JJG 1101-2014 English PDFUS$399.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1101-2014: Verification Regulation of Medical Diagnostic X-ray Source for Dental Panorama Status: Valid
Basic dataStandard ID: JJG 1101-2014 (JJG1101-2014)Description (Translated English): Verification Regulation of Medical Diagnostic X-ray Source for Dental Panorama Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A58 Classification of International Standard: 17.240 Word Count Estimation: 17,183 Date of Issue: 8/25/2014 Date of Implementation: 11/25/2014 Quoted Standard: JJG 744-2004; GB 9706.1-2007; GB/T 19042.4-2005 Regulation (derived from): People's Republic of China The State Administration of Quality Supervision, Inspection and Quarantine Notice 2014 (No. 95); AQSIQ Notice 2014 No. 95 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This Standard applies to medical diagnosis panoramic dental X-ray radiation in the initial verification, verification and subsequent use of checks. This Standard does not apply to intra-oral X-ray imaging device calibration of radiation sources. JJG 1101-2014: Verification Regulation of Medical Diagnostic X-ray Source for Dental Panorama---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Regulation of Medical Diagnostic X-ray Source for Dental Panorama State verification procedures People's Republic of China Medical Diagnostic panoramic dental X-ray radiation source Issued on. 2014-08-25 2014-11-25 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Medical Diagnostic panoramic dental X-ray radiation source Verification Regulation Focal point. the National Technical Committee of ionizing radiation metrology The main drafting units. China Testing Technology Research Institute Fujian Institute of Metrology Participated in the drafting unit. Shanghai Institute of Measurement and Testing Xinjiang Institute of Metrology Ankang City, Shaanxi measurement test This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this procedure. Yang Gan (China Testing Technology Research Institute) Li Jie (Fujian Institute of Metrology) Yang (China Testing Technology Research Institute) Drafters participate. Lu Xun (Shanghai Institute of Measurement and Testing) Feng Xuefeng (Xinjiang Institute of Measurement and Testing) Wang Bin (Shaanxi Ankang City metering test) table of ContentsIntroduction (Ⅱ) 1 Scope (1) 2. References (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (2) 4 Overview (2) 5 metering performance requirements (2) 5.1 air kerma rate (2) Repeatability 5.2 radiation output (2) 5.3 Quality radiation output (2) 5.4 voltage (2) 5.5 Spatial resolution (2) 5.6 low contrast resolution (2) 5.7 Exposure Time (2) 6 General Requirements (2) 6.1 Appearance and flags (2) 6.2 electrical, mechanical and barrier properties (3) 7 control of measuring instruments (3) 7.1 test conditions (3) 7.2 Verification Project (3) 7.3 Verification Methods (4) 7.4 Verification Results Processing (5) 7.5 test cycle (5) Appendix A test original records (recommended) formatting styles (6) Appendix B test certificates/test results in the notice page (recommended) formatting styles (7) Appendix C measuring layout and dental mold body (10)IntroductionThis procedure based on JJF1002-2010 "national verification procedures writing rules" and JJF1001-2011 "Tong Metering term and definition of "establishment. Metrological characteristics and test methods panoramic dental X-ray radiation source with reference to the GB/T 19042.4-2005 / IEC 61223-3-4.2000 "evaluation of medical imaging departments and routine testing - Part 3-4. dental X-ray set Imaging equipment performance acceptance test "and JJG 744-2004" Medical Diagnostic X-ray radiation "set forth in the respective Provisions. This procedure was first formulated. Medical Diagnostic panoramic dental X-ray radiation source verification procedures1 ScopeThe order applies to medical diagnostic panoramic dental X-ray radiation source initial verification, verification and subsequent use an examination. This procedure does not apply to intraoral X-ray imaging apparatus of the radiation source verification. 2. References This procedure references the following documents. JJG 744-2004 diagnostic X-ray radiation GB 9706.1-2007/IEC 60601-1. 1988 Medical electrical equipment - Part 1. General requirements for safety GB/T 19042.4-2005/IEC 61223-3-4.2000 Evaluation and routine medical imaging departments test Part 3-4. Dental X-ray imaging equipment performance acceptance tests For dated references, only the dated edition applies to this procedure; undated reference documents Member, the latest edition (including any amendments) applies to this procedure.3 terminology and units of measurement3.1 Terms 3.1.1 Air Kerma airkerma The sum of the initial kinetic energy of the ionized particles in the uncharged mass dm of air released from all of the charged particles dEtr divided dm, symbol K. K = dEtr dm 3.1.2 air kerma rate airkermarate Dt increase the amount of time in the air kerma dK divided by dt, symbol K dK dt 3.1.3 Spatial resolution spatialresolution In the images under high contrast conditions can distinguish between two adjacent objects ability. 3.1.4 Low contrast resolution lowcontrastresolution And the ability to distinguish between homogeneous mass of low contrast objects. 3.1.5 half-value layer half-valuelayer Will reduce the amount of radiation particles unidirectional flow to decrease the thickness of the initial value of half time, the symbol for the HVL. 3.1.6 tube voltage tubevoltage Is applied between the X-ray tube anode and cathode potential difference. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1101-2014_English be delivered?Answer: Upon your order, we will start to translate JJG 1101-2014_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 1101-2014_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1101-2014_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |