JJG 427-2004 English PDFUS$369.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 427-2004: Verification Regulation of Micrometers with Gauge Status: Valid JJG 427: Historical versions
Basic dataStandard ID: JJG 427-2004 (JJG427-2004)Description (Translated English): Verification Regulation of Micrometers with Gauge Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A52 Classification of International Standard: 17.040 Word Count Estimation: 14,188 Date of Issue: 2004-03-02 Date of Implementation: 2004-09-02 Older Standard (superseded by this standard): JJG 427-1986 Quoted Standard: JJF 1001-1998; JJF 1059-1999; GB/T 1216-1985; JJF 1094-2002; JJG 39-1990 Regulation (derived from): Administration of Quality Supervision, Inspection and Quarantine of 2004 No. 24 Issuing agency(ies): State Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to the measurement limit to 100mm, with indexing table is 0. 001mm micrometer initial verification, testing and use of follow-up inspection. JJG 427-2004: Verification Regulation of Micrometers with Gauge---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Regulation of Micrometers with Gauge National Metrology Verification Regulations of the People's Republic Micrometer with table Released on.2004-03-02 2004-09-02 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Meter micrometer verification procedure Replacing JJG 427-1986 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on March 02,.2004, and Implemented on September 2,.2004. Focal Point. National Geometric Quantity Engineering Measurement Technology Committee Drafting unit. Heilongjiang Provincial Metrology Testing and Testing Institute Harbin Metrology Testing and Testing Institute Harbin Electric Machinery Co., Ltd. Jilin Institute of Metrology This regulation entrusts the National Geometric Quantity Engineering Parametric Measurement Technical Committee to explain The main drafters of this procedure. Ma Wei (Heilongjiang Metrological Testing and Testing Institute) Wang Li (Harbin Metrology Testing Institute) Jinyun Library (Harbin Electric Machinery Co., Ltd.) Ma Zhonghuan (Jilin Institute of Metrology) Participate in the drafters. Zhang Yundong (Harbin Metrology Testing Institute) table of Contents1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Metrology performance requirements (1) 4.1 scribe line width and width difference (1) 4.2 The relative position of the end face of the tapered cone and the millimeter line on the fixed sleeve (2) 4.3 Distance from the tapered edge of the differential cone to the scribed plane of the fixed sleeve (2) 4.4 Flatness and parallelism of two measuring surfaces with table micrometers (2) 4.5 Comparator with meter micrometer (2) 4.6 Force measurement and force measurement with meter micrometer (2) 4.7 indication error with table micrometer (2) 4.8 Repeatability with a table micrometer (2) 5 General technical requirements (2) 5.1 Appearance (2) 5.2 Interaction of various parts (2) 6 measuring instrument control (3) 6.1 Verification project (3) 6.2 Verification conditions (3) 6.3 Verification method (3) 6.4 Verification result processing (5) 6.5 verification period (5) Appendix A Evaluation of Uncertainty in Measurement Errors with Meter Micrometers (6) Appendix B Format of verification certificate and verification result page (9) Meter micrometer verification procedure1 ScopeThis procedure is applicable to the first verification of a metered micrometer with an upper limit of 100 mm and a graduation value of 0.001 mm. Subsequent verification and in-use inspection.2 CitationsThis procedure refers to the following documents. JJF1001-1998 General measurement terms and definitions JJF1059-1999 Measurement Uncertainty Evaluation and Representation GB/T 1216-1985 outer diameter micrometer JJF1094-2002 Measuring instrument characteristic evaluation JJG 39-1990 Mechanical comparator calibration procedures When using this procedure, care should be taken to use the current valid version of the above cited documents.3 OverviewThe meter with a micrometer (see Figure 1) is a mechanical comparator (hereinafter referred to as the comparator), the ruler and the micrometer. A micrometer that is divided into groups. It is mainly used for comparative measurement of external dimensions. The measuring range with the micrometer is generally divided into (0~25)mm, (25~50)mm, (50~75)mm and (75~100) mm four. The comparator scale value is 0.001mm, and the indication range is generally ±0.03mm and ±0.05mm. Two. Figure 1 with a table micrometer 1-scale frame; 2-anvil; 3-micrometer screw; 4-locking device; 5-fixed sleeve; 6-microtube; 7-insulation device; 8-comparator4 Metrological performance requirements4.1 scribe line width and width difference The width of the longitudinal line on the fixed sleeve and the score line on the differential cylinder are (0.15~0.20) mm, and the difference between the line widths is not exceeded. Over 0.03mm. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 427-2004_English be delivered?Answer: Upon your order, we will start to translate JJG 427-2004_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 427-2004_English with my colleagues?Answer: Yes. The purchased PDF of JJG 427-2004_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 427-2004?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 427-2004 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |