Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJG 111-2019 English PDF

US$419.00 · In stock
Delivery: <= 4 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJG 111-2019: Clinical Thermometers
Status: Valid

JJG 111: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJG 111-2019419 Add to Cart 4 days Clinical Thermometers Valid
JJG 111-2003599 Add to Cart 3 days Verification Regulation of Clinical Thermometers Obsolete
JJG 111-2002RFQ ASK 3 days Railway rolling stock wheel diameter special measuring tools VRof
JJG 111-1989279 Add to Cart 3 days Verification Regulation of Clinical Thermometer Obsolete
JJG 111-1979RFQ ASK 3 days (Chinese Industry Standard) Obsolete

Similar standards

JJG 229   JJF 1187   JJF 1107   JJG 763   JJG 289   JJG 110   

Basic data

Standard ID: JJG 111-2019 (JJG111-2019)
Description (Translated English): Clinical Thermometers
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A54
Classification of International Standard: 17.200
Word Count Estimation: 18,195
Date of Issue: 2019
Date of Implementation: 2020-03-31
Issuing agency(ies): State Administration for Market Regulation

JJG 111-2019: Clinical Thermometers

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Clinical Thermometers National Measurement Verification Regulations of the People's Republic of China Glass thermometer Published on December 31,.2019 2020-03-31 Implementation Issued by the State Administration of Market Supervision and Administration Verification Regulation of Glass Thermometer Replace JJG 111-2003 Centralized unit. National Temperature Measurement Technical Committee Main drafting unit. Shandong Institute of Metrology Beijing Academy of Metrology and Testing Science Participated in the drafting unit. Jinan Changfeng Zhiyuan Instrument Technology Co., Ltd. Shanghai Institute of Metrology and Testing Technology Anhui Institute of Metrology People's Liberation Army General Hospital East Aahua Medical Technology Co., Ltd. This regulation is entrusted to the National Temperature Measurement Technical Committee for interpretation The main drafters of this regulation. Dong Rui (Shandong Institute of Metrology) Yao Min (Beijing Institute of Metrology and Testing Science) Participating drafters. Zhang Jiong (Jinan Changfeng Zhiyuan Instrument Technology Co., Ltd.) Yao Lifang (Shanghai Institute of Metrology and Testing Technology) He Xiaohui (Anhui Institute of Metrology) Zhou Juan (Chinese People's Liberation Army General Hospital) Wang Weijian (Dong Aa Hua Medical Technology Co., Ltd.)

table of Contents

Introduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Terminology (1) 3.1 Scale (1) 3.2 Scale line (1) 3.3 Scale value (1) 3.4 Scale board (1) 3.5 Interrupt (1) 3.6 Gravity (1) 3.7 Difficult to throw (1) 4 Overview (2) 4.1 Principle (2) 4.2 Type (2) 4.3 Uses (2) 5 Measurement performance requirements (2) 6 General technical requirements (2) 6.1 Scales and signs (2) 6.2 Glass rod and glass sleeve (3) 6.3 Internal standard thermometer scale plate (3) 6.4 The tip of the thermometer (3) 6.5 Temperature-sensing bubble (3) 6.6 Temperature sensing fluid (3) 6.7 Temperature sensitive liquid column (3) 7 Control of measuring instruments (3) 7.1 Verification conditions (3) 7.2 Verification items (4) 7.3 Verification method (5) 7.4 Verification data processing (7) 7.5 Processing of verification results (8) 7.6 Verification period (8) Appendix A Verification Method of Multi-branched Thermometer (9) Appendix B Format of the inner pages of the certificate of verification or verification result (10) Appendix C. Reference Format for Verification Records of Glass Thermometers (11) Appendix D Centrifuge speed calculation formula (13)

Introduction

JJF1001-2011 "General Measurement Terms and Definitions", JJF1007-2007 "Temperature Measurement Terms and Definitions "Yi" and "JJF1002-2010" Rules for the Compilation of National Metrology Verification Regulations "together constitute the supporting work for the revision of this regulation Basic norms. This regulation refers to OIMLR7.1979 (E) "(Mercury glass with the highest retention point structure) thermometer" Revise the relevant content such as gauge type, scale, maximum allowable error, etc. This regulation replaces the verification procedure of JJG 111-2003 "Glass Thermometer", and JJG 111-2003 "Glass Body" Compared with the Thermometer, the main technical changes except for editorial changes are as follows. --- Add the second-class standard platinum resistance thermometer as an optional standard; --- Improved the technical requirements of the constant temperature bath; --- Added check in use; --- Deleted some verification items; --- Modified the method of judging the result of indication error; --- Added a description of the method for simultaneously verifying multi-branch thermometers. Previous releases of this regulation. --- JJG 111-2019; --- JJG 111-2003; --- JJG 111-1989. Verification Regulation of Glass Thermometer

1 Scope

This verification procedure is applicable to the measurement range of 30.0 ℃ ~ 43.0 ℃, with the highest retention point structure, the temperature sensitive medium is Liquid glass thermometer (hereinafter referred to as thermometer) for the first verification and inspection in use.

2 Reference documents

This regulation refers to the following documents. JJG 160 standard platinum resistance thermometer JJG 881 standard thermometer JJF1007-2007 Temperature measurement terms and definitions GB 1588 glass thermometer For dated references, only the dated versions are applicable to this Regulation; for those without dates The latest version (including all amendments) is applicable to this regulation.

3 Terminology

The following terms and definitions defined in JJF1007-2007 "Terms and Definitions of Temperature Measurement Terms" and the following apply to this procedure. 3.1 Scale A combination of a set of lines, numbers, and unit of measurement symbols (° C) on the thermometer, used to indicate temperature, also known as Scale. 3.2 Scale line The line engraved on the glass rod or scale plate to indicate the temperature value is also called the scale line. 3.3 scale value The number printed on the glass rod or scale plate to indicate the temperature value is also called the scale value. 3.4 scaleplate Straight, colored (e.g. milky white) thin, engraved scale lines, scale values and other symbols in the internal standard thermometer Piece, also called scale plate. 3.5 Interrupt liquidcolumngap The liquid column of the thermometer is disconnected above the retention point structure. 3.6 Self-liquid liquid column receding solely The phenomenon that the temperature-sensing liquid column of the thermometer retracts toward the temperature-sensing bubble on the part above the retention point structure. 3.7 Liquidcolumnrecedingdifficultly Under a certain external force, it is difficult for the temperature sensing liquid column of the thermometer to retract from above the minimum temperature scale line to the minimum temperature scale The phenomenon below the degree line.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 111-2019_English be delivered?

Answer: Upon your order, we will start to translate JJG 111-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 111-2019_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 111-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 111-2019?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 111-2019 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.