Institute of Metrology This regulation entrusts the National Physical Chemometrics Technical Committee to be responsible for interpretation The main drafters of this regulation: Xiu Hongyu (National Institute of Metrology) Ning Quan (Inner Mongolia Autonomous Region Institute of Metrology and Testing) Participating drafters: He Xinyang (National Institute of Metrology, China) Yu Deshui (Shaanxi Institute of Metrology) Xun Qining (Level 1 Station of Chemometrics of the Commission of Science, Technology and Industry for National Defense) Zhang Yi (China Academy of Testing Technology) Peng Lihua (Hunan Institute of Metrology) Table of contentsIntroduction (Ⅱ) 1 Scope(1) 2 Overview(1) 3 Metrological performance requirements (1) 4 General technical requirements (1) 4:1 Appearance(1) 4:2 Power up and start up(2) 4:3 Identification(2) 5 Measuring Instrument Control(2) 5:1 Test conditions (2) 5:2 Measurement standards and supporting equipment (3) 5:3 Verification items (3) 5:4 Verification method (3) 5:5 Processing of verification results (6) 5:6 Verification cycle (6) Appendix A (0~100) ℃ k value (7) Appendix B Original Record Format of pH Meter Calibration Instrument Verification (8) Appendix C Format of the inner page of the verification certificate/test result notification (11)IntroductionThis procedure is based on JJF1001-2011 "General Metrology Terms and Definitions", JJF1002-2010 "National Metrology According to the provisions of "Rules for Writing Verification Procedures" and JJF1059:1-2012 "Assessment and Expression of Measurement Uncertainty" revised: During the writing process, JJF1587-2016 "Digital Multimeter Calibration Specification", JJF1638-2017 was referred to Performance indicators and calibration methods of digital multimeters and standard voltage sources in "Multifunctional Standard Source Calibration Specifications": Compared with JJG 919-2008, the main technical changes in this regulation are as follows except editorial modifications: ---Added pH meter calibrator to online pH meter, ion meter, automatic potentiometric titrator, etc: in "Overview" A description of the instrument for electrometric verification (see Chapter 2); --- Added the measurement performance requirements for "pH annual stability" in the "Measurement Performance Requirements", and improved The measurement performance index of the instrument "pH indication value stability" (see Table 1); ---In the "General Technical Requirements", the requirements for wireless connection control using Bluetooth/Wi-Fi or other methods have been added Requirements for split-type pH meter calibrator (see 4:2); ---Added the verification item and verification of "pH annual stability" in "verification items" and "verification methods" Method (see Table 3 and 5:4:4); --- Increased "inner page format of verification certificate/verification result notification" (see Appendix C): The previous releases of this regulation are as follows: ---JJG 919-2008; ---JJG 919-1996: Verification Regulations for pH Meter Calibration Instrument1 ScopeThis regulation is applicable to the initial verification, follow-up verification and in-use inspection of the pH meter calibrator:2 OverviewThe pH meter calibrator is a standard DC voltage signal output device, mainly used for calibrating pH (acidity) meters, Electrometer part of instruments such as ion meter and automatic potentiometric titrator: The pH meter calibration instrument (hereinafter referred to as the calibration instrument) is usually It consists of two parts, one is the standard DC voltage signal generation system of the calibrator, and the other is the high resistance device of the calibrator, which can also be It is called the electric meter input impedance detection system: The high resistance of the calibration instrument should be able to provide resistance values of 1GΩ and 3GΩ respectively: figure 1 A schematic diagram of the tester: (a) Calibration instrument with high resistance in series resistance (b) Calibration instrument with parallel resistance in high resistance Figure 1 Schematic diagram of the calibrating instrument3 Metering performance requirementsThe calibrator is divided into two levels: 0:003 and 0:0006: The 0:003 level calibration instrument is used for 0:01 level and below Electrometer verification of 0:01-level pH meters at all levels: The 0:0006 level calibration instrument is used for all levels of pH meters, ion meters, automatic electric meters Electrometric verification of titrators: The measurement performance requirements of the calibration instrument are listed in Table 1:4 General technical requirements4:1 Appearance The appearance of the calibrator is smooth and smooth, and the color is uniform: All function keys work normally, and all fasteners are not loose: attachment, output Outlets, power cords, etc: are complete: ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 919-2023_English be delivered?Answer: Upon your order, we will start to translate JJG 919-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 919-2023_English with my colleagues?Answer: Yes. The purchased PDF of JJG 919-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 919-2023?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 919-2023 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |