Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 185-2017 English PDF

US$329.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 185-2017: Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method)
Status: Valid

JJG 185: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJG 185-2017329 Add to Cart 3 days Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method) Valid
JJG 185-2004RFQ ASK 3 days Locomotive speed meter testing procedures
JJG 185-1997359 Add to Cart 3 days Verification Regulation of Measuring Hydrophone in the Frequency Range 500Hz to 1 MHz Obsolete
JJG 185-1978RFQ ASK 3 days Verification Regulation of Standard Hydrophone (Grade II) Obsolete

Similar standards

GB/T 3222.2   GB/T 3222.1   JJG 188   JJG 921   JJG 175   

Basic data

Standard ID: JJG 185-2017 (JJG185-2017)
Description (Translated English): Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method)
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A59
Word Count Estimation: 14,120
Date of Issue: 2017-11-20
Date of Implementation: 2018-05-20
Older Standard (superseded by this standard): JJG 185-1997
Regulation (derived from): AQSIQ Notice 2017 No. 103
Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine

JJG 185-2017: Standard Hydrophones in the Frequency Range 500 Hz to 1 MHz(Free-field Comparison Method)


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(500Hz ~ 1MHz standard hydrophone test procedures (free field comparison method)) National Metrology Verification Regulations of the People's Republic 500Hz~1MHz standard hydrophone (free field comparison method) Range500Hzto1MHz (Free-fieldComparisonMethod) Released on.2017-11-20 2018-05-20 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued 500Hz~1MHz standard hydrophone (free field comparison method) verification procedure Replace JJG 185-1997 Focal Point. National Acoustic Metrology Technical Committee Drafted by. China Testing Technology Research Institute Institute of Acoustics China Shipbuilding Industry Corporation Seventh Five-Year Research Institute Shenzhen Institute of Metrology and Quality Inspection This procedure entrusts the National Acoustic Metrology Technical Committee to explain Drafters of this procedure. Sun Lei (China Testing Technology Research Institute) Mo Xiping (Institute of Acoustics, Chinese Academy of Sciences) Zhao Han (Seventh Five-Year Research Institute of China Shipbuilding Industry Corporation) Zhang Guoqing (Shenzhen Metrology and Quality Inspection Institute)

table of Contents

Introduction (II) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Hydrophone (1) 3.2 Standard hydrophone (1) 3.3 Free field sensitivity (1) 3.4 Free field sensitivity level (2) 3.5 Free field comparison method (2) 3.6 Electrical Transfer Impedance Mode (2) 3.7 Reference Center (2) 4 Overview (2) 5 Metrological performance requirements (2) 5.1 Free field sensitivity level (2) 5.2 Free field sensitivity level frequency response (2) 6 General technical requirements (3) 6.1 Appearance (3) 6.2 Marking and ex-factory information (3) 6.3 Normal work (3) 7 Measuring instrument control (3) 7.1 Verification conditions (3) 7.2 Verification project (4) 7.3 Verification method (5) 7.4 Processing of verification results (7) 7.5 Verification cycle (7) Appendix A Format of Internal Page of Verification Certificate and Verification Result Notice (8)

Introduction

This procedure is a revision of JJG 185-1997 "500Hz ~ 1MHz measuring hydrophone". The basis for this revision is the IEC 60565.2006 "Water Acoustic Hydrophone in the frequency range of 0.01 Hz to 1 MHz. calibration". Compared with JJG 185-1997, the main revisions are. --- The name of the procedure was changed to "500Hz~1MHz standard hydrophone (free field comparison method)"; --- The terms used are based on the terms and definitions in JJF1001-2011 General Terms and Definitions; ---Add reference files; --- Increase general technical requirements; --- Remove the sensitivity (response) level and sensitivity (response) conversion table. The previous versions of this procedure were released as follows. ---JJG 185-1997. 500Hz~1MHz standard hydrophone (free field comparison method) verification procedure

1 Scope

This procedure applies to the first verification and follow-up of standard hydrophones used in the frequency range of 500 Hz to 1 MHz. Verification and inspection in use.

2 reference files

This procedure refers to the following documents. JJF1001-2011 General Measurement Terms and Definitions JJF1034-2005 Acoustic measurement terminology and definition GB/T 3102.7-1993 The amount and unit of acoustics GB/T 3947-1996 acoustic terminology IEC 60565.2006 Hydroacoustic hydrophone calibration from 0.01 Hz to 1 MHz (Underwater) acoustics-Hydrophone-Calibrationinthefrequencyrange0.01Hzto1MHz) For dated references, only the dated version applies to this Code; any undated quotation The latest version (including all amendments) applies to this procedure.

3 terms and units of measure

This procedure uses the relevant terms in JJF1001-2011, JJF1034-2005, GB/T 3947-1996 and definition. This procedure uses the quantities and units specified in GB/T 3102.7-1993. Note. Unless otherwise stated, all voltage values in this specification refer to the effective value. 3.1 hydrophone hydrophone An electroacoustic transducer for receiving a hydroacoustic signal. Note. due to different working principles, characteristics and construction, there are sound pressure, sound pressure gradient, undirected, pointed, piezoelectric, optical fiber, etc. Listener. [GB/T 3947-1996, definition 7.81] 3.2 standard hydrophone standardhydrophone A stable, absolutely calibrated transducer for hydroacoustic metrology. Often used as a reference for establishing sound pressure in water The standard is used to pass the sound pressure value. [GB/T 3947-1996, definition 7.82] 3.3 Free field sensitivity free-fieldsensitivity Receiving the open circuit voltage at the output of the transducer, and presenting itself at the center of the transducer before the introduction of the transducer in the sound field The ratio of the sound pressure from the field.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 185-2017_English be delivered?

Answer: Upon your order, we will start to translate JJG 185-2017_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 185-2017_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 185-2017_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 185-2017?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 185-2017 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.