JJG 536-2015 English PDFUS$739.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 536-2015: Verification Regulation of Polarimeter and Polarimetric Saccharimeters Status: Valid JJG 536: Historical versions
Basic dataStandard ID: JJG 536-2015 (JJG536-2015)Description (Translated English): Verification Regulation of Polarimeter and Polarimetric Saccharimeters Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A61 Classification of International Standard: 17.020 Word Count Estimation: 32,375 Date of Issue: 2015-01-30 Date of Implementation: 2015-07-30 Older Standard (superseded by this standard): JJG 536-1998 Regulation (derived from): The State Administration of Quality Supervision, Inspection and Quarantine Announcement 2015 No. 19 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This Standard applies to polarimeter, optical glucose meter's initial verification, subsequent verification and the use of checks. JJG 536-2015: Verification Regulation of Polarimeter and Polarimetric Saccharimeters---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Regulation of Polarimeter and Polarimetric Saccharimeters State verification procedures People's Republic of China Polarimeter and optical glucose meter Issued on. 2015-01-30 2015-07-30 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Polarimeter optical glucose meter and test procedures Replacing JJG 536-1998 Focal point. the National Technical Committee stoichiometric physical Main drafting unit. Heilongjiang Provincial Academy of verification test Participated in the drafting unit. Shanghai Instrument Instrument Co., Ltd. Mai This procedure commissioned the National Technical Committee of the stoichiometric physics responsible for the interpretation The main drafters of this procedure. Ding Haiming (Heilongjiang Provincial Academy of verification test) Drafters participate. Shao Yi Fang (Shanghai Instrument Instrument Co., Ltd. Mai) table of ContentsIntroduction (Ⅲ) 1 Scope (1) 2 Terms and definitions (1) Optically 2.1 (1) 2.2 optical rotation (1) 3 Overview (1) 4 metering performance requirements (3) 4.1 visual polarimeter and visual optical glucose meter (3) 4.2 automatic and automatic polarimeter optical glucose meter (4) 5 General technical requirements (4) 5.1 visual polarimeter and visual optical glucose meter (4) 5.2 automatic and automatic polarimeter optical glucose meter (4) 6 Control of measuring instruments (5) 6.1 Verification condition (5) 6.2 test items and test methods (6) 6.3 Verification Results Processing (8) 6.4 test cycle (9) Appendix A ICUMSA International Brix scale (10) Appendix B visual polarimeter and visual optical glucose meter test record format (11) Appendix C automatic and automatic polarimeter optical glucose meter test recording format (16) Appendix D calibration certificate/test results in the notice page format (22)IntroductionThe procedure according to JJF1002-2010 "national verification procedures to write rules" were written while using ICUMSASpecificationandStandardSPS-1 (2009) (2009 Nian ICUMSA standards and SPS-1 standard Quasi) The international Brix scale. Compared with JJG 536-1998, in addition to editorial changes, the major technological change as follows. --- Increased contents Introduction; --- Increasing the content of terms and definitions (see 2); --- The "optical glucose meter" in English, translated by Saccharimeter modify PolarimetricSaccharim- eters; --- Added "instrument indication error" in the near-infrared light source temperature correction formula (see 6.2.3.2); --- Added "Auto rotation glucose meter low permeability indication error and repeatability should not exceed the level corresponding to begging. "Content (see 4.2.4); --- Revised Brix scale "international Brix scale" in the near-infrared light source (see Appendix A); --- Canceled a procedure for testing the pipe requirements; --- Cancel the original statutes "verification certificate" appendix in Appendix D "test certificate/test results in the notice Page Format Shape "instead. The previous versions of the release JJG 536 case. --- JJG 536-1988 visual polarimeter pilot test procedures; --- JJG 675-1990 automatic and automatic polarimeter optical glucose meter test procedures; --- JJG 536-1998 polarimeter optical glucose meter and test procedures. Polarimeter optical glucose meter and test procedures1 ScopeThe order applies to polarimeter, optical glucose meter's initial verification, use and subsequent verification check.2 Terms and definitionsThe following terms and definitions apply to this procedure. 2.1 Optical rotatorypolarization When linearly polarized light propagation in the medium, the plane of polarization rotation phenomenon. 2.2 Optical rotation specificrotation Also known as rotation rate. Characterization of the amount of the optically active substance of optical capacity size. It uses linearly polarized light through a unit thickness spin After its plane of polarization of light materials to represent the angle of rotation.3 OverviewPolarimeter is an instrument measuring the optical rotation material, according to the instrument work is divided into visual and automatic polarimeter polarimeter Categories. Optical glucose meter Brix scale is based on the international scale polarimeter, according to work is divided into visual instrument optically sugar Meter and automatic optical glucose meter categories. Polarimeter and optical glucose meter (hereinafter referred to as the instrument) works. from the light source, a condenser lens, a diaphragm, filter Rays and other produce monochromatic parallel beam through the polarizer natural light into polarized light, and through the test tube, the analyzer It is hitting the eyepiece (visual instrument) or photodetector (automatic device). When the instrument is in the optical zero point, and the polarizer Vibration analyzer plane perpendicular to each other, substantially opaque, dark eyepiece field or photodetector output signal of the most small. When the test tube into the optically active substance characteristic, optical properties of a material having a polarized light rotated by a certain angle, The incident light and vibration analyzer is not perpendicular to the surface, resulting in a certain intensity of the transmitted light, bright field of view of the eyepiece field of view or The photodetector output signal becomes large, and then turn the dial is connected to the analyzer by manual or servo motor (or polarizer , A quartz wedge), re-meet the basic opaque optical balance, which can be read or instrument or exhibit optical rotation Brix value is shown. Figure 1 is a visual and visual polarimeter optical glucose meter optical structure. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 536-2015_English be delivered?Answer: Upon your order, we will start to translate JJG 536-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 536-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJG 536-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 536-2015?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 536-2015 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |