JJG 1026-2007 English PDFJJG 1026: Historical versions
Basic dataStandard ID: JJG 1026-2007 (JJG1026-2007)Description (Translated English): Verification Regulation of Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography(CT) Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A58;C43 Classification of International Standard: 11.040.50 Word Count Estimation: 20,271 Date of Issue: 2007-08-02 Date of Implementation: 2007-11-02 Quoted Standard: GB 3100-1993; GB 3101-1993; GB 3102-1993; GB/T 17006-1997; GB/T 10149-1988; GB/T 17589-1998; GB 9706.18-2000; IEC 61223-3-5; IEC 60601 -2-44; IEC 61223-2-6 Regulation (derived from): AQSIQ Announcement No. 142 of 2007 Issuing agency(ies): General Administration of Quality Supervision, Inspection and Quarantine Summary: This standard applies to new installations, the use and impact of the imaging properties of the parts after repair of medical diagnostic devices spiral computed radiography (CT) X-ray radiation source verification. JJG 1026-2007: Verification Regulation of Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography(CT)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order. Verification Regulation of Medical Diagnostic X-ray Radiation Source for Spiral Computed Tomography (CT) State verification procedures People's Republic of China Medical Diagnostic spiral computed tomography apparatus (CT) X-ray radiation source ComputedTomography (CT) Posted 2007-08-02 2007-11-02 implementation The State Administration of Quality Supervision, Inspection and Quarantine released Medical Diagnostic spiral computed tomography apparatus (CT) X-ray radiation source verification procedures ComputedTomography (CT The regulations by the State Administration of Quality Supervision, Inspection and Quarantine approved on August 2, 2007, and from From November 2, 2007 implementation. Focal point. the National Technical Committee of ionizing radiation metrology Drafting. Beijing Institute of Metrology detection Xuanwu Hospital Participating units. Beijing Siemens Technology Development Co., Ltd. Three wide-cum-medical Toshiba Medical This procedure commissioned the National Technical Committee is responsible for ionizing radiation measurement interpretation The main drafters of this procedure. Tao (Beijing Institute of Metrology detection) Pengming Chen (Xuanwu Hospital) Drafters participate. Liang Shaohua (Beijing Siemens Technology Development Co., Ltd.) Liu Yong (three wide-cum-medical Toshiba Medical) Zhang Ying (Beijing Institute of Metrology detection) Bai Mei (Institute of Hospital Management Clinical Engineering Technology Research heart) Pengyong Lun (Beijing Institute of Metrology detection) table of Contents1 Scope (1) 2. Referenced Documents (1) 3 terminology and units of measurement (1) 3.1 The term (1) 3.2 units of measurement (3) 4 Overview (4) 5 metering performance requirements (4) 5.1 dose index (4) Uniformity 5.2 (4) Noise level 5.3 (4) 5.4 Consistency between images (5) 5.5 CT value (5) 5.6 thickness (5) 5.7 Spatial resolution (rate) (5) 5.8 low contrast resolution (rate) (5) 6 General technical conditions (6) 7 control of measuring instruments (6) 7.1 test conditions (6) 7.2 test items and test methods (6) 7.3 test results processing (10) 7.4 test cycle (10) A medical diagnostic device spiral computed tomography (CT) X-ray radiation test records appendix (11) Appendix B test certificate-page format (12) Appendix C helical scan tomographic slice thickness (13) Appendix D schematic detector spiral CT phantom (14) Medical Diagnostic spiral computed tomography apparatus (CT) X-ray radiation source verification procedures1 ScopeThe test procedures for new installations, the use and impact of the imaging properties of the parts repaired medical diagnostic spiral meter Computer imaging means (CT) X-ray radiation source verification.2 CitationsThe regulations cited in the following documents. [1] GB 3100 ~ 3102-1993 "Quantities and units" [2] GB/T 17006-1997 "evaluation in medical imaging departments and routine testing - Part 2-6. X-ray meter Operator body tomography equipment Stability Test " [3] GB/T 10149-1988 "X-ray equipment for medical terminology and symbols." [4] GB/T 17589-1998 "X-ray computed tomography apparatus Image quality assurance test specification" [5] GB 9706.18-2000 "Medical electrical equipment Part. X-ray computed tomography apparatus security Full-specific requirements " [6] IEC 61223-3-5EvaluationandRoutineTestingin MedicalImagingDepart- ments-Part 3-5. Acceptancetests --- ImagingPerformanceofComputedTomography X- rayequipment [7] IEC 60601-2-44 Medical Electrical Equipment --- Part 2-44. Particular RequirementsfortheSafetyofX-rayEquipmentforComputedTomography [8] IEC 61223-2-6Ed.2 --- CDV EvaluationandRoutineTestingin Medical ImagingDepartmentsPart 2-6Ed.2. ConstancyTests-ImagingPerformanceofComputed TomographyX-rayEquipment [9] Europeanguidelinesonqualitycriteriaforcomputedtomography2002-7-27 When using this procedure, it should pay attention to using the currently valid version of the documents cited.3 terminology and units of measurement3.1 Terms 3.1.1 Dose Index doseindex 3.1.1.1 CT dose index 100 (CTDI100) To produce a single axial scan along a line perpendicular to the plane layer dose distribution from -50mm to 50mm of Points divided by the number of slices N layer and a layer of nominal slice thickness T of the product. CTDI100 = ∫ 50mm -50mm D (z) N · Tdz (1) Where. D (z) --- along a line perpendicular to the plane dose layer distribution of the z-axis (z = 0 in the center), this sub-dose ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJG 1026-2007_English be delivered?Answer: Upon your order, we will start to translate JJG 1026-2007_English as soon as possible, and keep you informed of the progress. The lead time is typically in 9 seconds (download/delivered in 9 seconds). The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJG 1026-2007_English with my colleagues?Answer: Yes. The purchased PDF of JJG 1026-2007_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.Question 5: Should I purchase the latest version JJG 1026-2007?Answer: Yes. Unless special scenarios such as technical constraints or academic study, you should always prioritize to purchase the latest version JJG 1026-2007 even if the enforcement date is in future. Complying with the latest version means that, by default, it also complies with all the earlier versions, technically. |