Home Cart Quotation About-Us
www.ChineseStandard.net
SEARCH

JJF 1875-2020 English PDF

US$329.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email.
JJF 1875-2020: Calibration Specification for On-line Automatic Monitors of Permanganate Index
Status: Valid
Standard IDUSDBUY PDFLead-DaysStandard Title (Description)Status
JJF 1875-2020329 Add to Cart 3 days Calibration Specification for On-line Automatic Monitors of Permanganate Index Valid

Similar standards

JJF 1424   JJF 1441   JJF 1363   JJF 1891   JJF 1873   JJF 1869   

Basic data

Standard ID: JJF 1875-2020 (JJF1875-2020)
Description (Translated English): Calibration Specification for On-line Automatic Monitors of Permanganate Index
Sector / Industry: Metrology & Measurement Industry Standard
Classification of Chinese Standard: A61
Classification of International Standard: 17.020
Word Count Estimation: 14,140
Date of Issue: 2020-11-26
Date of Implementation: 2021-05-26
Regulation (derived from): Announcement No. 57 (2020) of the State Administration for Market Regulation
Issuing agency(ies): State Administration for Market Regulation
Summary: This standard is applicable to the calibration of the online automatic monitor of permanganate index.

JJF 1875-2020: Calibration Specification for On-line Automatic Monitors of Permanganate Index

---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.
Calibration Specification for On-line Automatic Monitors of Permanganate Index National Metrology Technical Specifications of the People's Republic of China Calibration Specification for Online Automatic Monitor of Permanganate Index 2020-11-26 release 2021-05-26 implementation Issued by the State Administration for Market Regulation Permanganate Index Online Calibration specification for automatic monitor Focal point: National Technical Committee of Physical and Chemical Metrology Online Physical and Chemical Analysis Instrument Sub-Technical Committee Main drafting unit: Jiangsu Institute of Metrology Hebei Institute of Metrology Supervision and Inspection China Institute of Metrology Participated in the drafting: Jiangsu Environmental Monitoring Instrument and Measurement Center Shanxi Institute of Metrology This specification entrusts the Online Physical and Chemical Analysis Instrument Sub-Technical Committee of the National Physical and Chemical Metrology Technical Committee The member will be responsible for explaining The main drafters of this specification: Song Jian (Jiangsu Institute of Metrology) Fang Jing (Hebei Institute of Metrology Supervision and Inspection) Shi Naijie (China Institute of Metrology) Participating drafters: Xing Jinjing (Jiangsu Institute of Metrology) Wang Shaoli (Jiangsu Province Environmental Monitoring Instrument Metrology Center) Li Jun (Shanxi Institute of Metrology)

table of Contents

Introduction (Ⅱ) 1 scope (1) 2 Overview (1) 3 Measurement characteristics (1) 4 Calibration conditions (1) 4:1 Environmental conditions (1) 4:2 Reference materials and calibration equipment (1) 5 Calibration items and calibration methods (2) 5:1 Indication error (2) 5:2 Relative indication error (2) 5:3 Stability (2) 6 Calibration result expression (2) 7 Re-calibration interval (3) Appendix A Reference Format of Calibration Certificate (Inner Page) (4) Appendix B Reference format for calibration record of online automatic monitor of permanganate index (5) Appendix C Uncertainty Evaluation Example of Indication Error and Relative Indication Error (7)

Introduction

This specification is based on JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications", JJF 1001-2011 "General Measurement terms and definitions" and JJF 1059:1-2012 "Measuring Uncertainty Evaluation and Expression" are the basic series of specifications Make it: The formulation of this specification refers to GB/T 11892-1989 "Determination of Water Quality Permanganate Index" and HJ/T 100- 2003 "Technical Requirements for Automatic Water Quality Analyzer for Permanganate Index": This specification is released for the first time: Calibration Specification for Online Automatic Monitor of Permanganate Index

1 Scope

This specification applies to the calibration of the online automatic monitor of permanganate index:

2 overview

The permanganate index online automatic monitor (hereinafter referred to as the instrument) can automatically and continuously monitor surface water, groundwater and Permanganate index in drinking water and other water bodies: The instrument uses the principle of oxidation, adding a known amount of potassium permanganate solution to the water sample, and oxidizing the water under heating The organic matter and reducing inorganic matter in the sample, the oxidized water sample is carried out by redox titration or photoelectric colorimetry After data processing, the permanganate index is directly displayed: The instrument usually consists of sampling, reaction, detection, data processing and transmission and display units:

3 Metrological characteristics

The measurement performance index of the instrument is shown in Table 1: Table 1 Measurement performance indicators Calibration item Technical index ≤5:0mg/L >5:0mg/L 1 The maximum allowable error does not exceed ±0:5mg/L and does not exceed ±10% 2 Stability (12h) ≤5% Note: 1 When the permanganate index of the measuring point is not greater than 5mg/L, the maximum allowable error is expressed by the error of the indication; when the measuring point is high in manganese When the acid salt index is greater than 5mg/L, the maximum allowable error is expressed by the relative indication error: 2 The above indicators are not used for eligibility judgment and are for reference only:

4 Calibration conditions

4:1 Environmental conditions 4:1:1 Ambient temperature: (5~35)℃, the temperature fluctuation during calibration should not exceed ±5℃: 4:1:2 Relative humidity: ≤85%: 4:1:3 There shall be no mechanical vibration and electromagnetic interference that affect the normal operation of the instrument: 4:1:4 Do not store flammable, explosive and highly corrosive substances that are not related to the experiment: 4:2 Reference materials and calibration equipment 4:2:1 Reference material: National certified permanganate index/chemical oxygen demand (manganese method) reference material is used, and its extension The uncertainty is not more than 3% (k=2): 4:2:2 Zero point calibration solution: Add a little potassium permanganate redistilled water to the distilled water (in the
......
Image     

Tips & Frequently Asked Questions:

Question 1: How long will the true-PDF of JJF 1875-2020_English be delivered?

Answer: Upon your order, we will start to translate JJF 1875-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.

Question 2: Can I share the purchased PDF of JJF 1875-2020_English with my colleagues?

Answer: Yes. The purchased PDF of JJF 1875-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.

Question 3: Does the price include tax/VAT?

Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countries

Question 4: Do you accept my currency other than USD?

Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay.