JJG 1068-2011 English PDFUS$419.00 ยท In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJG 1068-2011: Verification regulation of DC reference standard Status: Valid
Basic dataStandard ID: JJG 1068-2011 (JJG1068-2011)Description (Translated English): Verification regulation of DC reference standard Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A55 Classification of International Standard: 17.220 Word Count Estimation: 18,173 Date of Issue: 2011-06-14 Date of Implementation: 2011-09-14 Regulation (derived from): AQSIQ Announcement No. 90 of 2011 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to the output DC voltage is 1V, 1. 018V, 10V solid state voltage standard initial verification, testing and use of follow-up checks. JJG 1068-2011: Verification regulation of DC reference standard---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Verification regulation of DC reference standard State verification procedures People's Republic of China Solid-state voltage standard Issued on. 2011-06-14 2011-09-14 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Solid-state voltage standard test procedures VerificationReg The regulations by the State Administration of Quality Supervision, Inspection and Quarantine on June 14, 2011, approved and since From September 14, 2011 into effect. Focal point. the National Technical Committee on Electromagnetic measurement Drafted by. China Aerospace Science and Industry Corporation Second Hospital 203 China Aerospace Science and Technology Group of the five branches of 514 The measurement procedure commissioned the National Technical Committee is responsible for interpreting electromagnetic The main drafters of this procedure. Wang Lu (China Aerospace Science and Industry Corporation hospital 203) Kang Yan (China Aerospace Science and Industry Corporation hospital 203) Zhao Zhi (China Aerospace Science and Technology Group of the five branches of 514) Drafters participate. Hu Yifei (China Aerospace Science and Industry Corporation hospital 203) Small yellow nails (five branches of China Aerospace Science and Technology Group 514) table of Contents1 Scope (1) 2 Terms (1) 3 Overview (1) 4 metering performance requirements (1) 4.1 stability of the output voltage (1) 4.2 Common-scale output voltage of the allowable range (2) 5 General Requirements (2) 5.1 Appearance and accessories (2) 5.2 check work (2) 6 Control of measuring instruments (2) 6.1 Verification condition (2) 6.2 test items and test methods (3) 6.3 Verification Results Processing (8) 6.4 test cycle (8) Appendix A calibration certificate and test results of notice (in-plane) format (9) B divider and calibration method refers to the zero meter appendix (11) Solid-state voltage standard test procedures1 ScopeThe order applies to the DC output voltage is 1V, 1.018V, 10V voltage standard solid initial verification, Use and subsequent verification check.2 TermsJapanese drift rate driftrate Within a period of change in output voltage divided by the number of days included in the period.3 OverviewStandard solid-state voltage as a DC voltage standard for test/calibration of high accuracy and versatility of digital voltmeter Calibration, etc., can also be saved daily DC voltage value. Voltage standard solid core element is a Zener diode, it is divided into discrete zener diode solid-state voltage standard Type solid-state amplifiers and reference voltage standard. Generally solid state voltage standard output voltages are designed to 10V, 1.018V and its output is 1V Through the 10V reference voltage divider obtained, shown in Figure 1. Figure 1 Schematic solid state voltage standard Vz- warm padded Zener diode; N- integrated amplifier4 metering performance requirements4.1 output voltage stability Solid-state voltage stability standard output voltage are shown in Table 1. ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1068-2011_English be delivered?Answer: Upon your order, we will start to translate JJG 1068-2011_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 1068-2011_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1068-2011_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |