JJG 588-2018 English PDFUS$509.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 588-2018: Impulse Peak Voltmeters Status: Valid JJG 588: Historical versions
Basic dataStandard ID: JJG 588-2018 (JJG588-2018)Description (Translated English): Impulse Peak Voltmeters Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A55 Word Count Estimation: 22,254 Date of Issue: 2018-02-27 Date of Implementation: 2018-08-27 Older Standard (superseded by this standard): JJG 588-1996 Regulation (derived from): AQSIQ Announcement No. 26 of 2018 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine JJG 588-2018: Impulse Peak Voltmeters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.(Impact peak voltage meter verification procedure) National Metrology Verification Regulations of the People's Republic Impact peak voltmeter Published on.2018-02-27 2018-08-27 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Impact peak voltmeter Verification procedure Replace JJG 588-1996 Focal Point. National Electromagnetic Measurement Technical Committee High Voltage Measurement Subcommittee Main drafting unit. National High Voltage Metering Station State Grid Hubei Electric Power Company Electric Power Research Institute Participated in the drafting unit. State Grid Jiangsu Electric Power Company Electric Power Research Institute State Grid Shanghai Electric Power Company Electric Power Research Institute State Grid Heilongjiang Electric Power Company Electric Power Research Institute This regulation entrusts the National Electromagnetic Measurement Technical Committee High Voltage Measurement Subcommittee to explain The main drafters of this procedure. Liu Shaobo (National High Voltage Metering Station) Long Zhaozhi (National High Voltage Metering Station) Wang Tao (State Grid Hubei Electric Power Company Electric Power Research Institute) Participate in the drafters. Zhou Zhicheng (State Grid Jiangsu Electric Power Company Electric Power Research Institute) Jin Wei (State Grid Shanghai Electric Power Company Electric Power Research Institute) Gongyou (State Grid Heilongjiang Electric Power Company Electric Power Research Institute) table of ContentsIntroduction (II) 1 Scope (1) 2 References (1) 3 terms (1) 3.1 Impact Peak Voltmeter (1) 4 Overview (1) 5 Metrological performance requirements (1) 5.1 Basic error (1) 5.2 Accuracy level (2) 5.3 Repeatability (2) 5.4 Short-term stability (2) 6 General technical requirements (2) 6.1 Appearance (2) 6.2 Input impedance (2) 6.3 Insulation resistance (2) 6.4 Power frequency withstand voltage (2) 7 measuring instrument control (2) 7.1 Verification conditions (2) 7.2 Verification items and verification methods (3) 7.3 Processing of verification results (5) 7.4 Verification cycle (5) Appendix A Verifying the Original Record Format (6) Appendix B Format of the Certificate/Verification Result Notice (Page 2) (11) Appendix C Verification Certificate/Verification Result Notice Verification Result Format (Page 3) (12)IntroductionThis regulation is based on JJF1001-2011 "General Measurement Terms and Definitions", JJF1002-2010 "National Measurement The rules for the preparation of verification procedures are formulated. This regulation amends JJG 588-1996, compared with JJG 588-1996, except for editorial changes. The technical changes are as follows. --- Modify the representation of the basic error of "measurement performance" (see 5.1); --- "Measuring performance" increases the need for repeatability (see 5.3); --- Increase the standard wave source time parameters (see 7.1.4); --- Removed the content of the original procedure using the comparative method to verify the basic error; ---Modified the requirements of the "basic error" verification voltage point and the number of measurements (see 7.2.2.4); --- Removed the original procedure "basic error" plus test requirements. The previous versions of this procedure were released as follows. ---JJG 588-1996. Impact peak voltmeter verification procedure1 ScopeThis procedure is applicable to the first verification of the digital impact peak voltmeter with a measurement range of ±(100~1600)V. Subsequent verification and in-use inspection.2 reference filesThis procedure refers to the following documents. GB/T 16896.1 High voltage impulse measuring instruments and software Part 1 requirements for instruments GB/T 16927.1 High Voltage Test Technique Part 1. General Definitions and Test Requirements For dated references, only the dated version applies to this Code; any undated quotation The latest version (including all amendments) applies to this procedure.3 termsThe terms and definitions established in GB/T 16896.1 and GB/T 16927.1 apply to this standard. 3.1 Impact peak voltmeter impulseIvoltometer An instrument capable of measuring the peak value of the surge voltage. There should be no short-term overshoot or short time near the peak of the surge voltage. High frequency oscillation. [GB/T 16896.1-20053.1.3]4 OverviewThe digital impulse peak voltmeter (hereinafter referred to as the peak table) is an instrument for measuring the peak value of the surge voltage. when using it, The peak meter is connected to the secondary voltage output of the surge voltage divider through a transmission cable to measure the voltage of the surge voltage divider. Output voltage peak. By inputting the voltage division ratio of the surge voltage divider on the peak surface plate, the peak table display unit can The primary voltage peak applied to the surge voltage divider is directly displayed. The peak table is generally composed of a secondary attenuator, A/D The acquisition conversion unit and the display device are composed.5 Metrological performance requirements5.1 Basic error The maximum allowable error of the peak voltage of the peak meter is as shown in equation (1). Δ=±(a%Ux b%Um) (1) In the formula. Δ---maximum allowable error, V or kV; a---the error coefficient related to the reading value; b---the error coefficient related to the range; Ux---the reading value of the peak table to be inspected, V or kV; ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 588-2018_English be delivered?Answer: Upon your order, we will start to translate JJG 588-2018_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 588-2018_English with my colleagues?Answer: Yes. The purchased PDF of JJG 588-2018_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 588-2018?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 588-2018 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |