JJG 13-2016 English PDFUS$439.00 ยท In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 13-2016: Analogue Indicating Weighing Instruments Status: Valid JJG 13: Historical versions
Basic dataStandard ID: JJG 13-2016 (JJG13-2016)Description (Translated English): Analogue Indicating Weighing Instruments Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A53 Word Count Estimation: 19,115 Date of Issue: 2016-03-03 Date of Implementation: 2016-09-03 Older Standard (superseded by this standard): JJG 13-1997 Quoted Standard: JJG 99; JJF 1181 Regulation (derived from): Announcement No.26 of the General Administration of Quality Supervision, Inspection and Quarantine Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine JJG 13-2016: Analogue Indicating Weighing Instruments---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Analogue Indicating Weighing Instruments National Metrological Verification Regulation of the People's Republic of China Simulation indicator scale 2016-03-03 release 2016-09-03 Implementation State Administration of Quality Supervision, Inspection and Quarantine issued Simulation of the scale test procedures Replacing JJG 13-1997 Responsible unit. National Weighing Measurement Technology Committee The main drafting unit. Hangzhou Quality and Technical Supervision and Inspection Institute Qingdao Weighing Test Center Participated in the drafting unit. Harbin Metrology and Testing Institute Shandong Institute of Metrology This procedure entrusts the National Weighing Metrology Technical Committee to explain The main drafters of this procedure. Zhang Yuehai (Hangzhou Quality and Technical Supervision and Inspection Institute) Li Zhifei (Hangzhou Quality and Technical Supervision and Inspection Institute) Miao Chunfa (Qingdao Weighing Test Center) Participate in the drafters. Jinlong Xue (Harbin Metrology and Testing Institute) Liu Ping (Shandong Institute of Metrology) table of ContentsIntroduction (II) 1 Scope (1) 2 References (1) 3 terms and units of measurement (1) 3.1 Terms (1) 3.2 Unit of measurement (1) 4 Overview (1) 5 Measurement performance requirements (2) 5.1 Division of accuracy levels (2) 5.2 Test division value (2) 5.3 The maximum allowable error of the scale (2) 5.4 Repeatability (2) 5.5 partial load (when applicable) (2) 5.6 Rotation (when applicable) (3) 5.7 Multiple Indicator (if applicable) (3) 5.8 Authentication threshold (3) 6 General technical requirements (3) 6.1 Safety of measurement (3) 6.2 Metrological markings and metrological instruments (3) 7 Metering device control (4) 7.1 Standard equipment for testing (4) 7.2 Verification Project (4) 7.3 Inspection of general technical requirements (4) 7.4 Measurement performance test (4) 7.5 Processing of test results (6) 7.6 Verification cycle (6) Appendix A Simulation Indicator Scale Verification Record Format (Recommended) (7) Appendix B Multi-Indicator Device Simulation Indicator Scale Record Format (Recommended) (9) Appendix C Verification Certificate Page Format (Recommended) (11) Appendix D Test results Notification page format (recommended) (13)IntroductionThe JJG 13-1997 "simulation indicator" test procedures to amend the implementation of the format in the implementation of the JJF1002-2010 "Rules for the preparation of national metrological verification procedures". Compared with JJG 13-1997, in addition to editorial changes The main changes are the following. - Added some of the necessary terms related to metrological verification (see 3.1); - specifies the legal units of measurement that must be used by the analogue indicator (see 3.2); - modified the diameter requirements of the self-adhesive type check mark position in the test qualification mark [see 6.2.3d)]; - a list of approved items (see 7.2); - modified inspection in use only for general technical requirements (see 6); - the allowable error between the weighing results is deleted; - increased the use of anti-fraud features (see 6.1); --- remove the standard weight alternative way; - modified repetitive verification requirements (see 7.4.3); - the removal of the relevant requirements for "more than four support points" in the partial load test (see 7.4.4); - Added "Verification Record Format" (see Appendix A, Appendix B); - Added "Verification certificate page format" (see Appendix C); --- Added "Verification results page format" (see Appendix D). The previous versions of this order are released as follows. --- JJG 13-1997; --- JJG 13-1986. Simulation of the scale test procedures1 ScopeThis procedure applies to the country according to the law of the accuracy of the level and the general accuracy of the simulation indicator scale (hereinafter referred to as Scale) of the first test, follow-up test and use in the inspection. Does not apply to the hospital and the family with the scale.2 reference fileJJG 99 weight JQF1181 Weighing Terms and Definitions For dated references, only the dated edition applies to this rule; references that are not dated , The latest version (including all amendments) applies to this procedure.3 terms and units of measurement3.1 terminology The terminology used in this procedure is consistent with the terminology of JJF1181, which is easy to use and easy to understand. Add the following terms. 3.1.1 multi-indication device multi-indicatingdevice The device that displays the same weighing result on the positive and negative analog dial. 3.1.2 discrimination threshold discrimination threshold Causing the corresponding indication to not detect the maximum change in the measured value of the change. 3.1.3 lead leadsealing A seal mark with a metal lead or lead alloy used to prevent any unauthorized modification of the scale. The physical markings of the whole or removed parts. Including the manufacturer's factory inspection qualified seal and the certification body of the test qualified Seal. 3.1.4 minimum capacity (Min) minimumcapacity (Min) Less than the load value, the weighing results will produce too large relative error. The load value is called the minimum weighing. 3.1.5 Maximum capacity (Max) maximumcapacity (Max) Regardless of the maximum weighing capacity when adding tare. 3.1.6 load load Due to gravity, the load on the scale of the loader is called the items, and sometimes directly refers to their force. Note. Loads include weights or other items with stable values. 3.2 Units of measurement The unit of measurement used in the scale shall be the legal unit of measurement, including. kg (kg), g (g).4 OverviewThe analogue indicator is a non-automatic weighing instrument. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 13-2016_English be delivered?Answer: Upon your order, we will start to translate JJG 13-2016_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 13-2016_English with my colleagues?Answer: Yes. The purchased PDF of JJG 13-2016_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 13-2016?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 13-2016 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |