JJG 1077-2012 English PDFUS$349.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1077-2012: Verification Regulation of Ozone Gas Analyzers Status: Valid
Basic dataStandard ID: JJG 1077-2012 (JJG1077-2012)Description (Translated English): Verification Regulation of Ozone Gas Analyzers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A61 Classification of International Standard: 17.020 Word Count Estimation: 15,168 Regulation (derived from): State Administration of Quality Supervision, Inspection and Quarantine Notice 2012 No. 63; Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to air or other gas composition measurements of ozone concentration ozone gas analyzer (hereinafter referred to as "equipment") of the initial verification, testing and use of follow-up checks. JJG 1077-2012: Verification Regulation of Ozone Gas Analyzers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification Regulation of Ozone Gas Analyzers State verification procedures People's Republic of China Ozone gas analyzer Issued on. 2012-04-17 2012-07-17 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Ozone gas analyzer Verification Regulation OzoneGasAnaly zers Focal point. the National Technical Committee on Environment stoichiometry The main drafting units. China Institute of Metrology Participated in the drafting. Changqing Computer Application Companies Beijing Kanger-Technology Development Co., Ltd. This procedure commissioned the National Technical Committee of the stoichiometric environment responsible for interpreting The main drafters of this procedure. Zhouze Yi (China Institute of Metrology) Drafters participate. Qinyan Chang Changqing Computer Application Companies Sun Haiyan Beijing Kanger-Technology Development Co., Ltd. table of ContentsIntroduction (Ⅱ) 1 Scope (1) 2 Overview (1) 3 metering performance requirements (1) 3.1 indication error (1) 3.2 Repeatability (1) 3.3 Response Time (1) 3.4 zero drift and span drift (1) 4 General Requirements (1) 4.1 appearance and energizing check (1) 4.2 Insulation Resistance (2) 4.3 dielectric strength (2) 5 control of measuring instruments (2) 5.1 verification Conditions (2) 5.2 Calibration with standard appliances and equipment (2) 5.3 Verification Project (2) 5.4 Verification Methods (3) 5.5 Verification Results Processing (5) 5.6 test cycle (5) Appendix A calibration certificate/test results in the notice page format (6) Appendix B test recording format (9)IntroductionThis procedure is based on JJF1002-2010 "national verification procedures write rules", JJF1001 "general purpose Volume terms and definitions "and JJF1059" Evaluation and Expression of Uncertainty in Measurement "provisions enacted. The procedures include the subject of the instrument are. the use of ozone gas applications for environmental monitoring, research and analysis, and chemical analyzer Tester ozone gas and ozone alarm chemical industry, disease prevention and control, pollution control and other industries use. Range can be From (10-9 ~ 10-4) mol/mol. The rules of verification of the main metering projects are. --- Indication error in the relative error of the measured value representation; --- Relative standard deviation of repeatability of measurements indicated; --- To measure the response time is the time required to stabilize the value of 90% representation; --- Full scale (FS) relative error represented stability, including stability zero drift and span drift. The main criteria of the present rules of order are. --- Ozone standard gas generator. Yes (0 ~ 1) μmol/mol range, the maximum permissible absolute error is less More than 2.0%; for ( > 1 ~ 400) μmol/mol range, not the absolute value of the maximum permissible error At 5.0%. --- Because ozone is an extremely lively and strong oxidizing gas can not be stored in cylinders or containers, only dynamic It happens now with the current. This procedure is the first national verification procedures developed. Ozone gas analyzer test procedures1 ScopeThe order applies to the measurement of air or other gas components in the ozone content of the ozone gas analyzer (hereinafter referred to as "Instrument") of the initial verification, use and subsequent verification check.2 OverviewInstrument detection principle generally include UV absorption principle, the principle of electrochemical sensors, semiconductor gas sensor original Physical and chemical principles of discoloration. By sampling methods are inhaled and spread two. General Instrument by the sampling device, sensing module Block, electronic circuits, displays and other components. Component being tested by the sensor into electrical signals, and then by electronic circuitry Into a digital signal showing the concentration of ozone.3 metering performance requirements3.1 Indication error Indication error should meet the requirements of Table 1. Table 1 shows the error Range Range (R *, μmol/mol) indication error 0.10 \u003cR≤1.00 ±6%FS 1.00 \u003cR≤400 ±12%FS * R range for the instrument; FS. full scale instrument. 3.2 Repeatability Not more than 2% repeatability. 3.3 Response Time Inhaled Sampling Method instrument response time of less than 60s; diffusion Sampling Method instrument response time Not more than 180s. 3.4 zero drift and span drift 3.4.1 Zero Drift For fixed equipment, continuous operation 4h, zero drift should not exceed ± 1% FS. For non-fixed instruments without Claim. 3.4.2 Span drift For fixed equipment, continuous operation 4h, span drift should not exceed ± 2% FS. For non-fixed instruments without Claim.4 General technical requirements4.1 appearance and power check ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1077-2012_English be delivered?Answer: Upon your order, we will start to translate JJG 1077-2012_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 1077-2012_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1077-2012_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |