JJG 314-2010 English PDFUS$489.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 314-2010: Verification Regulation of Instrument Voltage Transformers Status: Valid JJG 314: Historical versions
Basic dataStandard ID: JJG 314-2010 (JJG314-2010)Description (Translated English): Verification Regulation of Instrument Voltage Transformers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A55 Classification of International Standard: 17.220 Word Count Estimation: 21,283 Date of Issue: 2010-11-05 Date of Implementation: 2011-05-05 Older Standard (superseded by this standard): JJG 314-1994 Quoted Standard: JB/T 5473-1991; GB/T 16927.1-1997 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to rated frequency 50HZ (or 60HZ) of 0. 001 ~ 0. 5 for measuring voltage transformer initial verification, testing and use of follow-up inspection. JJG 314-2010: Verification Regulation of Instrument Voltage Transformers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Regulation of Instrument Voltage Transformers State verification procedures People's Republic of China Measuring voltage transformer Issued on. 2010-11-05 2011-05-05 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Measuring voltage transformer test procedures Voltag eTransformers Replacing JJG 314-1994 The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on November 5, 2010, and from From May 5, 2011 implemented. Focal point. the National Technical Committee on Electromagnetic measurement The main drafting units. the national high voltage metering station Participated in the drafting. Guangdong Electric Power Research Institute Jiangsu Provincial Power Company Henan Institute of Metrology Hunan Electric Power Test & Research Institute The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic The main drafters of this procedure. Wang Qin (the national high voltage metering station) Man Ray (the national high voltage metering station) Wangle Ren (the national high voltage metering station) Drafters participate. Zhou Shangli (Guangdong Electric Power Research Institute) Huang Qifeng (Jiangsu Provincial Power Company) STAFF time (Henan Institute of Metrology) Zhou Weihua (Hunan Electric Power Test & Research Institute) table of Contents1 Scope (1) 2. Referenced Documents (1) 3 metering performance requirements (1) 3.1 basic error (1) Lift variation 3.2 (2) 3.3 Stability (2) 4 General Requirements (2) 4.1 Appearance (2) 4.2 insulation (2) 5 control of measuring instruments (2) 5.1 verification Conditions (2) 5.2 Verification Project (3) 5.3 Verification Methods (4) 5.4 Verification Results Processing (9) 5.5 test cycle (10) Appendix A test record format (11) Appendix B test certificate page format (13) Appendix C test results in the notice page format (15) Measuring voltage transformer test procedures1 ScopeMeasuring 0.001 ~ 0.5 of this Regulation applies to the rated frequency of 50Hz (or 60Hz) with a voltage mutual Sensor (hereinafter referred to as voltage transformer) the initial verification, subsequent verification and in-service inspection.2 CitationsThe regulations cited the following criteria. JB/T 5473-1991 Instrument voltage transformers GB/T 16927.1-1997 high voltage test techniques Part 1. General test requirements When using this procedure, it should pay attention to using the currently valid version of the referenced standard.3 metering performance requirements3.1 basic error When the ambient temperature is 0 ℃ ~ 40 ℃, relative humidity less than 80%, ambient electromagnetic interference and mechanical vibration can be ignored Murillo, measuring voltage transformer rated frequency, rated power factor and load secondary rated secondary load When any value between 25% to 100% of each accuracy level of error should not exceed the limits in Table 1. The actual error curve voltage transformer should not exceed the scope of Table 1 lists a line formed by connecting the error limits. Table 1 Measuring voltage transformer error limits Accuracy level Error ratio (±) Magnification Factor Rated voltage percentile 205080100120 Phase error (±) Magnification Factor Rated voltage percentile 205080100120 0.5 0.2 0.1 0.05 0.02 0.01 - - 0.5 0.5 0.5 0.4 0.3 0.2 0.2 0.2 0.20 0.15 0.10 0.10 0.10 0.100 0.075 0.050 0.050 0.050 0.040 0.030 0.020 0.020 0.020 0.020 0.015 0.010 0.010 0.010 ( ') - - 20 20 20 10.0 7.5 5.0 5.0 5.0 4.0 3.0 2.0 2.0 2.0 1.2 0.9 0.6 0.6 0.6 0.60 0.45 0.30 0.30 0.30 0.005 0.002 0.001 × 10-6 10075505050 4030202020 × 10-6 (Rad) 10075505050 4030202020 Note. The rated secondary load 0.2VA or less, the lower limit of the load by 0VA assessment. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 314-2010_English be delivered?Answer: Upon your order, we will start to translate JJG 314-2010_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 314-2010_English with my colleagues?Answer: Yes. The purchased PDF of JJG 314-2010_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 314-2010?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 314-2010 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |