JJG 22-2014 English PDFUS$529.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 22-2014: Verification Regulation of Internal Micrometers Status: Valid JJG 22: Historical versions
Basic dataStandard ID: JJG 22-2014 (JJG22-2014)Description (Translated English): Verification Regulation of Internal Micrometers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A52 Classification of International Standard: 17.040 Word Count Estimation: 23,294 Date of Issue: 11/17/2014 Date of Implementation: 5/17/2015 Older Standard (superseded by this standard): JJG 22-2003 Quoted Standard: GB/T 8177; GB/T 22093-2008 Regulation (derived from): The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 No. 125 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This Standard applies to: a value of 0.01 mm or indexing resolution of 0.001 mm, micrometer indication range 13 mm, 25 mm, 50 mm, measuring not more than the upper limit of the inner diameter of 6 000mm extension bar micrometer, a single shot point inside JJG 22-2014: Verification Regulation of Internal Micrometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Regulation of Internal Micrometers State verification procedures People's Republic of China Inside micrometer Issued on. 2014-11-17 2015-05-17 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Micrometer diameter test procedures Replacing JJG 22-2003 NFP. National Engineering Geometrical Parameters Measurement Technology Committee Main drafting unit. Heilongjiang Provincial Academy of verification test Harbin Measuring & Cutting Tool Group Co., Ltd. Mudanjiang City of Quality and Technical Supervision and Testing Center Participated in the drafting. Suzhou McCrone measurement technology Co., Ltd. Liaoning Provincial Institute of Metrology This procedure works commissioned by the National geometric parameter measurement technology committee responsible for the interpretation The main drafters of this procedure. Han Zhengyang (Heilongjiang Provincial Academy of verification test) Zhang Haibo (Heilongjiang Provincial Academy of verification test) Dong Yuwen (Harbin Measuring & Cutting Tool Group Co., Ltd.) In Wenlong (Mudanjiang City of Quality and Technical Supervision and Inspection Center) Drafters participate. Huang Xiaobin (Suzhou McCrone measurement technology Co., Ltd.) Liu Ying (Heilongjiang Academy of verification test) Na Liu (Liaoning Provincial Institute of Metrology) table of ContentsIntroduction (Ⅱ) 1 Scope (1) 2. References (1) 3 Overview (1) 4 metering performance requirements (2) 4.1 radius of curvature of the probe measuring surface (2) 4.2 measuring surface roughness of the surface (2) 4.3 groove width and width difference (2) 4.4 differential cylinder tapered edges fixed to the casing from the surface of the engraved lines (2) The relative positions of end faces of the differential cylinder 4.5 mm tapered sleeve is fixed in the groove (2) Shows the change (2) value of 4.6 micrometer locking device locking and release time 4.7 Value drift (2) 4.8 digital value Consistency of Readings and differential cylinder (2) 4.9 Indication error (2) 4.10 rigid cause a change in the length dimension (3) 4.11 proofreading caliper indication error and two parallel face (3) 5 General technical requirements (4) 5.1 Appearance (4) 5.2 Interaction of each part (4) 6 Control of measuring instruments (4) 6.1 Verification condition (4) 6.2 test items and test equipment (4) 6.3 Verification Methods (5) 6.4 test result processing (8) 6.5 test cycle (8) Appendix A micrometer head and the ground pole combinations Examples (9) Appendix B inside micrometer indication error of measurement uncertainty evaluation (10) Appendix C measuring machine with laser interferometer measurement indication error description (13) Appendix D calibration certificate/test results in the notice page and format (14)IntroductionJJF1002-2010 "national verification procedures write rules", JJF1001-2011 "common terminology and measurement Definitions ", JJF1059.1-2012" Evaluation and Expression of Uncertainty in Measurement ", JJG 22-2003" inside micrometer inspection Setting rules "(hereinafter referred to as the original regulations) constitute the basis of technical regulations of the series metering regulations revision. This procedure is JJG 22-2003 amendments. Compared with JJG 22-2003, in addition to editorial changes outside the main technical Surgery changes are as follows. --- According to GB/T 22093-2008 "electronic digital micrometer diameter" and GB/T 8177-2004 "points Inside micrometer "newly added electronic digital display device" consistent value drift "and" digital value and differential cylinder readings Of "verification project, while increasing technical requirements and test methods corresponding to the project. --- According to GB/T 8177-2004 "points inside micrometer" Edit "groove width and width difference" Without Fixed tube diameter with the same requirements. --- Edit "change indication error indication micrometer head and locking device locking and release time" is shown in the micrometer head Error requirements. --- Edit "micrometer head and the ground pole combination of size" to "indication error", do not use the checking of inspection. --- According to GB/T 8177-2004 "points inside micrometer" modified "show error" and "rigid lead From the length of the change in size, "the technical requirements. The previous versions of this Recommendation published case. JJG 22-2003 JJG 22-1991 JJG 22-1981 JJG 22-75 Micrometer diameter test procedures1 ScopeThe order applies to. indexing is 0.01mm or resolution of 0.001mm, micrometer range indication 13mm, 25mm, 50mm, measurement limit of not more than 6000mm of connecting rod inside micrometer, a single shot point inside Micrometer, digital micrometer diameter connecting rod and several significant single shot inside micrometer (hereinafter referred to as micrometer diameter) of the first seizure Set, and use the subsequent verification check. 2. References This procedure references the following documents. GB/T 8177 two micrometer diameter GB/T 22093-2008 electronic digital micrometer diameter For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.3 OverviewInside micrometer for measuring the inner diameter of the workpiece, the groove width and the distance between the two inner surfaces. The main structure In the form of Arbors were inside micrometer (see Figure 1), a single shot inside micrometer (see Figure 2), digital Post-point inside Feet (see Figure 3), digital single shot inside micrometer (see Figure 4). Figure 1 connecting rod inside micrometer schematic 1 - Fixed probe; 2- Take pole; 3 - locking device; 4- micrometer; 5- fixed casing; 6- differential cylinder; 7- adjustable probe2 single rod inside micrometer schematic1 - Fixed probe; 2- locking device; 3- fixed casing; 4- differential cylinder; 5- adjustable probe ...... |