JJG 1051-2021: (Electrolyte Analyzer Verification Regulations)
Status: Valid

JJG 1051: Historical versions

Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJG 1051-2021439 Add to Cart 5 days (Electrolyte Analyzer Verification Regulations) Valid
JJG 1051-2009719 Add to Cart 3 days Verification Regulation for Electrolyte Analyzers Obsolete
JJG 1051-1996RFQ ASK 3 days Designation for Working Measuring Instrument and its Classification Code Obsolete

Similar standards

JJG 1022   JJG 1094   JJG 975   JJG 1061   JJG 1060   JJF 1051   

Basic data

Standard ID: JJG 1051-2021 (JJG1051-2021)
Description (Translated English): (Electrolyte Analyzer Verification Regulations)
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A61
Word Count Estimation: 22,23
Issuing agency(ies): State Administration for Market Regulation

JJG 1051-2021: (Electrolyte Analyzer Verification Regulations)

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Electrolyte Analyzer Verification Regulations) People's Republic of China National Metrological Verification Regulations Electrolyte Analyzer 2022-01-28 Implementation Released by the State Administration for Market Regulation Electrolyte analyzer verification procedures Replacing JJG 1051-2009 Focal Point. National Clinical Medicine Metrology Technical Committee Drafting unit. Heilongjiang Provincial Institute of Metrology, Verification and Testing Shenzhen Kite Biomedical Electronic Technology Co., Ltd. This regulation is entrusted to the National Clinical Medicine Metrology Technical Committee to be responsible for the interpretation The drafters of this regulation. Ding Haiming (Heilongjiang Institute of Metrology, Verification and Testing) Wu Guoqiang (Shenzhen Kate Biomedical Electronic Technology Co., Ltd.)

content

Introduction (Ⅱ) 1 Scope(1) 2 References (1) 3 Terms (1) 4 Overview(1) 5 Measurement performance requirements (2) 6 General technical requirements (2) 7 Measuring Instrument Control(2) 7.1 Verification Conditions (2) 7.2 Verification items and verification methods (3) 7.3 Processing of Verification Results (6) 7.4 Verification Period(6) Appendix A Calculation of Slope and Intercept in Linear Regression(7) Appendix B Preparation method of standard solution for verification (8) Appendix C Verification Record Format (10) Appendix D Verification Certificate/Inner Page Format of Verification Result Notification (15)

Introduction

This regulation is compiled in accordance with JJF1002-2010 "Rules for Compilation of National Metrological Verification Regulations". This regulation is for Revision of JJG 1051-2009 "Electrolyte Analyzer". Compared with JJG 1051-2009, except for editorial changes, The main technical changes are as follows. --- The term "cross-contamination rate" is changed to "carry-over contamination rate" (see Chapter 3); --- Added the relevant content of Li and iCa2 (see Chapter 5); --- Modified the indication error requirements of K, Na, Cl- (see Chapter 5); ---Appendix B adds the preparation method of Li, iCa2 linear solution. The previous versions of this regulation have been released as follows. ---JJG 1051-2009. Electrolyte analyzer verification procedures

1 Scope

This regulation applies to the use of ion-selective electrode method to determine the concentration of K, Na, Cl-, Li, iCa2 in medical Initial verification, subsequent verification and in-use inspection of electrolyte analyzers.

2 Reference documents

GB/T 14710-2009 Environmental requirements and test methods for medical electrical appliances GB/T 6682-2008 Specifications and test methods for water used in analytical laboratories YY/T 0589-2016 Electrolyte Analyzer For dated references, only the dated version applies to this regulation; for undated references The latest version (including all amendments) applies to this regulation.

3 Terminology

3.1 Carry-overrate The discrete amount of analyte carried by the measurement system from one test sample reaction to another test sample reaction, determined by This erroneously affects the performance of another test sample. Usually given a low value sample and a high value of a known nominal setting Value samples are cross-measured multiple times and calculated using a specific formula.

4 Overview

The electrolyte analyzer adopts the ion-selective electrode method. The battery potential formed by the specific electrode is used to measure the ionic activity in the electrolyte solution. Cell potential and specific ionization in solution The relationship of the sub-activity conforms to the Nernst equation. E=E0± RT nFlnαx (1) αx=fx·cx (2) where. E---Measure battery potential, mV; E0---Measure the initial potential value of the battery, mV; R---gas constant, 8.3145J/(K mol); T---thermodynamic temperature of the solution to be tested, K; n---the valence of the tested ion participating in the electrode reaction; F---Faraday constant, 96485C/mol; αx---the activity of the measured ion, mol/L; fx---activity coefficient;
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJG 1051-2021_English be delivered?

Answer: Upon your order, we will start to translate JJG 1051-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 3 ~ 5 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJG 1051-2021_English with my colleagues?

Answer: Yes. The purchased PDF of JJG 1051-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.

Question 5: Should I purchase the latest version JJG 1051-2021?

Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1051-2021 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically.