JJG 2071-2013 English PDFUS$239.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 2071-2013: Verification scheme of Measuring Instruments for Pressure Range (-2.5~2.5) kPa Status: Valid JJG 2071: Historical versions
Basic dataStandard ID: JJG 2071-2013 (JJG2071-2013)Description (Translated English): Verification scheme of Measuring Instruments for Pressure Range (-2.5~2.5) kPa Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A53 Classification of International Standard: 17.100 Word Count Estimation: 10,176 Older Standard (superseded by this standard): JJG 2071-1990 Regulation (derived from): AQSIQ Announcement No. 63 of 2013 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to: (-2. 5 to 2. 5) kPa pressure within the range of pressure measuring instruments money transfer. This table provides verification system within this pressure range baseline measurement apparatus the pressure gauge the name, range, JJG 2071-2013: Verification scheme of Measuring Instruments for Pressure Range (-2.5~2.5) kPa---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification scheme of Measuring Instruments for Pressure Range (-2.5 ~ 2.5) kPa People's Republic of China National Metrological Verification System tables (-2.5 ~ 2.5) kPa pressure measuring instruments MeasuringInstrumentsforPressureRange (-2.5 ~ 2.5) kPa Issued on. 2013-01-06 2013-07-06 implementation The State Administration of Quality Supervision, Inspection and Quarantine released (-2.5 ~ 2.5) kPa Pressure measuring instruments Verification System PressureRange (-2.5 ~ 2.5) kPa Replacing JJG 2071-1990 Focal point. the National Technical Committee of pressure measurement The main drafting units. China Institute of Metrology Participated in the drafting. Zhejiang Provincial Institute of Metrology China Testing Technology Research Institute Shanghai Measurement and Testing Technology Research Institute The Verification System commissioned the National Technical Committee of pressure measurement shall be interpreted The main drafters of the table. CRITICAL (China Institute of Metrology) Yue Jin (China Institute of Metrology) Drafters participate. Cai Fei (Zhejiang Institute of Metrology) Gan Rong (China Testing Technology Research Institute) Hung flat (Shanghai Institute of Measurement and Testing) Far more than Yang (China Institute of Metrology) table of Contents1 Scope (1) 2 baseline measurement (1) 3 measurement standards (1) 4 working measuring instruments (3) 5 (-2.5 ~ 2.5) kPa pressure measuring instruments Verification System block diagram (3) (-2.5 ~ 2.5) kPa pressure measuring instruments Verification System1 ScopeThe Verification System applies (-2.5 ~ 2.5) kPa pressure range of pressure measuring instruments of value transfer. this Verification System provides name within this pressure range baseline measurement instruments pressure measuring instruments, measuring range, with Transit, transfer method, reproduce the magnitude of uncertainty (or value transfer should be to achieve the best measurement capability) to Composition and working standards of measurement and measuring instruments of pressure measuring instruments name, range, use, transfer Party Method and the maximum permissible error; specifies the amount of pressure within the pressure range is transmitted to the State by reference standards of measurement Delivery methods and measuring instruments work pipeline.2 baseline measurement2.1 baseline measurement name. 2500Pa pressure reference devices. 2.2 Scope of the baseline measurement uncertainty and composition Pressure Range. (- 2.5 ~ 2.5) kPa. Uncertainty. 0.13Pa (k = 2). 2500Pa pressure reference device uses the principle of compensation, the use of displacement of the movable container to compensate for pressure changes Fixed container caused by changes in the level of zero. It mainly consists of a container system (including fixed container and movable container) Heated water tank, zero positioning system, the displacement measurement system. Its working medium is deionized water. 2.3 magnitude baseline measurement traceability and guarantee 2500Pa pressure reference device by measuring the density of the working medium, and the gravity field measurements Highly accurate measurement so as to reproduce the pressure of traceability to length, mass, time, three basic amount. By participating in international quality and related amounts Advisory Committee on Metrology (CCM) or the Asia-Pacific Metrology Key (APMP) organization than to ensure that the magnitude of the pressure of international pressure magnitude unity. 2.4 reference measurement value transfer 2500Pa pressure reference device direct comparison method to deliver first-class standard to compensate the decline of pressure meter, the maximum allowed Error of ± 0.3Pa to ± 0.5Pa liquid pressure gauge, the maximum permissible error of ± 0.25Pa live micro-pressure gas Plug gauge.3 measurement standardMicro pressure measurement standard equipment including first-class standard to compensate the decline of pressure meter and second standard to compensate the decline of pressure gauge, pressure liquid formula Gauge, micro-pressure gas piston gauge and digital pressure gauge and so on. First decline of 3.1 standard compensation pressure gauge measuring range (-2.5 ~ 2.5) kPa, when the pressure value in (-1.5 To 1.5) kPa within the range, the maximum permissible error of ± 0.4Pa; pressure values at (-2.5 ~ -1.5) And within kPa (1.5 ~ 2.5) kPa range (excluding -1.5kPa and 1.5kPa), the maximum permissible error ± 0.5Pa. First compensation standard micro-pressure meter traceable to 2500Pa pressure reference means; direct comparison with the traditional method of Delivery second-class standard compensation micro-manometer, the maximum permissible error of ± 1.0Pa ~ ± 1.3Pa liquid manometer, maximum ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 2071-2013_English be delivered?Answer: Upon your order, we will start to translate JJG 2071-2013_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 2071-2013_English with my colleagues?Answer: Yes. The purchased PDF of JJG 2071-2013_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 2071-2013?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2071-2013 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |