JJG 1119-2015 English PDFUS$439.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1119-2015: Load Measurement Apparatus of Electric Weighing Instrument Status: Valid
Basic dataStandard ID: JJG 1119-2015 (JJG1119-2015)Description (Translated English): Load Measurement Apparatus of Electric Weighing Instrument Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A53 Classification of International Standard: 17.100 Word Count Estimation: 19,134 Date of Issue: 2015-08-24 Date of Implementation: 2015-11-24 Quoted Standard: JJG 99; JJG 391-2009; JJG 539; JJF 1181; GB/T 7723; OIML R76-1-2006 (E) Regulation (derived from): AQSIQ Announcement 2015 No.106 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to the instrument load measurement instrument (a kind of test maximum capacity of not less than 30 t, verification scale intervals no greater than in the general accuracy and accuracy of electronic truck scale apparatus 3000, and hereinafter referred to as meter) initial verification and follow-up verification. JJG 1119-2015: Load Measurement Apparatus of Electric Weighing Instrument---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.(Weighing load meter verification procedures) State verification procedures People's Republic of China Weighing load measuring instrument Issued on. 2015-08-24 2015-11-24 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Weighing load meter verification procedures Focal point. the National Technical Committee of measurement scales Main drafting unit. Fujian Institute of Metrology Participated in the drafting. Suzhou Institute of Metrology Shaanxi Provincial Institute of Metrology Qinghai metrological verification tests Gansu Province Institute of Metrology The measurement procedure commissioned the National Technical Committee is responsible for interpreting scales The main drafters of this procedure. Yao Jinhui (Fujian Institute of Metrology) Chen Xindong (Fujian Institute of Metrology) Drafters participate. Dong Chenguang (Suzhou City Metrology Institute) Xu Qian Yu (Shaanxi Provincial Institute of Metrology) Zushao Hu (Qinghai metrological verification tests) Han Xinghai (Gansu Province Institute of measurement) table of ContentsIntroduction (Ⅲ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (2) 4 Overview (2) 5 metering performance requirements (2) 5.1 standard load cell technology indicators (2) 5.2 Technical Specifications Standard load unit group (3) 6 General Requirements (3) 6.1 Appearance (3) 6.2 Electrical Safety (3) 6.3 Measuring Instruments logo (3) 7 control of measuring instruments (4) 7.1 Calibration with standard equipment (4) 7.2 test conditions (4) 7.3 Verification Project (4) 7.4 General Check the technical requirements (4) 7.5 Performance Measurement Verification (5) 7.6 Verification Results Processing (8) 7.7 test cycle (8) Appendix A load measuring instrument Calibrating the original records (recommended) format (9) Appendix B Weighing load measuring instrument calibration certificate within the page (recommended) format (11) Appendix C Weighing load measuring instrument test results in the notice page (recommended) format (13)IntroductionThe main reference regulations of the International Organization of Legal Metrology OIMLR76-1.2006 (E) "the first non-automatic weighing instruments Part I. metrological and technical requirements --- test "(Non-automaticweighinginstrumentsPart 1. Me- trologicalandtechnicalrequirement-Test) and JJG 539 "digital indicating scale test procedures" relating to Auxiliary verification device independent electronic truck scale verification of the relevant technical requirements, technical specifications and test methods. In the series Write the implementation JJF1002-2010 "national verification procedures to write rules" on the format. This procedure is the first release. Weighing load meter verification procedures1 ScopeThis procedure applies to the instrument load measurement instrument (a kind of test maximum capacity of not less than 30t, verification scale intervals of not more than The accuracy and the general accuracy of electronic truck scale apparatus 3000, hereinafter referred to as meter), and after initial verification Continued verification. 2. References JJG 99 weight JJG 391-2009 force sensor JJG 539 Digital Indicating Scales JJF1181 metrological terminology and definitions GB/T 7723 fixed electronic scales OIMLR76-1.2006 (E) non-automatic weighing Part I. metrological and technical requirements --- test (Non-automaticweighinginstrumentsPart 1. Metrologicalandtechnicalrequirement-Test) For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.3 terminology and units of measurement3.1 Terms JJF1181 defined and the following terms and definitions apply to this procedure. 3.1.1 standard load cell standardloadunit Unit consists of a hydraulic cylinder, reaction devices, sensors and measuring instruments and other components for applying standards for truck Load. 3.1.2 standard load unit group asetofstandardloadunits It means a combination of two or more standard load units. 3.1.3 load fluctuation loadfluctuation At rated load, within a certain time, the rated output becomes standard load cell or load cell set the standard Of the amount. 3.1.4 Zero Temperature Effect on Output temperatureeffectonzerooutput Changes in the ambient temperature changes caused by zero output. Usually when the ambient temperature changes caused by zero 10K Percentage point change in output and rated output representation. 3.1.5 rated output temperature temperatureeffectonratedoutput Changes in ambient temperature changes caused by the rated output. The amount is usually the ambient temperature changes caused when 10K Percentage change of the rated output rated output representation. 3.1.6 Stability of stability Under the same conditions the standard load cell within a certain time, the rated output to maintain a constant level. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1119-2015_English be delivered?Answer: Upon your order, we will start to translate JJG 1119-2015_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 1119-2015_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1119-2015_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |