JJG 593-2016 English PDFUS$529.00 · In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 593-2016: Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and γ Radiation Status: Valid JJG 593: Historical versions
Basic dataStandard ID: JJG 593-2016 (JJG593-2016)Description (Translated English): Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and �� Radiation Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A58 Word Count Estimation: 23,248 Date of Issue: 2016-11-30 Date of Implementation: 2017-05-30 Older Standard (superseded by this standard): JJG 593-2006 Regulation (derived from): State Administration of Quality Supervision, Inspection and Quarantine Notice No.119 of 2016 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine JJG 593-2016: Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and γ Radiation---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Thermoluminescence Dosimetry Systems Used in Personal and Environmental Monitoring for X and γ Radiation National Metrological Verification Regulation of the People's Republic of China Individual and environmental monitoring with X, gamma radiation thermoluminescence dose measuring system 2016-11-30 release 2017-05-30 implementation State Administration of Quality Supervision, Inspection and Quarantine issued Personal and environmental monitoring with X, gamma radiation Verification procedure of thermoluminescence dose measurement system VerificationRegulation ofThermoluminescence Replacing JJG 593-2006 Unit. National Diameter Radiation Metrology Technical Committee Drafting unit. China Testing Technology Research Institute Shanghai Institute of Metrology and Testing Technology This procedure is entrusted to the National Council on Ionizing Radiation Metrology The main drafters of this procedure. Liu Zhihong (China Testing Technology Research Institute) Chen Jianxin (Shanghai Institute of Metrology and Testing Technology) Li Jing (China Testing Technology Research Institute) Participate in the drafters. But Yu Juan (China Test Technology Research Institute) Yu Bing (China Institute of Testing Technology) table of ContentsIntroduction (II) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Terms (1) 3.2 Units of measurement (2) 4 Overview (2) 5 Metrological performance requirements (3) 6 General technical requirements (4) 6.1 Dosimeter (4) 6.2 Reader (4) 7 Metering device control (4) 7.1 Test conditions (4) 7.2 Verification Project (5) 7.3 Verification method (5) 7.4 Processing of test result (8) 7.5 Test cycle (8) Appendix A Recommended Verification Record Format (9) Appendix B Verification Certificate Page Format (10) Appendix C Results Notice Page Format (11) Appendix D Conversion coefficient of air to kinetic energy to dose equivalent (12) Appendix EX Characteristics and Conditions of Reference Radiation (14) Appendix F Confidence Interval (16)IntroductionThe procedures to GB/T 10264-2014 "personal and environmental monitoring with thermoluminescence dose measurement system" as the basis, According to JJF1002-2010 "national measurement procedures for the preparation of rules" requirements, the JJG 593-2006 repair Set, compared with JJG 593-2006 version, in addition to editorial changes, the main changes are as follows. --- The name of the test procedure is defined by "Personal and Environmental Monitoring with X, γ Radiation Thermoluminescence Dose Measurement (Device) "Changed to" personal and environmental monitoring with X, γ radiation thermoluminescence dose measurement system "; --- "test project" added a "coefficient of variation" and its corresponding content; The previous versions of this order are released as follows. --- JJG 593-2006; JJG 593-1989 and JJG 698-1990. Test procedures for X and γ radiation thermoluminescence dosimetry systems for personal and environmental monitoring1 ScopeThis procedure applies to measuring the dose range of 0.01mSv ~ 10Sv, the energy range of 30keV ~ 1.5MeV (10) and the surrounding dose equivalent H * (10), and the energy range is 8keV ~ 250keV personal dose equivalent Hp (0.07) thermoluminescence dose measurement system for the first time, follow-up Check and check in use. This procedure does not apply to devices equipped with an extremist dosimeter for personal monitoring and does not apply to pulse X, gamma radiation Radiation, beta radiation, neutron radiation and cosmic ray radiation devices.2 reference fileThis procedure refers to the following documents. Thermoluminescence dosimetry systems for personal and environmental monitoring GB/T 12162.1 X and γ reference radios for calibrating dosimeters and dosimetry instruments and determining their energy response Part 1. Radiation characteristics and methods of production GB/T 12162.2 X and γ reference radios for calibrating dosimeters and dosimetry instruments and determining their energy response Part 2. Radiation protection with energy ranges from 8 keV to 1.3 MeV and 4 MeV to 9 MeV Radiation dose determination GB/T 12162.3 X and γ reference radiation for calibrating dosimeters and dosimetry instruments and determining their energy response Part 3. Calibration of place dosimeters and personal dosimeters and determination of their energy response and angular response IEC 62387-1..2007 Radiation protection instruments Passive integral dose measurement for environmental and personal monitoring System - Part 1. General characteristics and performance requirements (Radiationprotectioninstrumentation - Passive integratingdosimetrysystemsforenvironmentalandpersonalmonitoring-Part 1. Gen- eralcharacteristics andperformancerequirements) For dated references, only the dated edition applies to this rule, and references that are not dated , The latest version (including all amendments) applies to this procedure.3 terms and units of measurement3.1 terminology 3.1.1 Thermoluminescence (TL) A substance that exhibits a light that emits light when irradiated with ionizing radiation or ultraviolet rays. 3.1.2 thermoluminescent detector (referred to as detector) thermoluminescent (TL) detector A certain amount of thermoluminescent material, or the material and other non-luminescent material by a certain weight ratio of the composition of a definite Volume, shape or size of the mixture, the detector is absorbed by the radiation and store part of the energy of the radiation, in the measurement process This part of the energy is released in the form of light when the detector is heated. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 593-2016_English be delivered?Answer: Upon your order, we will start to translate JJG 593-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 593-2016_English with my colleagues?Answer: Yes. The purchased PDF of JJG 593-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 593-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 593-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |