JJF 1910-2021: (Calibration specification for electrochemical workstation)
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1910-2021359 Add to Cart 4 days (Calibration specification for electrochemical workstation) Valid

Similar standards

JJF 1424   JJF 1441   JJF 1363   JJF 1916   JJF 1891   JJF 1907   

Basic data

Standard ID: JJF 1910-2021 (JJF1910-2021)
Description (Translated English): (Calibration specification for electrochemical workstation)
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A61
Word Count Estimation: 18,139
Issuing agency(ies): State Administration for Market Regulation

JJF 1910-2021: (Calibration specification for electrochemical workstation)

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
(Calibration specification for electrochemical workstation) National Metrology Technical Specification of the People's Republic of China Electrochemical Workstation Calibration Specifications Published on 2021-07-28 2022-01-28 Implementation Released by the State Administration for Market Regulation Electrochemical Workstation Calibration Specifications Focal Point. National Biometric Technology Committee Main drafting unit. Shanghai Institute of Metrology and Testing Technology Participating in the drafting unit. China Institute of Metrology This specification is entrusted to the National Biometric Technology Committee to be responsible for the interpretation The main drafters of this specification. Gang Liu (Shanghai Institute of Metrology and Testing Technology) Li Lanying (Shanghai Institute of Metrology and Testing Technology) Wang Lele (Shanghai Institute of Metrology and Testing Technology) Participating drafters. Wu Liqing (China Institute of Metrology) Yang Bin (China Institute of Metrology)

content

Introduction (Ⅱ) 1 Scope(1) 2 References (1) 3 Terms (1) 3.1 Working electrode(1) 3.2 Reference electrode(1) 3.3 Auxiliary electrode(1) 4 Overview(1) 5 Metrology Characteristics(1) 6 Calibration Conditions(2) 6.1 Environmental conditions (2) 6.2 Instruments and reagents for calibration (2) 7 Calibration items and calibration methods (2) 7.1 Potential indication error (2) 7.2 Current indication error(3) 7.3 Spike repeatability(3) 8 Expression of calibration results (4) 9 Recalibration interval(4) Appendix A Glassy Carbon Electrode Pretreatment Method (5) Appendix B Preparation Method of Electrochemical Workstation Calibration Solution(6) Appendix C Calibration Record Reference Format(7) Appendix D Example of Uncertainty Evaluation of Indication Error Measurement Results (9) APPENDIX E RECOMMENDED FORM OF INNER PAGE OF CALIBRATION CERTIFICATE(12)

Introduction

JJF 1071 "Rules for the Compilation of National Metrology Calibration Specifications", JJF 1001 "General Metrology Terms and Definitions" and JJF 1059.1 "Assessment and Representation of Measurement Uncertainty" together constitute the basic series of regulations supporting the formulation of this specification. Fan. This specification is compiled with reference to YY/T 1074-2002 "Pitting Corrosion Potential of Stainless Steel Products for Surgical Implants". This specification is published for the first time. Electrochemical Workstation Calibration Specifications

1 Scope

This specification applies to the analysis of the electrochemical properties of substances, equipped with a three-electrode system, with potentiostatic and cyclic voltammetry calibration of the electrochemical workstation.

2 Reference documents

This specification references the following documents. JJF 1059.1-2012 Evaluation and representation of measurement uncertainty YY/T 1074-2002 Pitting corrosion potential of stainless steel products for surgical implants For dated references, only the dated version applies to this specification; for undated references files, the latest version of which applies to this specification.

3 Terminology

3.1 Working electrode workingelectrode Electrodes to be studied and measured in electrochemical systems. 3.2 Reference electrode referenceelectrode An electrode with a stable repetitive potential value can use its potential value as a reference potential to measure the potential of other electrodes. potential value. 3.3 auxiliary electrode auxiliaryelectrode Another electrode used to energize the working electrode.

4 Overview

The electrochemical workstation is a multifunctional electrochemical analysis system, which can accurately control the electrochemical reaction potential and According to different methods, changes in signal parameters such as current are detected. There are many kinds of analysis methods, and the commonly used analysis methods are. Cyclic voltammetry, AC voltammetry, amperometric titration and potentiometric titration, etc. Instruments typically consist primarily of fast digital signals generator, high-speed data acquisition system, potential current signal filter, multi-stage signal gain, IR drop compensation circuit, etc. And potentiostat, galvanostat and other components.

5 Metrology characteristics

The electrochemical workstation calibration items and technical indicators are shown in Table 1.
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1910-2021_English be delivered?

Answer: Upon your order, we will start to translate JJF 1910-2021_English as soon as possible, and keep you informed of the progress. The lead time is typically 2 ~ 4 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1910-2021_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1910-2021_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.