JJF 1836-2020 English PDFUS$279.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1836-2020: Calibration Specification for Micro-spectrophotometers Status: Valid
Basic dataStandard ID: JJF 1836-2020 (JJF1836-2020)Description (Translated English): Calibration Specification for Micro-spectrophotometers Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A60 Word Count Estimation: 12,116 Date of Issue: 2020-07-02 Date of Implementation: 2021-01-02 Regulation (derived from): Announcement No. 29 (2020) of the State Administration for Market Regulation Issuing agency(ies): State Administration for Market Regulation JJF 1836-2020: Calibration Specification for Micro-spectrophotometers---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.Calibration Specification for Micro-spectrophotometers National Metrology Technical Specifications of the People's Republic of China Calibration specification for micro spectrophotometer 2020-07-02 released 2021-01-02 implementation Issued by the State Administration for Market Regulation Calibration specification for micro spectrophotometer Focal point. National Biometrics Technical Committee Main drafting unit. China Institute of Metrology Shanghai Institute of Metrology and Testing Technology Boao Biological Group Co., Ltd. This specification entrusts the National Biometrics Technical Committee to be responsible for the interpretation The main drafters of this specification. Gao Yunhua (China Institute of Metrology) Xu Li (Shanghai Institute of Metrology and Testing Technology) Wu Liqing (China Institute of Metrology) Wang Dong (Boao Biological Group Co., Ltd.) Liang Wen (Shanghai Institute of Metrology and Testing Technology) Li Baolian (Boao Biological Group Co., Ltd.) table of ContentsIntroduction (Ⅱ) 1 scope (1) 2 Reference documents (1) 3 Overview (1) 4 Measurement characteristics (1) 5 Calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Standard substances and reagents for calibration (2) 6 Calibration items and calibration methods (2) 6.1 Indication error (2) 6.2 Repeatability (2) 6.3 Linearity and linear range(3) 7 Calibration result expression (3) 8 Recalibration interval (3) Appendix A Uncertainty Evaluation Example of Indication Error (4) Appendix B Reference Format of Calibration Original Record (6) Appendix C Reference Format of Calibration Certificate (Inner Page) (7)IntroductionThis specification is compiled in accordance with the requirements of JJF 1071-2010 "Rules for the Compilation of National Metrology and Calibration Specifications". JJG178-2007 "Verification Regulations for Ultraviolet, Visible and Near Infrared Spectrophotometers", GB/T 26810-2011 "Visible Spectrophotometer". This specification is released for the first time. Calibration specification for micro spectrophotometer1 ScopeThis specification applies to the calibration of micro-spectrophotometers. For other types of spectrophotometers, refer to this specification.2 Reference documentsThis specification refers to the following documents. JJG178-2007 Verification Regulations for Ultraviolet, Visible and Near Infrared Spectrophotometer GB/T 26810-2011 Visible spectrophotometer For dated reference documents, only the dated version applies to this specification; for undated references The latest version (including all amendments) is applicable to this specification.3 overviewThe volume of the micro spectrophotometer is small and the sample amount is small [(1~2)μL]. It is composed of light source, monochromator, absorption cell, The detector and signal indicating system consist of five parts. The principle is based on the selective absorption of light of different wavelengths and Lambert-Beer (Lambert-Beer) law for quantitative analysis and qualitative identification of substances, commonly used in nucleic acids and proteins Qualitative and quantitative analysis and quantification of bacterial concentration. The mathematical expression of Lambert-Beer law is. When testing, use a pipette to drop (1~2) μL of the sample onto the testing platform, and the instrument will automatically complete the test and display Shows the absorbance value and gives the qualitative and quantitative results of the sample (nucleic acid, protein and fluorescent dye).4 Measurement characteristics4.1 Indication error 4.2 Repeatability 4.3 Linearity and linear range ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1836-2020_English be delivered?Answer: Upon your order, we will start to translate JJF 1836-2020_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1836-2020_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1836-2020_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |