JJG 1181-2021 English PDFUS$379.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1181-2021: Verification Regulation of γ Radiation Sources Used in Body Stereotactic Radiation Therapy Status: Valid
Basic dataStandard ID: JJG 1181-2021 (JJG1181-2021)Description (Translated English): Verification Regulation of �� Radiation Sources Used in Body Stereotactic Radiation Therapy Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A58 Classification of International Standard: 17.240 Word Count Estimation: 17,195 Date of Issue: 2021-12-08 Date of Implementation: 2022-06-08 Issuing agency(ies): State Administration for Market Regulation Summary: This standard applies to the initial verification, follow-up verification and in-use inspection of the Y-radiation therapy source for body stereotaxic radiosurgery (hereinafter referred to as the Y-knife for the body). JJG 1181-2021: Verification Regulation of γ Radiation Sources Used in Body Stereotactic Radiation Therapy---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. National Metrology Verification Regulations of the People's Republic of China Stereotactic body radiosurgery gamma radiation healing source Released on 2021-12-08 2022-06-08 Implementation Released by the State Administration for Market Regulation Stereotactic body radiosurgery gamma radiation source of healing Responsible unit: National Technical Committee of Ionizing Radiation Metrology Main drafting unit: Henan Institute of Metrology Zhengzhou People's Hospital Shandong Institute of Metrology Participating in the drafting unit: Zhejiang Institute of Metrology This specification entrusts the National Ionizing Radiation Metrology Technical Committee to be responsible for interpretation The main drafters of this regulation: Long Chengzhang (Henan Institute of Metrology) Li Huaiyu (Zhengzhou People's Hospital) Wang Panfeng (Henan Institute of Metrology) Liu Yang (Shandong Institute of Metrology) Participating drafters: Wang Shuangling (Henan Institute of Metrology) Liu Hui (Henan Institute of Metrology) Mei Jie (Zhejiang Institute of Metrology) Table of contentsIntroduction (Ⅱ) 1 Scope(1) 2 References(1) 3 Terms and units of measurement(1) 3:1 Terminology(1) 3:2 Units of measurement(1) 4 Overview(2) 5 Metrological performance requirements (2) 5:1 Consistency between radiation focus and mechanical isocenter (2) 5:2 Overlapping radiation fields (2) 5:3 Superimposed penumbra(2) 5:4 Output dose(2) 6 General technical conditions (2) 7 Measuring Instrument Control(2) 7:1 Test conditions (2) 7:2 Verification items (3) 7:3 Verification method (4) 7:4 Processing of verification results (6) 7:5 Verification cycle (6) Appendix A Schematic Diagram of Phantom Dimensions (7) Appendix B Schematic Diagram of Focus Measuring Rod (9) Appendix C Original Records of Source Verification of Gamma Radiation Therapy in Stereotactic Body Radiosurgery (10) Appendix D Format of the inner page of the verification certificate (11)IntroductionJJF1001 "General Metrology Terms and Definitions", JJF1002 "Rules for Writing National Metrology Verification Regulations", JJF1059:1 "Assessment and Expression of Measurement Uncertainty" together constitute the basic series supporting the formulation of this regulation specification: This regulation is published for the first time: Stereotactic body radiosurgery gamma radiation source of healing1 ScopeThis regulation is applicable to the first inspection of gamma radiation therapy source for body stereotaxic radiosurgery (hereinafter referred to as body gamma knife): determination, follow-up verification and in-use inspection:2 ReferencesThis procedure references the following documents: JJF1001 General Metrology Terms and Definitions GB/T 17857-1999 Medical Radiology Terminology (Radiation Therapy, Nuclear Medicine and Radiation Dosimetry Equipment) WS582-2017 X, gamma ray stereotaxic radiotherapy system quality control testing specification YY0831:2-2015 Gamma Beam Stereotactic Radiotherapy System Part 2: Multi-source Gamma Beam Stereotactic Body Body Targeted Radiation Therapy System IAEA Technical Report No: 277 (Second Edition:1997) Absorbed Dosimetry of Photon and Electron Beams, International Use use the regulations For dated references, only the dated version applies to this regulation; for undated references document, its latest version (including all amendments) applies to this regulation:3 Terminology and units of measurement3:1 Terminology The following terms and definitions defined in JJF1001 and JJF1035 are applicable to this regulation: 3:1:1 collimator A device for collimating a beam of radiation emerging from a source: 3:1:2 focus focus The intersection point of the beam axes: A three-dimensional radiation field composed of several radiation sources arranged in a certain latitude and longitude: 3:1:4 superimposed penumbra penumbraoverlap The 20%~80% area of the maximum dose value of the superimposed radiation field is referred to as the penumbra: 3:2 Units of measurement 3:2:1 Unit of air kerma and absorbed dose: gray [ray]; symbol: Gy: 3:2:2 Time unit: second; symbol: s: 3:2:3 Temperature unit: Celsius; symbol: °C: 3:2:4 Air pressure unit: Pa [scal]; symbol: Pa: ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1181-2021_English be delivered?Answer: Upon your order, we will start to translate JJG 1181-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 1181-2021_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1181-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |