JJF 2078-2023 English PDFUS$689.00 · In stock
Delivery: <= 6 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 2078-2023: Calibration Specification for Real-time Spectrum Analyzers Status: Valid
Basic dataStandard ID: JJF 2078-2023 (JJF2078-2023)Description (Translated English): Calibration Specification for Real-time Spectrum Analyzers Sector / Industry: Metrology & Measurement Industry Standard Word Count Estimation: 34,341 Date of Issue: 2023-10-12 Date of Implementation: 2024-04-12 Issuing agency(ies): State Administration for Market Regulation JJF 2078-2023: Calibration Specification for Real-time Spectrum Analyzers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.National Metrology Technical Specifications of the People's Republic of China Real-time Spectrum Analyzer Calibration Specifications Released on 2023-10-12 Implemented on 2024-04-12 Released by the State Administration for Market Regulation Real-time Spectrum Analyzer Calibration Specifications Responsible unit: National Radio Measurement Technical Committee Main drafting unit: China Institute of Metrology Shanghai Institute of Metrology and Testing Technology Measurement and Testing Center of China Academy of Engineering Physics Unit participating in the drafting: Shanghai Xinwen Technology Co:, Ltd: The National Radio Measurement Technical Committee is entrusted with the interpretation of this specification: The main drafters of this specification: He Zhao (China Institute of Metrology) Zhan Zhiqiang (Shanghai Institute of Metrology and Testing Technology) Wang Jianzhong (Measurement and Testing Center of China Academy of Engineering Physics) Wei Zhu (Measurement and Testing Center of China Academy of Engineering Physics) Participating drafters: Nie Mening (Chinese Institute of Metrology) Zhang Rui (Measurement and Testing Center of China Academy of Engineering Physics) Chen Gang (Shanghai Xinwen Technology Co:, Ltd:) Table of contentsIntroduction(Ⅱ) 1 Scope(1) 2 Cited documents(1) 3 terms(1) 4 Overview(2) 5 Measuring characteristics(2) 5:1 Maximum real-time analysis bandwidth(2) 5:2 Real-time analysis bandwidth(2) 5:3 Full amplitude accuracy at full capture of minimum pulse width(2) 5:4 Amplitude ratio of different signal template ratios when fully capturing the minimum pulse width (2) 5:5 Frequency mask trigger level(2) 5:6 Spurious-free dynamic range(2) 5:7 In-band frequency response(2) 5:8 Reference frequency(2) 5:9 Frequency response(3) 6 Calibration conditions(3) 6:1 Environmental conditions(3) 6:2 Measurement standards(3) 7 Calibration items and calibration methods (4) 7:1 Appearance and working normality inspection (4) 7:2 Maximum real-time analysis bandwidth(4) 7:3 Real-time analysis bandwidth(5) 7:4 Amplitude ratio at full capture of minimum pulse width (5) 7:5 Amplitude ratio of different signal template ratios when fully capturing the minimum pulse width (7) 7:6 Frequency mask trigger level(7) 7:7 Spurious-free dynamic range(9) 7:8 In-band frequency response(9) 7:9 Reference frequency accuracy(10) 7:10 Frequency response(11) 8 Expression of calibration results(11) 9 Re-schooling time interval(12) Appendix A Original record inner page format (13) Appendix B Calibration Certificate Inner Page Format (16) Appendix C Example of calibration uncertainty assessment of major items (19)IntroductionJJF 1071-2010 "Rules for Writing National Measurement Calibration Specifications" and JJF 1059:1-2012 "Measurement Uncertainty" Assessment and Expression" together constitute the basic series of specifications that support the preparation of this specification: This specification is released for the first time: Real-time Spectrum Analyzer Calibration Specifications1 ScopeThis specification is applicable to real-time spectrum analyzers and real-time spectrum in spectrum analyzers with a frequency range of 3Hz~50GHz: Calibration of the analysis module, calibration of real-time spectrum analyzers and real-time spectrum analysis modules in other frequency ranges can be referred to implement:2 cited documentsThis specification references the following documents: JJF 1396 Spectrum Analyzer Calibration Specifications For dated references, only the dated version applies to this specification; for undated references, only the dated edition applies: The latest version (including all modification orders) shall apply to this specification:3 termsReal-time spectrum analyzer captures 100% of the narrowest pulse duration: 100% amplitude accuracy When the pulse width of the input signal goes from wide to narrow, the difference between the signal amplitude and the amplitude in the continuous wave state: The rms amplitude of the ADC (analog-to-digital converter) carrier frequency (maximum signal component) within the real-time analysis bandwidth The ratio of the root mean square value of the maximum noise component, usually expressed in dBc (relative to the carrier frequency amplitude) or dBFS (relative to the carrier frequency amplitude) expressed in the full-scale range of the ADC): 3:4 Waterfall chart spectrum time frequency diagram Spectrogram A display mode of a real-time spectrum analyzer, in which frequency is represented by the x-axis, time is represented by the y-axis, and power is represented by Indicated by color: Corresponds to the digitizer and IF bandwidth of the real-time spectrum analyzer, enabling seamless real-time capture of frequencies rate span: Note: The real-time analysis bandwidth of a real-time spectrum analyzer is similar to the sweep width of a swept frequency spectrum analyzer: In the frequency domain of a real-time spectrum analyzer, a triggering method uses a preset frequency-amplitude threshold as the trigger condition: Amplitude-frequency characteristics within the maximum real-time analysis bandwidth: ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 2078-2023_English be delivered?Answer: Upon your order, we will start to translate JJF 2078-2023_English as soon as possible, and keep you informed of the progress. The lead time is typically 4 ~ 6 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 2078-2023_English with my colleagues?Answer: Yes. The purchased PDF of JJF 2078-2023_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |