JJG 505-2004 English PDFUS$629.00 ยท In stock
Delivery: <= 5 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 505-2004: Verification Regulation of D.C.Comparator potentiometers Status: Valid JJG 505: Historical versions
Basic dataStandard ID: JJG 505-2004 (JJG505-2004)Description (Translated English): Verification Regulation of D.C.Comparator potentiometers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A55 Classification of International Standard: 17.220 Word Count Estimation: 24,249 Date of Issue: 2004-03-02 Date of Implementation: 2004-09-02 Older Standard (superseded by this standard): JJG 505-1987 Quoted Standard: GB 3927-1983; JB/T 8611-1997 Regulation (derived from): Administration of Quality Supervision, Inspection and Quarantine No. 24 of 2004 Issuing agency(ies): State Administration of Quality Supervision, Inspection and Quarantine Summary: Potentiometer part of this standard applies to magnetic potential self-balancing potentiometer DC Comparator and versatility DC comparator (hereinafter referred to compare ceremony potentiometer or potential difference) in the first test, test and use the subsequent test. JJG 505-2004: Verification Regulation of D.C.Comparator potentiometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Regulation of DCComparator potentiometers National Metrology Verification Regulations of the People's Republic DC comparison ceremony potentiometer Released on.2004-03-02 2004-09-02 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued DC comparison ceremony potentiometer Verification procedure DCComp Replacing JJG 505-1987 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 02,.2004, and Implemented on September 2,.2004. Focal Point. National Electromagnetic Measurement Technical Committee Drafting unit. Heilongjiang Provincial Metrology Testing and Testing Institute This procedure entrusts the National Electromagnetic Measurement Technical Committee to explain The main drafters of this procedure. Wang Yong (Heilongjiang Metrological Testing and Testing Institute) Participate in the drafters. Yang Wei (Heilongjiang Metrological Testing and Testing Institute) table of Contents1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Metrological performance requirements (2) 4.1 Accuracy level (2) 4.2 Basic error (2) 4.3 Potential drift (3) 4.4 Low frequency noise (3) 4.5 Tracking Error (3) 4.6 Nonlinear error (3) 4.7 Primary current constancy (3) 4.8 Current Regulation Disk Indicators (3) 4.9 Ripple Voltage (3) 4.10 Primary Maximum Output Voltage (3) 4.11 galvanometer and its circuit switch indicators (3) 5 General technical requirements (3) 5.1 Appearance structure (3) 5.2 Insulation resistance (3) 5.3 Dielectric strength (3) 6 measuring instrument control (4) 6.1 Verification conditions (4) 6.2 Verification project (4) 6.3 Verification method (5) 6.4 Processing of verification results (11) 6.5 Verification cycle (12) Appendix A Linearity Self-Test Form (13) Appendix B Derivation of Linearity Self-Test Calculation Formula (17) Appendix C Format of verification certificate and verification result page (19) DC comparison ceremony potentiometer verification procedure1 ScopeThis procedure is applicable to the potential difference between the DC comparison ritual potentiometer and the multi-function DC comparator for automatic balance of magnetic potential. The first verification, subsequent verification and in-use inspection of the meter part (hereinafter referred to as comparison ceremony potentiometer or potentiometer) Test.2 CitationsGB 3927-1983 "DC potential difference meter" JB/T 8611-1997 "DC Potentiometer" When using this procedure, care should be taken to use the current valid version of the above cited documents.3 OverviewThe comparison ritual potentiometer is adjusted by changing the number of turns of the measuring winding in the auto-balanced DC current comparator. Determining the DC current on the constant measurement resistor to obtain a constant resistance variable current differential of the continuously variable compensation voltage meter. The principle circuit is shown in Figure 1. The working principle is. primary variable measuring winding and secondary fine-tuning fixed winding Self-flowing constant DC current and variable DC current, they generate opposite magnetic potentials on the core, and the magnetic potential difference is Detecting the winding detection and adjusting the secondary current generated by the driven (servo) power supply through the differential closed-loop regulation system to make the magnetic potential Figure 1 Comparison of the principle circuit of the ritual potentiometer W1---primary variable winding, ie measuring disc; W2---secondary fixed winding with fine adjustment Automatic balance. After the potential difference meter operating current is set with a standard battery, the primary current and the secondary winding turns off. It is all constant, because the secondary current is proportional to the number of primary turns, so the compensation voltage on the measuring resistor in the secondary loop is equal. The ratio of the primary turns in the measurement to the primary turns in the timing is multiplied by the electromotive force of the standard battery. This is the turns ratio. The working principle of the comparison ritual potentiometer instead of the resistance ratio. The formula is derived as follows. a. Set the working current Connect the standard battery to both ends of the measuring resistor RAC, and measure the value of the measuring disc W1 to the standard battery after temperature correction. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 505-2004_English be delivered?Answer: Upon your order, we will start to translate JJG 505-2004_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 505-2004_English with my colleagues?Answer: Yes. The purchased PDF of JJG 505-2004_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 505-2004?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 505-2004 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |