Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 182-2005 English PDF

US$389.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 182-2005: Verification Regulation of Micrometers with Prismatically Arranged Measuring Faces
Status: Valid

JJG 182: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJG 182-2005389 Add to Cart 3 days Verification Regulation of Micrometers with Prismatically Arranged Measuring Faces Valid
JJG 182-2004RFQ ASK 3 days Alternating-Current Electrical Energy Meters for Electric Locomotive
JJG 182-1993399 Add to Cart 3 days Verification Regulation of V-Shape Anvil Micrometers Obsolete
JJG 182-1978RFQ ASK 3 days (Chinese Industry Standard) Obsolete

Similar standards

JJG 517   JJG 5   JJG 0061   JJG 601   JJG 191   JJG 177   

Basic data

Standard ID: JJG 182-2005 (JJG182-2005)
Description (Translated English): Verification Regulation of Micrometers with Prismatically Arranged Measuring Faces
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A52
Classification of International Standard: 17.040
Word Count Estimation: 15,179
Date of Issue: 2005-10-09
Date of Implementation: 2006-04-09
Older Standard (superseded by this standard): JJG 182-1993
Summary: This standard applies to the measurement limit is less than 100mm, indexing is 0. 01mm, 0. 001mm, 0. 002mm, 0. 005mm three groove micrometer, five ditch micrometer and seven ditch micrometer (hereinafter referred to as "odd ditch micrometer") of the first test, follow-up test and use test.

JJG 182-2005: Verification Regulation of Micrometers with Prismatically Arranged Measuring Faces


---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Verification Regulation of Micrometers with Prismatically Arranged Measuring Faces National Metrology Verification Regulations of the People's Republic Odd ditch micrometer Released on October 10,.2005 2006-04-09 implementation The General Administration of Quality Supervision, Inspection and Quarantine issued Replace JJG 182-1993 This regulation was approved by the General Administration of Quality Supervision, Inspection and Quarantine on October 9,.2005, and Implemented on April 9,.2006. Focal Point. National Geometric Quantity Engineering Measurement Technology Committee Drafting unit. Heilongjiang Province Metrology Testing and Testing Institute Harbin Metrology Testing and Testing Institute Harbin Electric Machinery Co., Ltd. Harbin First Tools Co., Ltd. This regulation entrusts the National Geometric Quantity Engineering Parametric Measurement Technical Committee to explain Drafters of this procedure. Ma Wei (Heilongjiang Metrological Testing and Testing Institute) Wang Li (Harbin Metrology Testing Institute) Jinyun Library (Harbin Electric Machinery Co., Ltd.) Sun Xingfan (Harbin First Tools Co., Ltd.)

table of Contents

1 Scope (1) 2 Citations (1) 3 Overview (1) 4 Metrology performance requirements (1) 4.1 Force (1) 4.2 scribe line width and width difference (1) 4.3 Relative position of the end face of the differential cone surface and the millimeter line on the fixed sleeve (1) 4.4 Distance from the tapered edge of the differential cone to the scribed plane of the fixed sleeve (2) 4.5 Surface roughness of measuring surface for measuring surface and proofing (2) 4.6 Measuring plane flatness (2) 4.7 Parallelism of the measuring surface of the micrometer screw relative to the measuring surface of the measuring anvil (2) 4.8 indication error (2) 4.9 Proofreading size (2) 4.10 Digital Display Unit (3) 5 General technical requirements (3) 5.1 Appearance (3) 5.2 Interaction of various parts (3) 6 measuring instrument control (3) 6.1 Verification project (3) 6.2 Verification conditions (3) 6.3 Verification method (4) 6.4 Processing of verification results (6) 6.5 verification period (6) Appendix A Evaluation of Uncertainty in Measurement Results of Odd-numbered Millimeter Indicator Errors (7) Appendix B Verification Certificate and Verification Result Notice (inside page) format (10) Odd ditch micrometer verification procedure

1 Scope

This procedure applies to the upper limit of measurement less than 100mm; the division value is 0.01mm, 0.001mm, 0.002mm, 0.005mm three-channel micrometer, five-channel micrometer and seven-channel micrometer (hereinafter referred to as "odd groove micrometer") First verification, follow-up verification and in-use inspection.

2 Citations

This procedure refers to the following documents. JJF1001-1998 General measurement terms and definitions JJF1059-1999 Measurement Uncertainty Evaluation and Representation JJF1094-2002 Technical Specifications for Measuring Instrument Characteristics GB/T 9058-2004 odd ditch micrometer When using this procedure, care should be taken to use the current valid version of the above cited documents.

3 Overview

The odd-numbered ditch micrometer is a length measuring instrument using a spiral vice principle and a V-shaped anvil, and its outline drawing and The differential structure is shown in Figure 1. It is mainly used to measure the production of odd bisectors and teeth (such as taps, reapers, etc.). Measuring tool for diameter size. The odd-numbered ditch micrometer is divided into three types. three ditch micrometers, five ditch micrometers, and seven ditch micrometers. Three groove micrometer V-shaped surface The angle α is 60°, and the measurement range is (1~15)mm, (5~20)mm, (20~35)mm, (35~50)mm, (50~65)mm, (65~80)mm six kinds; the five-channel micrometer V-shaped surface angle α is 108°, the measurement range is (5~25)mm, (25~45)mm, (45~65)mm, (65~85)mm four; seven groove micrometer V shape The angle α of the surface is 128°34'17′′, and the measurement range is (5~25)mm, (25~45)mm, (45~65)mm. (65~85) mm four.

4 Metrological performance requirements

4.1 Force measurement The odd-numbered micrometer measuring force should be in the range of (5~10)N. 4.2 scribe line width and width difference The width of the longitudinal line on the fixed sleeve and the score line on the differential cylinder are (0.15~0.20) mm, and the difference in the width of the line is not More than 0.03mm. 4.3 The relative position of the end face of the tapered cone and the millimeter line on the fixed sleeve When the lower limit of the measurement is adjusted correctly, when the zero line of the differential cylinder is aligned with the longitudinal line of the fixed sleeve, the cone of the differential tube The end face should be tangent to the right edge of the fixed casing. If it is not tangent, the pressure line should not exceed 0.05mm, and the line should not exceed 0.1mm.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 182-2005_English be delivered?

Answer: Upon your order, we will start to translate JJG 182-2005_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 182-2005_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 182-2005_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 182-2005?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 182-2005 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.