JJG 2048-2011 English PDFUS$239.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 2048-2011: Verification Scheme of Measuring Instruments for 500K~1000K Irradiance Scale Status: Valid JJG 2048: Historical versions
Basic dataStandard ID: JJG 2048-2011 (JJG2048-2011)Description (Translated English): Verification Scheme of Measuring Instruments for 500K~1000K Irradiance Scale Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A60 Classification of International Standard: 17.180 Word Count Estimation: 10,118 Date of Issue: 2011-12-28 Date of Implementation: 2012-06-28 Older Standard (superseded by this standard): JJG 2048-1990 Regulation (derived from): AQSIQ Announcement No. 205 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to 500K ~ 1000K radiation measuring instruments measure passed. Provides 500K ~ 1000K full value measurement basis irradiation national measurement standards through the work measurement standards for value transfer procedures, methods and best measurement capability. In carrying out the calibration, can be used as a basis for traceability. JJG 2048-2011: Verification Scheme of Measuring Instruments for 500K~1000K Irradiance Scale---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Scheme of Measuring Instruments for 500K ~ 1000K Irradiance Scale People's Republic of China National Metrological Verification System tables 500K ~ 1000K full radiation measuring instruments MeasuringInstrumentsfor500K ~ 1000KIrradianceScale Issued on. 2011-12-28 2012-06-28 implementation The State Administration of Quality Supervision, Inspection and Quarantine released 500K ~ 1000K whole irradiation Measuring instruments Verification System Instrumentsfor500K ~ 1000 Replacing JJG 2048-1990 The Verification System by the State Administration of Quality Supervision, Inspection and Quarantine on December 28, 2011 Batch Accurate, and implemented since June 28, 2012. Focal point. the National Technical Committee on Optical metrology Drafting units. China Testing Technology Research Institute China Institute of Metrology The Verification System commissioned the National Commission on optical measurement technology to interpret The main drafters. Su Hongyu (China Testing Technology Research Institute) Huo (China Institute of Metrology) Zhang Xianliang (China Testing Technology Research Institute) Drafters participate. On behalf of the Rainbow (China Institute of Metrology) table of Contents1 Scope (1) 2 baseline measurement (1) 2.1 full irradiation reference means (1) 2.2 500K ~ 1000K Irradiation work full reference means (2) 2.3 Measurement value transfer (3) 3 measurement standards (3) 3.1 class Standard (3) 3.2 second standard (3) 4 working measuring instruments (3) 5 500K ~ 1000K full radiation measuring instruments Verification System block diagram (4) 500K ~ 1000K full radiation measuring instruments Verification System1 ScopeThe verification system applicable to 500K ~ 1000K value transfer radiation measuring instruments. It provides 500K ~ 1000K whole irradiation national measurement reference value (hereinafter referred to as "full irradiation reference") by measurement standards to working measuring Standard apparatus for value transfer procedures, methods and best measurement capability. In carrying out the calibration, but also as a measure traceability Source basis.2 baseline measurementFull reference radiation for reproduction and preservation of 500K ~ 1000K whole units measure radiation, and by the standards of measurement Working measuring instruments of value transfer. Full reference reproducible irradiation unit as an internal legal temperature range of 500K ~ 1000K radiation provided Highest standards integral irradiance and irradiance infrared detector integration of traceability. 2.1 full irradiation reference means 500K ~ 1000K whole irradiation by reference means a reference blackbody source and accuracy with suitable measuring Equipment. 2.1.1 reference blackbody source 2.1.1.1 working in a metal solidification point of the absolute blackbody radiation temperature --- reproduce natural reference point, the whole In accordance with the highest radiation measured at four metals freezing point blackbody group, effective emissivity of blackbody cavity which is not less than 0.9999, Uncertainty Uε 0.05% (coverage factor k = 2), International Temperature Scale ITS-90. Indium (In). 156.5985 ℃; Tin (Sn). 231.928 ℃; Zinc (Zn). 419.527 ℃; Aluminum (Al). 660.323 ℃. 2.1.1.2 reference blackbody source metrological performance requirements as shown in Table 1. Table 1 metrological requirements Category Technical indicators parameter Cavity geometry parameters Effective radiating diameter ≥20mm Cavity length ratio L/R (L is the total length of the cavity, R is the radius of the chamber opening) ≥15 Concentricity deviation (effective radiating center, the center of the mouth cavity blackbody The front surface of the center of the opening) ≤0.5mm Temperature characteristics Metal freezing point must be the international temperature scale ITS-90 specified by a Class of temperature points Freezing point temperature plateau duration ≥40min Freezing point difference between the measured temperature value ≤30mK International Temperature Scale ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 2048-2011_English be delivered?Answer: Upon your order, we will start to translate JJG 2048-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 2048-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJG 2048-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 2048-2011?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 2048-2011 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |