JJF 1754-2019 English PDFUS$359.00 · In stock
Delivery: <= 3 days. True-PDF full-copy in English will be manually translated and delivered via email. JJF 1754-2019: Calibration Specification for Deuterium Lamps Spectral Radiance(250 nm~400 nm) Status: Valid
Basic dataStandard ID: JJF 1754-2019 (JJF1754-2019)Description (Translated English): Calibration Specification for Deuterium Lamps Spectral Radiance(250 nm��400 nm) Sector / Industry: Metrology & Measurement Industry Standard Classification of Chinese Standard: A60 Classification of International Standard: 17.180 Word Count Estimation: 16,190 Date of Issue: 2019 Date of Implementation: 2019-12-27 Issuing agency(ies): State Administration for Market Regulation JJF 1754-2019: Calibration Specification for Deuterium Lamps Spectral Radiance(250 nm~400 nm)---This is a DRAFT version for illustration, not a final translation. Full copy of true-PDF in English version (including equations, symbols, images, flow-chart, tables, and figures etc.) will be manually/carefully translated upon your order.(Calibration specification of spectral radiance deuterium lamp (250nm ~ 400nm)) National Measurement Technical Specification of the People's Republic of China Deuterium lamp spectral radiance (250nm~400nm) Calibration specification (250nm~400nm) 2019-09-27 release 2019-12-27 Implementation Issued by the State Administration of Market Supervision and Administration Deuterium lamp spectral radiance (250nm~400nm) Calibration specification Centralized unit. National Optical Metrology Technical Committee Main drafting unit. China Academy of Metrology Participated in the drafting unit. Zhejiang Institute of Metrology Beijing Academy of Metrology and Testing Science This specification entrusts the National Optical Metrology Technical Committee to interpret The main drafters of this specification. Liu Jinyuan (Chinese Academy of Metrology) Participating drafters. Dai Caihong (Chinese Academy of Metrology) Ma Yao (Zhejiang Institute of Metrology) Zhang Qingxian (Beijing Institute of Metrology and Testing Science) table of ContentsIntroduction (Ⅱ) 1 Scope (1) 2 References (1) 3 Overview (1) 4 Measurement characteristics (2) 4.1 Stability (2) 4.2 Repeatability (2) 4.3 Deuterium lamp spectral radiance (2) 5 Calibration conditions (2) 5.1 Environmental conditions (2) 5.2 Calibration equipment (2) 6 Calibration items and methods (4) 6.1 Stability calibration (4) 6.2 Repeatable calibration (4) 6.3 Calibration of spectral radiance (4) 7 Expression of calibration results (5) 8 Recalibration interval (6) Appendix A Suggested Format for Original Records of Calibration of Deuterium Lamp Spectral Radiance (7) Appendix B. Recommended format of the inner page of the calibration certificate (8) Appendix C Example of uncertainty assessment of the spectral radiance (250nm~400nm) of the deuterium lamp (9)IntroductionThis specification is based on JJF 1001-2011 "General Measurement Terms and Definitions", JJF 1032-2005 "Optical Radiometer Quantitative Terms and Definitions" and JJF 1059.1-2012 "Measurement Uncertainty Evaluation and Expression" together form the supporting book Basic series of norms written by the norms. This specification is the first release. Calibration Specification of Deuterium Lamp Spectral Radiance (250nm~400nm)1 ScopeThis specification is applicable to the calibration of the spectral radiance of deuterium lamps in the wavelength range of (250nm~400nm).2 Reference documentsThis specification refers to the following documents. JJG383 Spectral radiance standard lamp For dated reference documents, only the dated version applies to this specification; for those without date references The latest version (including all amendments) is applicable to this specification.3 OverviewThe deuterium lamp is a gas discharge lamp. The deuterium lamp is classified according to the form of the window and can be divided into end window type deuterium lamp and side window type deuterium lamp. Two kinds. Although each deuterium lamp is different due to different requirements and processing technology, its basic structure and properties Are the same. Because the radiation emitted by the deuterium lamp is mainly concentrated in the ultraviolet band, and has high stability, good reproducibility and longevity The advantages of long life, small size and convenient use make it a commonly used standard radiance transfer standard light in the ultraviolet band source. Figure 1 is a schematic diagram of the structure of the deuterium lamp in two window forms. (a) End window type deuterium lamp Figure 1 Schematic diagram of deuterium lamp structure ......Tips & Frequently Asked Questions:Question 1: How long will the true-PDF of JJF 1754-2019_English be delivered?Answer: Upon your order, we will start to translate JJF 1754-2019_English as soon as possible, and keep you informed of the progress. The lead time is typically 1 ~ 3 working days. The lengthier the document the longer the lead time.Question 2: Can I share the purchased PDF of JJF 1754-2019_English with my colleagues?Answer: Yes. The purchased PDF of JJF 1754-2019_English will be deemed to be sold to your employer/organization who actually pays for it, including your colleagues and your employer's intranet.Question 3: Does the price include tax/VAT?Answer: Yes. Our tax invoice, downloaded/delivered in 9 seconds, includes all tax/VAT and complies with 100+ countries' tax regulations (tax exempted in 100+ countries) -- See Avoidance of Double Taxation Agreements (DTAs): List of DTAs signed between Singapore and 100+ countriesQuestion 4: Do you accept my currency other than USD?Answer: Yes. If you need your currency to be printed on the invoice, please write an email to Sales@ChineseStandard.net. In 2 working-hours, we will create a special link for you to pay in any currencies. Otherwise, follow the normal steps: Add to Cart -- Checkout -- Select your currency to pay. |