Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 2060-2014 PDF English

US$170.00 · In stock · Download in 9 seconds
JJG 2060-2014: pH (acidity) Measuring instrument
Delivery: 9 seconds. True-PDF full-copy in English & invoice will be downloaded + auto-delivered via email. See step-by-step procedure
Status: Valid

JJG 2060: Historical versions

Standard IDUSDBUY PDFDeliveryStandard Title (Description)Status
JJG 2060-2014170 Add to Cart Auto, 9 seconds. pH (acidity) Measuring instrument Valid
JJG 2060-1990199 Add to Cart 2 days Verification Scheme of pH(acidity)Measuring Instruments Obsolete

Similar standards

GB/T 12519   HJ 377   JJF 2060   

JJG 2060-2014: pH (acidity) Measuring instrument

---This is an excerpt. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.), auto-downloaded/delivered in 9 seconds, can be purchased online: https://www.ChineseStandard.net/PDF.aspx/JJG2060-2014
JJG METROLOGICAL VERIFICATION INDUSTRY STANDARD OF THE PEOPLE’S REPUBLIC OF CHINA pH (acidity) Measuring instrument ISSUED ON: AUGUST 25, 2014 IMPLEMENTED ON: FEBRUARY 25, 2015 Issued by: General Administration of Quality Supervision, Inspection and Quarantine of PRC

Table of Contents

Introduction ... 5 1 Scope ... 6 2 Metering reference ... 6 2.1 Reference range and expanded uncertainty ... 6 2.2 Reference measuring device... 6 3 Metering standards ... 7 3.1 pH first-level standard material ... 7 3.2 pH second-level standard material ... 7 3.3 Electrical meter verification device for pH meter ... 7 4 Working measuring instruments ... 8 4.1 Laboratory pH meter ... 8 4.2 Online pH meter ... 8 4.3 Others ... 8 5 Block diagram of verification system of pH (acidity) measuring instrument .. 8 Appendix A Composition of pH first-level standard material and its standard solution ... 10 Appendix B The pH value of pH first-level standard solution ... 11 pH (acidity) Measuring instrument

1 Scope

This verification system table is suitable for the transfer of pH (acidity) measuring instruments. It specifies the method and procedure for transferring the pH (acidity) value from the metering reference to the working measuring instruments at all levels through metering standard, as well as the optimal measuring capability when the value is transferred. When carrying out calibration, it can also be used as a basis for traceability of the value.

2 Metering reference

2.1 Reference range and expanded uncertainty The national reference is used to reproduce and preserve the pH scale of aqueous solutions. The range of the national reference reproduced pH ranges from 0 to 14 (0 °C to 95 °C); the extended uncertainty is 0.005 (k = 3). The national reference adopts the Harned-cell reference battery method without liquid junction, which realizes the traceability to the SI basic units of thermodynamic temperature, current, time, length, mass, etc. through the measurement of battery potential, temperature, gas pressure, etc. 2.2 Reference measuring device The reference measuring device consists of the following instruments and equipment: Liquid-junction-free reference battery pack (also known as Harned-cell reference battery pack), which is a liquid-junction-free measurement battery pack composed of platinum (palladium) hydrogen electrode as indicator electrode and silver/silver chloride electrode as reference electrode. The battery potential measuring instrument adopts a DC digital voltmeter which has a resolution of 1 μV and a maximum allowable error of no more than ±10 μV. Precision constant temperature water tank: the temperature uniformity of the constant temperature water tank does not exceed 0.01 °C; the temperature verification of the instrument, usually the pH meter verification instrument is used. The measuring range of the pH meter verification device is 0 ~ 14; the DC voltage range is -2V ~ 2V, which is divided into two levels: 0.003 and 0.0006. The electrical meter verification device for pH meter composed of a standard battery and a standard potentiometer shall meet the requirements of the corresponding level of pH meter verification instrument. The electrical meter verification device for pH meter transmits the value to the working measuring instrument through the direct measurement method.

4 Working measuring instruments

Working measuring instruments refer to laboratory pH meters, online pH meters, as well as the ion meters, potentiometric titrators, water quality analyzers, etc. used as pH meters. 4.1 Laboratory pH meter The pH measurement range of the laboratory pH meter is 0 ~ 14; the DC voltage measurement range is -2 V ~ 2 V, which are divided into 0.001, 0.01, 0.02, 0.1, 0.2 levels. 4.2 Online pH meter The pH measurement range of the online pH meter is 0 ~ 14; the DC voltage measurement range is -2 V ~ 2 V, which is divided into 0.01 level and 0.1 level. 4.3 Others For the ion meters, potentiometric titrators, water quality analyzers, etc. used as pH meters, it may, based on the pH measurement ranges and accuracy levels, determine the appropriate pH value transfer path by referring to this calibration system table.

5 Block diagram of verification system of pH (acidity)

measuring instrument The block diagram of the pH (acidity) measuring instrument's verification system is shown in the Figure below. ......

Source: Above contents are excerpted from the full-copy PDF -- translated/reviewed by: www.ChineseStandard.net / Wayne Zheng et al.
Image 1     Image 2     Image 3     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of English version of JJG 2060-2014 be delivered?Answer: The full copy PDF of English version of JJG 2060-2014 can be downloaded in 9 seconds, and it will also be emailed to you in 9 seconds (double mechanisms to ensure the delivery reliably), with PDF-invoice.

Question 2: Can I share the purchased PDF of JJG 2060-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJG 2060-2014_English will be deemed to be sold to your employer/organization who actually paid for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?Answer: Yes. www.ChineseStandard.us -- JJG 2060-2014 -- Click this link and select your country/currency to pay, the exact amount in your currency will be printed on the invoice. Full PDF will also be downloaded/emailed in 9 seconds.

Question 5: Should I purchase the latest version JJG 2060-2014?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2060-2014 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.

How to buy and download a true PDF of English version of JJG 2060-2014?

A step-by-step guide to download PDF of JJG 2060-2014_EnglishStep 1: Visit website https://www.ChineseStandard.net (Pay in USD), or https://www.ChineseStandard.us (Pay in any currencies such as Euro, KRW, JPY, AUD).
Step 2: Search keyword "JJG 2060-2014".
Step 3: Click "Add to Cart". If multiple PDFs are required, repeat steps 2 and 3 to add up to 12 PDFs to cart.
Step 4: Select payment option (Via payment agents Stripe or PayPal).
Step 5: Customize Tax Invoice -- Fill up your email etc.
Step 6: Click "Checkout".
Step 7: Make payment by credit card, PayPal, Google Pay etc. After the payment is completed and in 9 seconds, you will receive 2 emails attached with the purchased PDFs and PDF-invoice, respectively.
Step 8: Optional -- Go to download PDF.
Step 9: Optional -- Click Open/Download PDF to download PDFs and invoice.
See screenshots for above steps: Steps 1~3    Steps 4~6    Step 7    Step 8    Step 9