Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 657-2019 English PDF

US$489.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 657-2019: Breath Alcohol Analyzers
Status: Valid

JJG 657: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJG 657-2019489 Add to Cart 5 days Breath Alcohol Analyzers Valid
JJG 657-2006559 Add to Cart 3 days Verification Regulation of Detector for Alcoholic Quantity from Breathing-out Gas Obsolete
JJG 657-1990399 Add to Cart 3 days Verification Regulation of Detector for Alcoholic Quantity from Breathing -out Gas Obsolete

Similar standards

JJG 631   JJG 635   JJG 695   JJG 551   JJG 499   JJG 656   

Basic data

Standard ID: JJG 657-2019 (JJG657-2019)
Description (Translated English): Breath Alcohol Analyzers
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A61
Classification of International Standard: 17.020
Word Count Estimation: 21,217
Date of Issue: 2019
Date of Implementation: 2020-03-27
Issuing agency(ies): State Administration for Market Regulation

JJG 657-2019: Breath Alcohol Analyzers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Breath Alcohol Analyzers National Measurement Verification Regulations of the People's Republic of China Exhaled gas alcohol content detector 2019-09-27 release 2020-03-27 Implementation Issued by the State Administration of Market Supervision and Administration Exhaled gas alcohol content Verification Regulation of Detector Replace JJG 657-2006 Centralized unit. National Physical and Chemical Measurement Technical Committee Main drafting unit. China Academy of Metrology China Testing Technology Research Institute Guangdong Academy of Metrology Participated in the drafting unit. Zhejiang Institute of Metrology Institute of Transportation Management Science of the Ministry of Public Security Jiaside Technology (Shenzhen) Co., Ltd. Beijing Academy of Metrology and Testing Science This regulation is entrusted to the National Physical and Chemical Measurement Technical Committee for interpretation The main drafters of this regulation. Liu Yiling (Chinese Academy of Metrology) Founder (China Institute of Testing Technology) Houxiang Cui (Guangdong Institute of Metrology) Participating drafters. Lin Zhen (Zhejiang Institute of Metrology) Yu Chunjun (Institute of Transportation Management Science, Ministry of Public Security) Pan Weijiang (Jiaside Technology (Shenzhen) Co., Ltd.) Shen Zhengsheng (Beijing Institute of Metrology and Testing Science)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Overview (1) 4 Measurement performance requirements (1) 4.1 Indication error (1) 4.2 Repeatability (1) 4.3 Drift (1) 4.4 Anti-interference ability (1) 4.5 Residual effects of memory (2) 4.6 Expiratory resistance (2) 4.7 Measuring range, resolution and measurement unit conversion (2) 4.8 Minimum expiratory flow and minimum duration (2) 5 General technical requirements (2) 5.1 Appearance and structure (2) 5.2 Marks and logos (2) 5.3 Power-on inspection (2) 5.4 Retention and storage of results (2) 6 Control of measuring instruments (2) 6.1 Verification conditions (2) 6.2 Verification items (3) 6.3 Verification method (4) 6.4 Processing of verification results (6) 6.5 Verification period (6) Appendix A Requirements for Ethanol Standard Gas in Air and Precision Wine Detector (7) Appendix B. Method and requirements for traceability of ethanol gas concentration value produced by ethanol gas source (8) Appendix C Concentration of alcohol in exhaled breath (mole fraction μmol/mol) and alcohol in exhaled breath Conversion of mass concentration (mg/L) and blood alcohol concentration (mg/100mL) (11) Appendix D. Original Record Format of Exhaled Gas Alcohol Content Tester (12) Appendix E Format of the inner page of the certificate of verification/certification result (14)

Introduction

The main technical indicators of this regulation refer to GB/T 21254-2017 "Exhaled Gas Alcohol Content Detector" and Compared to.2006, the main changes except for editorial changes are as follows. --- The name of the regulation was changed to "exhaled gas alcohol content detector"; --- Modified the requirements of the "indication error", "repeatability", "anti-interference ability" and "expiratory resistance" (see 4.1, 4.2, 4.4, 4.6); --- Added "drift" "measurement range, resolution and measurement unit conversion" "exhalation minimum flow rate and shortest hold "Continuous time" index requirements (see 4.3, 4.7, 4.8); --- "Memory effect" was changed to "residual memory effect", and the indicator requirements were modified (see 4.5); --- The "result retention and storage time" item was adjusted to the "result result" in Chapter 5 "General Technical Requirements" Keep and store "(see 5.4) --- The verification item of "undervoltage alarm function" has been cancelled; --- Revised "Verification Environmental Conditions" "Standard Substances and Equipment for Verification" "List of Verification Items" (see 6.1.1, 6.1.2, Table 3); --- Modified the "indicating error", "repeatability", "anti-interference ability", "memory residual effect", "expiratory resistance" and Verification method of "Expiratory Time" (see 6.3.3, 6.3.4, 6.3.6, 6.3.7, 6.3.8, 6.3.9); --- Added "drift", "minimum expiratory flow and shortest duration", "measurement unit conversion", "measurement range" Verification method (see 6.3.5, 6.3.9, 6.3.10, 6.3.11); --- Amendment Appendix A "Requirements for Ethanol Standard Gas in Air and Precision Wine Detector" (see Appendix A); --- Added Appendix B "Method and Requirements for Traceability of Ethanol Gas Concentration Value Produced by Ethanol Gas Source" (See Appendix B); --- Added Appendix C "Exhaled alcohol concentration (mole fraction μmol/mol) and exhaled alcohol concentration Degree (mg/L) and conversion of blood alcohol concentration (mg/100mL) "(see Appendix C); --- Deleted Appendix D "Expiratory Alcohol Concentration and Blood Alcohol Concentration Comparison Table". The previous releases of this regulation are. --- JJG 657-2006; --- JJG 657-1990. Verification Regulations of Exhalation Gas Alcohol Content Detector

1 Scope

This regulation is applicable to the first verification, subsequent verification and in-use inspection of the exhaled gas alcohol content detector.

2 Reference documents

This regulation refers to the following documents. GB/T 21254-2017 Exhaled gas alcohol content detector For dated references, only the dated versions are applicable to this Regulation; for those without dates The latest version (including all amendments) is applicable to this regulation.

3 Overview

Exhaled breath alcohol content detector (hereinafter referred to as wine detector) is used to detect the alcohol content in human exhaled breath the amount. The wine detector consists of gas circuit, control circuit, alcohol sensor, breath detection system, sampling system and display printing system And other components. According to the measuring principle, the wine detector can be divided into battery type (ie electrochemical type), semiconductor type and infrared type.

4 Measurement performance requirements

4.1 Indication error The display error of the wine detector should meet the requirements of Table 1. Table 1 Indication error requirements First verification and subsequent verification (-0.040 ~ 0) mg/L Or relative error -10% ~ 0 Just one of them (-0.060 ~ 0) mg/L Or relative error -15% ~ 0 Just one of them 4.2 Repeatability The repeatability of the wine detector should meet the requirements of Table 2. Table 2 Repeatability requirements First verification Follow-up verification and inspection in use ≤1.7% ≤2.5% 4.3 Drift Zero drift. no more than 0.010mg/L. Indication drift. The indication drift at 0.4mg/L measurement point does not exceed 0.010mg/L. 4.4 Anti-interference ability
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 657-2019_English be delivered?

Answer: Upon your order, we will start to translate JJG 657-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 657-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 657-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 657-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 657-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.